900B01-0301 Honeywell Baseplate 900TEK-0200 Terminal Block Kit
900B01-0301 Honeywell Baseplate 900TEK-0200 Terminal Block Kit
900B01-0301 Honeywell Baseplate 900TEK-0200 Terminal Block Kit
/ 3

900B01-0301 Honeywell Baseplate 900TEK-0200 Terminal Block Kit

  • Manufacturer: HONEYWELL

  • Part Number: 900B01-0301 + 900TEK-0200

  • Condition:New with Original Package

  • Product Type: Automation Baseplate Racks

  • Country of Origin: Sweden

  • Payment:T/T, Western Union

  • Shipping port: Xiamen

  • Warranty: 12 months

Honeywell 900B01-0301 HC900 Rack and Terminal Kit

The Honeywell 900B01-0301 + 900TEK-0200, also cataloged as the 900B01-0301 Baseplate and Terminal Kit, operates as a dedicated hardware component for structural module retention and electrical bus interfacing within HC900 Hybrid Controller networks. The assembly establishes parallel backplane trace connections to bridge data frames between the central processing units, power supply units, and active I/O modules. The primary chassis structure paths logic signals directly through localized gold-plated bus connectors while concurrently routing external sensor wiring through the integrated compression clamping nodes.

Hardware Specifications

Parameter Specification
Model 900B01-0301 + 900TEK-0200
Brand Honeywell
Origin USA
Weight 2.0 kg combined (Baseplate: 1.2 kg, Terminal Kit: 0.8 kg)
Dimensions Baseplate: 300 x 200 x 50 mm, Terminal Kit: 250 x 150 x 40 mm
Operating Temp 0 to +60 deg C
Power Consumption Passive backplane bus distribution (Supports up to 5V at 40 mA / 24V at 200 mA module loads)
System Compatibility Honeywell HC900 Hybrid Controller
Modules Supported CPU, Power Supply, and up to 12 I/O modules with temperature derating
Field Capacity Up to 200 I/O points across terminal blocks
Terminal Block Type Compression-type terminal blocks
Mounting Options DIN-rail or direct panel mounting
Isolation Rating 500 VDC channel-to-channel; 600 VDC logic isolation
Storage Temperature -40 to +85 deg C
Humidity Range 5 percent to 95 percent non-condensing
Certifications CE, UL, CSA

Process Control & DCS Instrumentation

The baseplate assembly integrates a multi-layer backplane network featuring dedicated hardware traces designed to maintain 500 VDC channel-to-channel isolation and 600 VDC logic isolation across all slotted connections. The framework accommodates 4-20 mA HART loop protocol modules and analog output channels without inducing signal impedance mismatches on the passive bus lines. When routing high-density signals through the 900TEK-0200 terminal matrix, the internal solid-state termination rails minimize signal attenuation, sustaining a 12-bit D/A resolution and 0.1 percent full-scale accuracy parameters across the physical bus interface during concurrent channel updates.

Frequently Asked Questions

Q: Does the 900B01-0301 backplane require manual address jumper configuration when installing redundant CPUs?

A: No. The HC900 backplane architecture uses hardwired slot identification pinouts embedded inside the chassis assembly. The system identifies module types, including redundant CPUs or power supplies, automatically based on physical slot allocation rather than manual jumpers.

Q: What physical limitations dictate the module capacity expansion from 10 channels up to 12 channels?

A: The baseplate layout structurally permits 12 modules, but thermal accumulation varies depending on cabinet airflow. When operating at the upper +60 deg C threshold, you must enforce ambient temperature derating limits and limit high-current analog outputs to prevent localized heat pockets.

Q: Can the 900TEK-0200 compression terminals accept solid and stranded wires simultaneously within a single clamp cage?

A: No. Inserting mismatched wire topologies into a single compression cage degrades physical contact friction, leading to intermittent loop termination faults or high contact resistance that skews the 0.1 percent analog calibration accuracy.

Field Installation Guidelines

Mount the 900B01-0301 chassis vertically onto a flat, grounded industrial enclosure panel using M5 steel screws, or lock the rear integral brackets firmly onto standard symmetric DIN rails. Ensure the mounting orientation permits unrestricted vertical airflow past the backplane structure to maintain operational temperatures below +60 deg C.

Electrostatic discharge breaks down internal circuit paths. Field personnel must wear a grounded ESD wrist strap before handling the exposed backplane connectors or inserting active modules into the chassis slots.

Fasten the 900TEK-0200 terminal block kit directly adjacent to the baseplate assembly, verifying that the heavy-duty ribbon cables align straight without twisting or bending beyond a 30 mm radius. Route all 4-20 mA instrumentation loops through distinct metal conduit lanes separated from AC motor leads to prevent electromagnetic fields from coupling onto the passive analog measurement paths.

You may also like