{"product_id":"63-slave-devicenet-master-ge-fanuc-90-30-ic693dnm200","title":"63-Slave DeviceNet Master | GE Fanuc 90-30 IC693DNM200","description":"\u003ch3\u003e\u003cstrong\u003eProduct Overview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eGE Fanuc IC693DNM200\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eacts as the primary\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eDeviceNet Master\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003einterface for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSeries 90-30\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePACSystems RX3i\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ePLC platforms. This\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eoriginal module enables the controller to communicate with and manage up to 63 DeviceNet slave devices, such as motor starters, variable frequency drives (VFDs), and remote I\/O blocks. By occupying a single slot in the PLC backplane, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIC693DNM200\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efacilitates high-speed, deterministic data exchange across industrial fieldbus networks, supporting complex automation architectures that require high-throughput I\/O connectivity.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eTechnical Details\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eIC693DNM200\u003c\/strong\u003e \/ \u003cstrong\u003eIC693DNM200-BD\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProtocol\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDeviceNet Master\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSlave Capacity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUp to 63 DeviceNet Slaves\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCommunication Speeds\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e125K, 250K, and 500K Baud\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eI\/O Connections\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2 I\/O connections per slave\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eData Transfer (per Slave)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e255 Input Bytes \/ 255 Output Bytes\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTotal Data Capacity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3972 Input Bytes \/ 3972 Output Bytes\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInterfaces\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOne (1) DeviceNet Terminal; One (1) Service Port\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e12 to 24 VDC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBackplane Current\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e450 mA @ 5 VDC (Typical)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eResponse Time\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.5 ms maximum (ON\/OFF)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 to 60 °C (32 to 140 °F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eEngineering Advantages\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMassive Network Scalability:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIC693DNM200\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ehandles up to 63 slaves and nearly 4KB of input\/output data. This allows for the integration of large-scale distributed I\/O systems and smart sensors without saturating the PLC's main backplane bandwidth.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMulti-Protocol I\/O Support:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module supports Poll, Strobe, Cyclic, and Change-of-State (COS) I\/O connections. This flexibility ensures compatibility with a vast range of third-party DeviceNet devices, allowing for optimized network traffic based on specific process requirements.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDeterministic Performance:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eA maximum response time of 0.5 milliseconds ensures high-speed discrete control. This low-latency processing prevents timing jitter in synchronized applications like material handling and automated assembly lines.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eBuilt-in Service Interface:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe dedicated service port simplifies network commissioning and maintenance. Engineers can monitor bus health and configure slave parameters directly through the module without interrupting the main PLC communication cycle.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRobust Electrical Protection:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDesigned for harsh factory floors, the module withstands inrush currents up to 5.4 Amps and operates within a wide storage temperature range of -40 to 85 °C, protecting the hardware during transport and downtime in extreme climates.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFAQs\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIn which slots can I install the IC693DNM200?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYou can install this module in any available slot of a Series 90-30 or RX3i rack, except for slots 0 and 1, which are reserved for the Power Supply and CPU respectively.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this module require an external power supply?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The DeviceNet network itself requires a 12 to 24 VDC power supply to power the bus and transceiver circuits. The module draws its internal logic power (450mA) directly from the PLC backplane.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan the IC693DNM200 work with PACSystems RX3i?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIC693DNM200\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003emaintains full compatibility with the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePACSystems RX3i\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003euniversal backplane, making it an ideal choice for legacy migrations or modernizing Series 90-30 systems to the RX3i platform.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":44075650056291,"sku":"IC693DNM200","price":175.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/406._7ccf4c28-d4e0-45ae-8043-f28b209f11b6.jpg?v=1774336724","url":"https:\/\/www.autocontrolglobal.com\/products\/63-slave-devicenet-master-ge-fanuc-90-30-ic693dnm200","provider":"AutoControl Global","version":"1.0","type":"link"}