{"product_id":"6gk1143-0tb01-siemens-simatic-net-ethernet-processors","title":"6GK1143-0TB01 Siemens SIMATIC NET Ethernet Processors","description":"\u003ch2\u003eSiemens 6GK1143-0TB01 SIMATIC NET CP 1430 TF Communication Processor\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eSiemens 6GK1143-0TB01\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eCP 1430 TF\u003c\/strong\u003e Communication Processor, operates as a dedicated hardware component for deterministic data exchange and time synchronization within SIMATIC S7-300 Industrial Ethernet networks.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable style=\"width: 100%; height: 391.875px;\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003cth style=\"width: 31.9109%; height: 19.5938px;\"\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth style=\"width: 63.3553%; height: 19.5938px;\"\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 31.9109%; height: 19.5938px;\"\u003eModel\u003c\/td\u003e\n\u003ctd style=\"width: 63.3553%; height: 19.5938px;\"\u003eCP 1430 TF (6GK1143-0TB01)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 31.9109%; height: 19.5938px;\"\u003eBrand\u003c\/td\u003e\n\u003ctd style=\"width: 63.3553%; height: 19.5938px;\"\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 31.9109%; height: 19.5938px;\"\u003eOrigin\u003c\/td\u003e\n\u003ctd style=\"width: 63.3553%; height: 19.5938px;\"\u003eGermany\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 31.9109%; height: 39.1875px;\"\u003eWeight\u003c\/td\u003e\n\u003ctd style=\"width: 63.3553%; height: 39.1875px;\"\u003eStandard S7-300 module weight (0.60 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 31.9109%; height: 19.5938px;\"\u003eDimensions\u003c\/td\u003e\n\u003ctd style=\"width: 63.3553%; height: 19.5938px;\"\u003eStandard S7-300 single-slot width\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 31.9109%; height: 19.5938px;\"\u003eOperating Temp\u003c\/td\u003e\n\u003ctd style=\"width: 63.3553%; height: 19.5938px;\"\u003e0 to +60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 31.9109%; height: 39.1875px;\"\u003ePower Consumption\u003c\/td\u003e\n\u003ctd style=\"width: 63.3553%; height: 39.1875px;\"\u003eBackplane bus supplied\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 31.9109%; height: 19.5938px;\"\u003eProduct Line\u003c\/td\u003e\n\u003ctd style=\"width: 63.3553%; height: 19.5938px;\"\u003eSIMATIC NET\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 31.9109%; height: 39.1875px;\"\u003eController Compatibility\u003c\/td\u003e\n\u003ctd style=\"width: 63.3553%; height: 39.1875px;\"\u003eSIMATIC S7-300\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 31.9109%; height: 39.1875px;\"\u003eNetwork Interface\u003c\/td\u003e\n\u003ctd style=\"width: 63.3553%; height: 39.1875px;\"\u003eIndustrial Ethernet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 31.9109%; height: 19.5938px;\"\u003eTiming Accuracy\u003c\/td\u003e\n\u003ctd style=\"width: 63.3553%; height: 19.5938px;\"\u003e1 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 58.7812px;\"\u003e\n\u003ctd style=\"width: 31.9109%; height: 58.7812px;\"\u003eProtocol Support\u003c\/td\u003e\n\u003ctd style=\"width: 63.3553%; height: 58.7812px;\"\u003eS7 communication, PG\/OP communication, Time synchronization\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 31.9109%; height: 19.5938px;\"\u003eMounting\u003c\/td\u003e\n\u003ctd style=\"width: 63.3553%; height: 19.5938px;\"\u003eS7-300 DIN Rail \/ Backplane rack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eDeterministic Industrial Ethernet and Backplane Execution\u003c\/h3\u003e\n\u003cp\u003eThe CP 1430 TF module handles communication processing directly via onboard dedicated hardware, bypassing CPU scan cycle latency. By leveraging specialized internal firmware flash execution, the module offloads Industrial Ethernet network tasks from the host S7-300 controller. The backplane bus communication velocity allows deterministic 1 ms time synchronization updates across distributed nodes. This hardware architecture ensures predictable I\/O data throughput, cross-station event tagging, and deterministic data exchange without interrupting cyclic PLC program execution.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the CP 1430 TF require CPU processing resources for time synchronization?\u003c\/p\u003e\n\u003cp\u003eA: No, the module processes time synchronization and network protocol tasks using dedicated internal hardware, functioning independently of the host S7-300 CPU scan cycle.\u003c\/p\u003e\n\u003cp\u003eQ: How is the module mounted and powered within the controller architecture?\u003c\/p\u003e\n\u003cp\u003eA: The module installs directly onto a standard S7-300 DIN rail rack slot and draws operating power directly from the backplane bus.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eEnsure complete power removal from the S7-300 backplane rack before inserting or removing the CP 1430 TF module. Mount the unit securely onto the DIN rail using the module retention screw to maintain reliable backplane connector pin alignment. Route Industrial Ethernet cables through dedicated conduit, keeping signal lines isolated from high-voltage motor wires to mitigate electromagnetic interference. Connect the shield of the network cable directly to a low-impedance functional earth (FE) ground point. Verify a minimum of 5 thread engagement turns on all terminal strain-relief fittings.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":43926014689379,"sku":"6GK1143-0TB01","price":400.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/227.2_26ac1925-43e4-4a77-bf5f-532971512515.jpg?v=1767057899","url":"https:\/\/www.autocontrolglobal.com\/products\/6gk1143-0tb01-siemens-simatic-net-ethernet-processors","provider":"AutoControl Global","version":"1.0","type":"link"}