8810-HI-TX GE Safety Analog Input Module 4-20 mA HART
8810-HI-TX GE Safety Analog Input Module 4-20 mA HART
8810-HI-TX GE Safety Analog Input Module 4-20 mA HART
/ 3

8810-HI-TX GE Safety Analog Input Module 4-20 mA HART

  • Manufacturer: GE Fanuc

  • Part Number: 8810-HI-TX

  • Condition:New with Original Package

  • Product Type: Analog Input Modules

  • Country of Origin: USA

  • Payment:T/T, Western Union

  • Shipping port: Xiamen

  • Warranty: 12 months

GE 8810-HI-TX Safety Analog Input Module

The GE 8810-HI-TX, also cataloged as the 8810-HI-TX Safety Analog Input Module, operates as a dedicated hardware component for 4-20 mA loop signal acquisition and HART status pass-through within safety instrumented systems.

Hardware Specifications

Parameter Specification
Model 8810-HI-TX
Brand GE
Origin USA
Weight Standard Safety I/O Module Weight
Dimensions Standard DIN-Rail Mounting Enclosure
Operating Temp -40 deg C to +70 deg C
Power Consumption 70 mA (system), 350 mA (field at 24 VDC)
Input Channels 8 isolated analog channels (2-, 3-, or 4-wire)
Signal Range 4-20 mA nominal (0.25-24 mA full span)
Resolution 16-bit
Accuracy +/-0.1% of span at 25 deg C
Update Speed 25 ms per channel (0.75 s per point HART)
Fault Detection Short circuit (23.5 mA), open circuit (<0.5 mA)
Safety Rating SIL 2 compliant
Hazardous Location Class I, Division 2 certified

Backplane Bus Communication & Firmware Flash Compatibility

The analog input module executes high-frequency A/D sampling over a 16-bit resolution core, transferring IEEE754 floating-point process variables across deterministic backplane bus communication channels. Internal firmware logic scans each channel every 25 ms, isolating parameter changes while maintaining firmware flash compatibility with upstream safety controllers. Integrated line fault detection circuits continuously evaluate loop impedance, reporting open-circuit and short-circuit threshold breaches directly to system diagnostic registers without interrupting background HART communication acquisition.

Frequently Asked Questions

Q: How does the 8810-HI-TX handle line fault detection during sensor open-circuit conditions?

A: The module logic detects loop current dropping below 0.5 mA, triggering an open-circuit diagnostic state and setting channel fault flags across the internal backplane bus.

Q: What external supply voltage is required to power connected field transmitters?

A: Connected 2-, 3-, or 4-wire loop transmitters draw field power from a regulated 24 VDC supply rail (such as an 8914-PSAC unit), delivering at least 10.2 V at 20 mA to maintain transmitter compliance voltage.

Field Installation Guidelines

Mount the module on an grounded DIN-rail assembly inside a suitable NEMA or IP-rated enclosure approved for Class I, Division 2 environments. Route 4-20 mA signal wires using twisted-pair shielded cabling, ensuring physical separation from high-voltage AC conductors to prevent electromagnetic interference. Terminate cable shields at a single point on the main enclosure ground bar, verify that terminal connection torque matches mechanical specifications, and confirm 24 VDC field power polarity before energizing the system.