{"product_id":"abb-3bse039293r1-ai880a-high-integrity-analog-i-o-new","title":"ABB 3BSE039293R1 AI880A High Integrity Analog I\/O New","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eABB AI880A (3BSE039293R1)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003erepresents the pinnacle of signal reliability within the S800 I\/O family. Designed specifically for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eHigh Integrity (HI)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eapplications, this module provides 8 channels of analog input with full\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eHART communication\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003epass-through. It functions as a critical component in Safety Instrumented Systems (SIS), facilitating the measurement of pressure, level, and flow in environments requiring SIL3 compliance. We offer this unit as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New and Original in Factory Packing\u003c\/strong\u003e, ensuring your safety loops meet the stringent requirements of modern process automation.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Details\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAI880A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3BSE039293R1\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eType\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHigh Integrity (HI) Analog Input\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eConfiguration\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSingle or Redundant (S\/R)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eChannels\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8 isolated HART channels\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSignal Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0..20 mA, 4..20 mA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eA\/D Resolution\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e12-bit\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCommunication\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHART Protocol (Version 5, 6, and 7)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Impedance\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e250 Ω (with TY801 shunt stick)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePower Dissipation\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2.4 W\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e–25°C to +70°C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSystem Compatibility\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eABB AC 800M High Integrity, Symphony Plus\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSafety Integrity Level (SIL) Readiness:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe AI880A supports High Integrity configurations. When paired with an AC 800M HI controller, it enables the deployment of SIL3 safety loops, providing the deterministic performance necessary for emergency shutdown (ESD) and fire and gas (F\u0026amp;G) systems.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRedundancy for Maximum Availability:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEngineers can configure the AI880A in redundant pairs. This ensures that a single module failure does not trip the safety system or cause process downtime, as the secondary module assumes the load instantly without signal interruption.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIntegrated HART Connectivity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module allows bidirectional communication with HART-enabled field devices. This enables remote calibration, asset management, and secondary variable monitoring directly through the 800xA system, reducing the need for manual field inspections.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eGalvanic Isolation and Noise Immunity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEvery channel features robust galvanic isolation. This architecture blocks common-mode noise and prevents electrical surges on one channel from affecting adjacent inputs or the central controller backplane.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFlexible Thermal Range:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBuilt for demanding industrial cabinets, the AI880A operates reliably from\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e–25°C up to +70°C\u003c\/strong\u003e. This eliminates the requirement for specialized cooling in many remote instrument enclosures (RIE).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the AI880A require a shunt stick for current measurements?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. For current input applications (4-20 mA), you must use the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eTY801 shunt stick\u003c\/strong\u003e. This provides the precise 250 Ω impedance required to convert the current signal into a voltage readable by the A\/D converter.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the difference between AI880 and AI880A?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe AI880A is the enhanced \"A\" version, offering improved diagnostics and broader support for newer HART device descriptors. It maintains complete backwards compatibility with existing AI880 termination units and software configurations.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan I use this module in a non-safety application?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWhile the AI880A is optimized for High Integrity and Safety loops, it functions perfectly in standard process control applications where high availability and redundant HART inputs are required.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I verify the \"High Integrity\" status during installation?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe module integrates natively with ABB's AC 800M HI controllers. During configuration in Control Builder M, the system identifies the AI880A's safety parameters and enforces the necessary constraints to maintain the SIL rating of the loop.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":44166460244067,"sku":"AI880A 3BSE039293R1","price":540.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/473._1247ec5d-2bd3-4b89-8e45-80b5621d6cb7.jpg?v=1778125708","url":"https:\/\/www.autocontrolglobal.com\/products\/abb-3bse039293r1-ai880a-high-integrity-analog-i-o-new","provider":"AutoControl Global","version":"1.0","type":"link"}