{"product_id":"8-channel-isolated-analog-input-module-ge-ic200alg240-eb","title":"8 Channel Isolated Analog Input Module | GE IC200ALG240-EB","description":"\u003ch2\u003eGE Fanuc IC200ALG240-EB VersaMax Analog Input Module\u003c\/h2\u003e\n\u003cp\u003eConfigured for high-precision signal acquisition in VersaMax PLC platforms, the \u003cstrong\u003eGE Fanuc IC200ALG240-EB\u003c\/strong\u003e (\u003cstrong\u003eIC200ALG240\u003c\/strong\u003e Isolated Analog Input Module) provides direct physical\/electrical execution. Field engineers install this 8-channel analog card onto a standard VersaMax carrier terminal base where it digitizes bi-polar voltage and uni-polar current process signals into 16-bit binary representation. Individual channel-to-channel optical isolators eliminate potential ground loop currents across distributed field sensors while transferring primary data across internal backplane logic structures.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eSub-Model \/ Revision\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eHardware Revision Detail\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eChannel Isolation Status\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eResolution\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eIC200ALG240-EB\u003c\/td\u003e\n\u003ctd\u003eHardware revision EB (Enhanced stability components)\u003c\/td\u003e\n\u003ctd\u003e8 Channels (Individually Isolated)\u003c\/td\u003e\n\u003ctd\u003e16-Bit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIC200ALG240 (Base)\u003c\/td\u003e\n\u003ctd\u003eBase VersaMax isolated analog input hardware architecture\u003c\/td\u003e\n\u003ctd\u003e8 Channels (Individually Isolated)\u003c\/td\u003e\n\u003ctd\u003e16-Bit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIC200ALG240-EB \/ IC200ALG240\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE Fanuc (Emerson)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.20 kg (2.0 kg shipping weight)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e110 x 66.8 x 50 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e100 mA maximum from 5 VDC backplane\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Channels\u003c\/td\u003e\n\u003ctd\u003e8 channels (Channel-to-channel and channel-to-system isolated)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Ranges (Voltage)\u003c\/td\u003e\n\u003ctd\u003e+\/-10 VDC, 0 to 10 VDC, +\/-5 VDC, 0 to 5 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Ranges (Current)\u003c\/td\u003e\n\u003ctd\u003e4-20 mA, 0-20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Impedance\u003c\/td\u003e\n\u003ctd\u003eVoltage mode: \u0026gt; 1 M-ohm; Current mode: 250 ohm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eA\/D Conversion\u003c\/td\u003e\n\u003ctd\u003e16-Bit resolution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e+\/-0.1% of full scale typical at 25 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExternal Power Supply\u003c\/td\u003e\n\u003ctd\u003e19.5 to 30 VDC (24 VDC nominal)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation Voltage\u003c\/td\u003e\n\u003ctd\u003e250 VAC continuous; 1500 VAC for 1 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Bus Communication Velocity and Signal Processing\u003c\/h3\u003e\n\u003cp\u003eThe 16-bit analog conversion circuitry updates all 8 isolated input channels every 5 ms, pushing refreshed register values across the VersaMax carrier backplane. Internal bus logic maintains backplane bus communication velocity during high channel density scaling across expanded sub-racks. Flash firmware compatibility within host VersaMax CPU modules ensures synchronized scan timing without introducing buffer delays over Profinet and EtherNet\/IP deterministic networks, enabling accurate PID loop execution across complex process control networks.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How do technical personnel configure voltage versus current modes on individual channels of the IC200ALG240-EB?\u003c\/p\u003e\n\u003cp\u003eA: Engineers configure each channel independently as a voltage or current input within the VersaMax PLC programming software, setting software parameters to match field sensor output specifications without needing hardware jumper changes.\u003c\/p\u003e\n\u003cp\u003eQ: Can the IC200ALG240-EB module be hot-swapped while the VersaMax rack is energized?\u003c\/p\u003e\n\u003cp\u003eA: Technical staff must disconnect primary backplane logic power and remove external 24 VDC field power prior to extracting or inserting the module to prevent electrical damage and backplane communications faults.\u003c\/p\u003e\n\u003cp\u003eQ: What mechanisms detect broken wire conditions on 4-20 mA current loops?\u003c\/p\u003e\n\u003cp\u003eA: Built-in diagnostic software monitors signal levels on 4-20 mA configured channels; if loop current falls below the low-threshold limit, the module sets an open-wire alarm flag and illuminates the front-panel fault LED indicator.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eFollow these sequential steps during cabinet mounting and analog signal wiring:\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003eDe-energize primary rack power and isolate external 24 VDC loop power supplies before installing hardware onto the rail.\u003c\/li\u003e\n\u003cli\u003eAlign the module edge connector with the VersaMax carrier base slot and press downward until side mounting latches snap locked.\u003c\/li\u003e\n\u003cli\u003eConnect 4-20 mA or voltage sensor wires to the removable terminal block, observing correct polarity for positive and negative signal terminals.\u003c\/li\u003e\n\u003cli\u003eRoute twisted-pair shielded analog signal cables in dedicated wire raceways separated from high-voltage AC power and motor drive cables.\u003c\/li\u003e\n\u003cli\u003eTerminate signal cable shields to the cabinet ground bar using short copper grounding straps, then reapply power to inspect the module health LED.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":43968053379171,"sku":"IC200ALG240-EB","price":400.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/33_ad10039d-5992-4091-994b-49593f7ef340.jpg?v=1769411243","url":"https:\/\/www.autocontrolglobal.com\/products\/8-channel-isolated-analog-input-module-ge-ic200alg240-eb","provider":"AutoControl Global","version":"1.0","type":"link"}