{"product_id":"6se7021-8tb61-siemens-masterdrives-vc-inverter","title":"6SE7021-8TB61 Siemens MASTERDRIVES VC Inverter","description":"\u003ch2\u003eSiemens 6SE7021-8TB61 SIMOVERT MASTERDRIVES VC Frequency Converter\u003c\/h2\u003e\n\u003cp\u003eConfigured for precision speed and torque regulation in complex industrial setups, the \u003cstrong\u003eSiemens 6SE7021-8TB61\u003c\/strong\u003e (\u003cstrong\u003e6SE7021-8TB61\u003c\/strong\u003e Frequency Converter) provides direct physical\/electrical execution.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e6SE7021-8TB61\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eStandard Industrial Manufacturing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eNot specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard cabinet-mount profile\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 deg C to +40 deg C (Up to +50 deg C with derating)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e11 kW (15 HP) rated power\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Rating\u003c\/td\u003e\n\u003ctd\u003e25 Amps (Nominal)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e3-Phase AC, 380 V to 480 V (+\/- 10%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Frequency\u003c\/td\u003e\n\u003ctd\u003e0 Hz to 650 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl Method\u003c\/td\u003e\n\u003ctd\u003eField-Oriented Vector Control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Bus Communication Velocity and Deterministic Networks\u003c\/h3\u003e\n\u003cp\u003eEngineered to operate within demanding factory environments, the drive architecture utilizes high-speed backplane bus communication velocity and deterministic networking protocols to manage multi-axis synchronization. The internal control processor executes rapid firmware loops, ensuring low-latency feedback handling for vector control loops. Furthermore, the drive supports firmware flash compatibility and scalable I\/O integration via optional technology boards, maintaining tight coordination across complex motion control topologies without communication bottlenecks.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Can this frequency converter be replaced directly with a newer SINAMICS drive without software changes?\u003c\/p\u003e\n\u003cp\u003eA: No. A migration to SINAMICS platforms requires physical hardware modifications and adjustments to the communication mapping within the PLC program.\u003c\/p\u003e\n\u003cp\u003eQ: What actions should be taken if the drive triggers an overtemperature fault code?\u003c\/p\u003e\n\u003cp\u003eA: Maintenance personnel must inspect the internal forced-air cooling fans for unrestricted rotation and check that cabinet ventilation filters remain clean and free of dust blockages.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eDisconnect and lock out all 3-phase AC input power sources and connected motor leads before handling the drive.\u003c\/li\u003e\n\u003cli\u003eMount the converter securely to the vertical backplate of the electrical cabinet, ensuring proper clearance above and below for the internal forced-air cooling profile.\u003c\/li\u003e\n\u003cli\u003eTerminate the 380-480 V AC supply cables, motor feeder wires, and control signal lines while applying proper shielding and grounding practices to minimize electromagnetic interference.\u003c\/li\u003e\n\u003cli\u003eVerify all wiring integrity, input voltage levels, and terminal torque settings before energizing the cabinet and uploading parameter configurations.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":43915270258787,"sku":"6SE7021-8TB61","price":400.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/187_7c9c37bd-7bc0-439d-bd0c-ae8b08ff4e83.jpg?v=1766631898","url":"https:\/\/www.autocontrolglobal.com\/products\/6se7021-8tb61-siemens-masterdrives-vc-inverter","provider":"AutoControl Global","version":"1.0","type":"link"}