{"product_id":"5x00453g01-emerson-relay-output-module-new-original-stock","title":"5X00453G01 Emerson Relay Output Module | New \u0026 Original Stock","description":"\u003ch2\u003eEmerson 5X00453G01 Ovation Series Relay Output Module\u003c\/h2\u003e\n\u003cp\u003eConfigured for signal isolation and load control in Ovation Distributed Control System networks, the \u003cstrong\u003eEmerson 5X00453G01\u003c\/strong\u003e (\u003cstrong\u003e5X00453G01\u003c\/strong\u003e Relay Output Module) provides direct physical\/electrical execution.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e5X00453G01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eEmerson\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.84 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e100 mm x 160 mm x 60 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-20 to +60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Type\u003c\/td\u003e\n\u003ctd\u003eRelay Output Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n\u003ctd\u003eOvation DCS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Rating\u003c\/td\u003e\n\u003ctd\u003e24 VDC digital input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Rating\u003c\/td\u003e\n\u003ctd\u003eRelay output, up to 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Protocols\u003c\/td\u003e\n\u003ctd\u003eEthernet\/IP, Modbus TCP\/IP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Options\u003c\/td\u003e\n\u003ctd\u003ePanel or DIN-rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertifications\u003c\/td\u003e\n\u003ctd\u003eCE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProcess Control \u0026amp; DCS Instrumentation Attributes\u003c\/h3\u003e\n\u003cp\u003eThe module utilizes dedicated channel-to-channel galvanic isolation to completely separate internal logic-side components from field-side electrical interference. This circuit design limits fault propagation during surge events across the 4-20 mA HART loops and discrete field lines. Furthermore, the electronic-to-mechanical relay contact execution maintains signal integrity across distributed nodes by minimizing copper loss and mitigating common-mode noise levels inherent in multi-drop instrument networks.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What are the primary isolation characteristics of the relay contact outputs?\u003c\/p\u003e\n\u003cp\u003eA: The module establishes physical galvanic isolation between the low-voltage internal DCS logic circuits and the 24 VDC external field load circuits, preventing high-voltage transients from feeding back into the system backplane.\u003c\/p\u003e\n\u003cp\u003eQ: Can the 6 A relay outputs handle inductive loads directly without external suppression?\u003c\/p\u003e\n\u003cp\u003eA: While the contacts are rated up to 6 A, external surge suppression (such as flyback diodes for DC loads or RC snubbers for AC loads) is recommended to mitigate arcing and maximize contact longevity when switching inductive field devices.\u003c\/p\u003e\n\u003cp\u003eQ: Is this module hot-swappable during active DCS backplane operations?\u003c\/p\u003e\n\u003cp\u003eA: Hot-swapping must follow standard Emerson Ovation safety protocols. The removal of the module breaks the physical relay loop execution, meaning all connected interlocks and field devices will immediately revert to their de-energized states.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting Orientation and Clearance:\u003c\/strong\u003e Secure the module to a standard 35 mm DIN-rail or flat panel surfaces. Maintain a minimum of 50 mm clearance above and below the module enclosure to permit natural thermal convective dissipation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring Conductors:\u003c\/strong\u003e All field-side discrete wiring must utilize shielded twisted-pair conductors. Strip insulation back 7 mm and torque terminal block screws to the specified manufacturer limits to ensure continuous electrical contact under vibration conditions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShield Grounding:\u003c\/strong\u003e Terminate cable shields strictly at a single point on the designated industrial earth ground busbar. Do not ground both ends of the shield to prevent the formation of ground loops across the DCS node.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Emerson","offers":[{"title":"Default Title","offer_id":43824382902371,"sku":"5X00453G01","price":350.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/53_0351aae4-c40a-415d-8efd-83157ed130c7.jpg?v=1762508988","url":"https:\/\/www.autocontrolglobal.com\/products\/5x00453g01-emerson-relay-output-module-new-original-stock","provider":"AutoControl Global","version":"1.0","type":"link"}