{"product_id":"abb-ai830-s800-i-o-analog-input-module-3bse008519r1-resistance-measurement","title":"ABB AI830 S800 I\/O Analog Input Module 3BSE008519R1 Resistance Measurement","description":"\u003ch2\u003eABB AI830 Analog Input Module\u003c\/h2\u003e\n\u003cp\u003eConfigured for high-precision sensor data acquisition in ABB S800 I\/O and AC 800M control systems, the \u003cstrong\u003eABB AI830\u003c\/strong\u003e (\u003cstrong\u003e3BSE008519R1\u003c\/strong\u003e) Analog Input Module provides direct electrical interface for field-based instrumentation. This module serves as an primary I\/O component designed to monitor resistive temperature detectors and analog voltage\/resistance inputs, enabling real-time signal conversion for industrial process logic.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eAI830\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eSweden\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e5.1 cm x 12.7 cm x 12.7 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-20 deg C to +55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e~ 3 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Channels\u003c\/td\u003e\n\u003ctd\u003e8 channels (Pt100, Ni100\/120, Cu10, R)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003e50 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e12 bits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProfinet \/ EtherNet\/IP deterministic networks\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eABB AI830\u003c\/strong\u003e module maintains integration within the S800 I\/O architecture by supporting deterministic data bus communication. It operates in tandem with compatible Module Termination Units (TU810, TU812, TU814, TU830) to ensure signal integrity across the backplane. The module firmware provides consistent sampling intervals, ensuring that thermocouple and resistance-based measurements are processed with minimal latency. Through its I\/O density scaling capabilities, the AI830 facilitates efficient data throughput, allowing the controller to maintain synchronous execution loops across diverse industrial network environments.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Can the AI830 be replaced while the control system remains energized?\u003c\/p\u003e\n\u003cp\u003eA: Yes, the AI830 supports hot-swap operations. The design allows for module removal and installation while the system is under power, provided that standard electrical safety precautions are followed and the associated process loop is safely parked.\u003c\/p\u003e\n\u003cp\u003eQ: Which Module Termination Units (MTU) are compatible with this device?\u003c\/p\u003e\n\u003cp\u003eA: The AI830 requires the use of specific MTUs to ensure correct signal routing. Compatible units include the TU810, TU812, TU814, and TU830, which provide the necessary physical connection points and field-wiring terminations.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eMount the module on a standard DIN rail within the I\/O cabinet. Prior to installation, inspect the MTU contact pins to ensure they are free of debris or oxidation. Connect the field wiring to the chosen MTU, ensuring that all cable shields are properly terminated at the system ground bar to suppress electromagnetic interference. Once the module is seated into the MTU, verify the 24 VDC power supply connection and monitor the status LEDs for correct initialization. Ensure that the total loop resistance for connected sensors remains within the specified operating range to prevent measurement errors.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":44301893795939,"sku":"AI830 3BSE008519R1","price":284.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/155._06ada080-6ca2-425e-80be-8e5b3233303b.jpg?v=1782726719","url":"https:\/\/www.autocontrolglobal.com\/products\/abb-ai830-s800-i-o-analog-input-module-3bse008519r1-resistance-measurement","provider":"AutoControl Global","version":"1.0","type":"link"}