6SE7021-8TB61 Siemens MASTERDRIVES VC Inverter
6SE7021-8TB61 Siemens MASTERDRIVES VC Inverter
6SE7021-8TB61 Siemens MASTERDRIVES VC Inverter
/ 3

6SE7021-8TB61 Siemens MASTERDRIVES VC Inverter

  • Manufacturer: Siemens

  • Part Number: 6SE7021-8TB61

  • Condition:New with Original Package

  • Product Type: Frequency Converters

  • Country of Origin: USA

  • Payment:T/T, Western Union

  • Shipping port: Xiamen

  • Warranty: 12 months

Siemens 6SE7021-8TB61 SIMOVERT MASTERDRIVES VC Frequency Converter

Configured for precision speed and torque regulation in complex industrial setups, the Siemens 6SE7021-8TB61 (6SE7021-8TB61 Frequency Converter) provides direct physical/electrical execution.

Hardware Specifications

Parameter Specification
Model 6SE7021-8TB61
Brand Siemens
Origin Standard Industrial Manufacturing
Weight Not specified
Dimensions Standard cabinet-mount profile
Operating Temp 0 deg C to +40 deg C (Up to +50 deg C with derating)
Power Consumption 11 kW (15 HP) rated power
Current Rating 25 Amps (Nominal)
Input Voltage 3-Phase AC, 380 V to 480 V (+/- 10%)
Output Frequency 0 Hz to 650 Hz
Control Method Field-Oriented Vector Control

Backplane Bus Communication Velocity and Deterministic Networks

Engineered to operate within demanding factory environments, the drive architecture utilizes high-speed backplane bus communication velocity and deterministic networking protocols to manage multi-axis synchronization. The internal control processor executes rapid firmware loops, ensuring low-latency feedback handling for vector control loops. Furthermore, the drive supports firmware flash compatibility and scalable I/O integration via optional technology boards, maintaining tight coordination across complex motion control topologies without communication bottlenecks.

Frequently Asked Questions

Q: Can this frequency converter be replaced directly with a newer SINAMICS drive without software changes?

A: No. A migration to SINAMICS platforms requires physical hardware modifications and adjustments to the communication mapping within the PLC program.

Q: What actions should be taken if the drive triggers an overtemperature fault code?

A: Maintenance personnel must inspect the internal forced-air cooling fans for unrestricted rotation and check that cabinet ventilation filters remain clean and free of dust blockages.

Field Installation Guidelines

  1. Disconnect and lock out all 3-phase AC input power sources and connected motor leads before handling the drive.
  2. Mount the converter securely to the vertical backplate of the electrical cabinet, ensuring proper clearance above and below for the internal forced-air cooling profile.
  3. Terminate the 380-480 V AC supply cables, motor feeder wires, and control signal lines while applying proper shielding and grounding practices to minimize electromagnetic interference.
  4. Verify all wiring integrity, input voltage levels, and terminal torque settings before energizing the cabinet and uploading parameter configurations.
You may also like