{"product_id":"aai141-s00-k4a00-yokogawa-centum-vp-analog-input-module","title":"AAI141-S00\/K4A00 Yokogawa CENTUM VP Analog Input Module","description":"\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eYokogawa AAI141-S00\/K4A00 Analog Input Module\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eYokogawa AAI141-S00\/K4A00\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eAAI141\u003c\/strong\u003e Analog Input Module, operates as a dedicated hardware component for 16-channel non-isolated 4-20 mA DC signal acquisition within Yokogawa CENTUM VP and FIO networks.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eCode\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eType\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAAI141\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBase Model\u003c\/td\u003e\n\u003ctd\u003eAnalog Input Module (4 to 20 mA, 16-channel, Non-Isolated)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e-S\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eType Code\u003c\/td\u003e\n\u003ctd\u003eStandard Type\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e0\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHardware Option\u003c\/td\u003e\n\u003ctd\u003eBasic Type (No explosion protection)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e0\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEnvironmental Option\u003c\/td\u003e\n\u003ctd\u003eBasic Type\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\/K4A00\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOption Code\u003c\/td\u003e\n\u003ctd\u003eWith KS Cable Interface Adapter (Model: ATK4A-00)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eAAI141-S00\/K4A00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eStandard Manufacturer Sourcing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard Yokogawa FIO Module Dimensions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e310 mA at 5 VDC, 450 mA at 24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Channels\u003c\/td\u003e\n\u003ctd\u003e16 channels, non-isolated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Signal\u003c\/td\u003e\n\u003ctd\u003e4 to 20 mA DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAllowable Input Current\u003c\/td\u003e\n\u003ctd\u003e27 mA max.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Resistance\u003c\/td\u003e\n\u003ctd\u003e400 ohm at 20 mA to 1 kohm at 4 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Resistance (Power OFF)\u003c\/td\u003e\n\u003ctd\u003e500 kohm or greater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Accuracy\u003c\/td\u003e\n\u003ctd\u003e+\/-16 uA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Update Period\u003c\/td\u003e\n\u003ctd\u003e10 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStep Response Time\u003c\/td\u003e\n\u003ctd\u003eApprox. 100 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Drift\u003c\/td\u003e\n\u003ctd\u003e+\/-16 uA per 10 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransmitter Power Supply\u003c\/td\u003e\n\u003ctd\u003e\u0026gt;= 14.8 VDC at 20 mA, \u0026lt;= 26.4 VDC at 0 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterface Adapter\u003c\/td\u003e\n\u003ctd\u003eATK4A-00 KS Cable Interface Adapter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProcess Control \u0026amp; DCS Instrumentation\u003c\/h3\u003e\n\u003cp\u003eThe module provides high-density signal acquisition for common-ground 4-20 mA loops, processing 16 analog channels into digital process values across a 10 ms update window. Internal power distribution circuits supply integrated loop power to 2-wire field transmitters with a guaranteed minimum terminal voltage of 14.8 VDC at 20 mA. Active current-limiting circuitry caps input overload conditions at 27 mA, while an unpowered input impedance exceeding 500 kohm maintains circuit integrity during node maintenance.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How does the non-isolated channel architecture affect loop wiring design on site?\u003c\/p\u003e\n\u003cp\u003eA: All 16 channels share a common internal signal ground. Consequently, connected 2-wire transmitters or external loop power sources must operate on a unified reference potential to avoid cross-channel ground loops.\u003c\/p\u003e\n\u003cp\u003eQ: What role does the \/K4A00 option code play in field connectivity?\u003c\/p\u003e\n\u003cp\u003eA: The \/K4A00 option mounts an ATK4A-00 adapter onto the front interface of the module. This allows a standard pre-fabricated multi-core KS cable to plug directly into the module and route signals to external terminal units, such as the AEA4D, eliminating point-to-point discrete cabinet wiring.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eAlign the module with the card guide rails of the designated FIO node chassis slot and slide it inward until the backplane bus header seats fully. Tighten the top and bottom panel retention screws to secure the physical assembly and verify cabinet frame grounding continuity.\u003c\/p\u003e\n\u003cp\u003eConnect the KS multi-core interface cable securely to the front ATK4A-00 adapter using the integrated latching fasteners. Route signal lines through low-voltage ducting, maintaining a minimum clearance of 200 mm from three-phase AC cabling. Connect incoming cable shields to the cabinet ground bar at a single point to prevent high-frequency noise from corrupting measurement accuracy.\u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":67662652506211,"sku":"AAI141-S00\/K4A00","price":360.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/894._095fe30b-a4cd-4ee4-9af7-d47cdd1c3b6f.jpg?v=1791423579","url":"https:\/\/www.autocontrolglobal.com\/products\/aai141-s00-k4a00-yokogawa-centum-vp-analog-input-module","provider":"AutoControl Global","version":"1.0","type":"link"}