{"product_id":"990-08-xx-03-00-bently-nevada-2-wire-velocity-transducer","title":"990-08-xx-03-00 Bently Nevada 2-Wire Velocity Transducer","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 990-08-xx-03-00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efunctions as a high-performance, 2-wire velocity vibration transmitter designed for absolute casing vibration measurement. This sensor integrates the transducer and signal conditioning electronics into a single stainless-steel housing. It converts mechanical casing motion into a proportional electrical signal compatible with Bently Nevada 3300 and 3500 Machinery Protection Systems. By mounting directly to the machine housing, it provides critical data for detecting structural imbalances, bearing wear, and misalignment. We deliver this unit as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New and Original\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ein factory packaging.\u003c\/p\u003e\n\u003ch3\u003ePart Number Breakdown: 990-08-xx-03-00\u003c\/h3\u003e\n\u003cp\u003eThe 990-08 series uses a modular part numbering system to tailor the sensor to specific machinery requirements.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eOption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e08\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eTransmitter Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVelocity Transducer (Casing Measurement)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003exx\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSensitivity\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDefines output (e.g., 25, 50, or 100 mV\/in\/sec)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e03\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMounting Thread\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eStandard 3\/8-24 UNF Stud Mount\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e00\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAgency Approval\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eStandard hazardous area certifications (ATEX\/IECEx\/CSA)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMeasurement Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCasing Vibration (Velocity)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eFrequency Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e10 Hz to 1,000 Hz (600 to 60,000 CPM)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSensitivity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDependent on \"xx\" option (e.g., 50 mV\/in\/sec)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDynamic Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e±50 g peak\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOutput Signal\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVoltage proportional to velocity\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eHousing Material\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e316L Stainless Steel\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-30°C to +100°C (-22°F to +212°F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eConnection\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2-wire system\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDirect Casing Integration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 990-08 mounts directly to the bearing housing or machine casing. This allows the sensor to capture structural vibration data that proximity probes (measuring relative shaft motion) might miss, providing a complete machinery health profile.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSimplified 2-Wire Loop:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 2-wire design reduces field wiring complexity. It utilizes the same wires for power and signal transmission, lowering installation costs and minimizing potential failure points in the wiring loop.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRuggedized for Extreme Environments:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 316L stainless steel housing resists corrosive chemicals and salt spray. With an operating temperature rating up to 100°C and hermetic sealing, this transmitter thrives in offshore platforms and steam turbine halls.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eBroad Frequency Coverage:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 10 Hz to 1,000 Hz range captures the fundamental frequencies of most industrial rotating equipment. This ensures early detection of common faults such as unbalance, vane pass frequencies, and mechanical looseness.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How do I select the correct \"xx\" sensitivity for my application?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe \"xx\" value determines the signal scale (e.g., 50 mV\/in\/sec). You must match this to the configuration of your 3500\/42M or 3300\/16 monitor module. Using the wrong sensitivity will result in incorrect vibration readings and potential false trips.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does the 990-08 require a separate Proximitor®?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eNo. Unlike proximity probes, the 990-08 is a self-contained transmitter. It does not require an external signal conditioner; it connects directly to the monitor I\/O or a 24V DC power loop.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can this sensor be used in hazardous gas environments?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eYes. The 990-08-xx-03-00 carries multiple global certifications including ATEX, IECEx, and CSA. When installed with an approved intrinsic safety barrier, it is safe for use in Zone 0, 1, or 2 (Class I, Div 1 or 2).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the benefit of the 3\/8-24 UNF mounting thread?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThis thread size provides a high-stiffness mechanical bond to the machine. Proper torquing of the 3\/8-24 stud ensures the sensor accurately tracks high-frequency casing vibrations without introducing mounting resonance errors.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":44177258545251,"sku":"990-08-xx-03-00","price":188.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/376.1_4f2626e3-4062-47b0-bfe5-49d0855c0f1b.jpg?v=1778655989","url":"https:\/\/www.autocontrolglobal.com\/products\/990-08-xx-03-00-bently-nevada-2-wire-velocity-transducer","provider":"AutoControl Global","version":"1.0","type":"link"}