{"product_id":"8270-1013-woodward-overspeed-protection-module","title":"8270-1013 Woodward Overspeed Protection Module","description":"\u003ch2\u003eWoodward 8270-1013 ProTech-GII Overspeed Protection Module\u003c\/h2\u003e\n\u003cp\u003eConfigured for high-speed deterministic speed monitoring in industrial prime mover control platforms, the \u003cstrong\u003eWoodward 8270-1013\u003c\/strong\u003e (\u003cstrong\u003e8270-1013\u003c\/strong\u003e ProTech-GII Overspeed Protection Module) provides direct physical\/electrical execution. The device evaluates shaft rotation frequency using dedicated magnetic speed sensors and energizes high-speed trip outputs upon detecting threshold violations. Its bulkhead-mount design isolates the speed sensing circuitry from external mechanical stress, delivering dedicated emergency shutdown execution independent of the primary governor loop.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e8270-1013\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eWoodward\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e330 mm x 486 mm x 153 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-40 to +85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e24 VDC nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eProTech-GII Overspeed Protection Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eArchitecture\u003c\/td\u003e\n\u003ctd\u003eTriple Modular Redundancy (TMR) 2oo3 voting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensor Inputs\u003c\/td\u003e\n\u003ctd\u003eActive or passive magnetic pickup (MPU)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Contacts\u003c\/td\u003e\n\u003ctd\u003eHigh-speed relay trip contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIngress Protection\u003c\/td\u003e\n\u003ctd\u003eIP56 rated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e5-95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eActuator Loop and Speed Sensing Dynamics\u003c\/h3\u003e\n\u003cp\u003eThe unit incorporates specialized signal processing channels designed to interface directly with active or passive magnetic pickup (MPU) sensors. Speed processing electronics continuously monitor input pulse train frequencies, executing high-speed actuator loop feedback response routines to isolate overspeed transients before mechanical damage occurs. Furthermore, internal watchdog circuits monitor system processing states while integrated heat sink dissipation pathways maintain component temperatures within nominal limits across the industrial operating envelope.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What relay reaction latency occurs during an overspeed condition?\u003c\/p\u003e\n\u003cp\u003eA: Internal triple modular redundancy (TMR) voting logic processes sensor pulse changes continuously, driving the high-speed output relays to change state within milliseconds of crossing the programmed overspeed limit.\u003c\/p\u003e\n\u003cp\u003eQ: How does the module handle a single magnetic pickup sensor failure?\u003c\/p\u003e\n\u003cp\u003eA: The system utilizes a 2oo3 voting architecture across three independent internal hardware channels. A single sensor loss or signal disruption generates a fault alarm while the remaining two functional channels continue executing accurate speed evaluation without triggering a false trip.\u003c\/p\u003e\n\u003cp\u003eQ: What physical precautions apply to bulkhead mounting in high-vibration zones?\u003c\/p\u003e\n\u003cp\u003eA: Installation technicians must secure the unit directly to a rigid, unyielding panel frame using four M8 fasteners torqued to specified limits. Vibration isolation dampers must be placed behind the mounting feet if mechanical resonance exceeds IP56 structural limits.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eMount the chassis vertically against a stable bulkhead surface to optimize thermal convection across the rear cooling surface. Maintain a minimum 100 mm clearance around all sides to ensure unhindered airflow. Route all magnetic pickup (MPU) signal cables through dedicated grounded metallic conduit separate from high-voltage AC lines or inductive drive output wiring.\u003c\/p\u003e\n\u003cp\u003eFirmly connect the main protective earth (PE) ground stud directly to the central panel ground bus bar using a short, stranded copper conductor (minimum 4 mm sq). Strip sensor and relay wiring to specified terminal insertion lengths, securing screw terminals to avoid loose contact resistance. Always verify power supply polarity and maintain the incoming 24 VDC voltage within nominal limits before powering on the module.\u003c\/p\u003e","brand":"Woodward","offers":[{"title":"Default Title","offer_id":43906615509091,"sku":"8270-1013","price":310.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/44_c4e22841-c864-4ab2-b620-5e00856fbc0e.jpg?v=1766460938","url":"https:\/\/www.autocontrolglobal.com\/products\/8270-1013-woodward-overspeed-protection-module","provider":"AutoControl Global","version":"1.0","type":"link"}