{"product_id":"abb-bailey-imfbs01-field-bus-slave-module-infi-90-dcs","title":"ABB Bailey IMFBS01 Field Bus Slave Module INFI 90 DCS","description":"\u003ch2\u003eABB Bailey IMFBS01 Field Bus Slave Module\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eABB Bailey IMFBS01\u003c\/strong\u003e is a Field Bus Slave (FBS) Module designed for Bailey INFI 90 and Network 90 Distributed Control Systems (DCS). It serves as a communication and signal-processing interface between field instrumentation and the system Multi-Function Processor (MFP) or Multi-Function Controller (MFC) over the I\/O Expander Bus.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIMFBS01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB Bailey\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eField Bus Slave Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n\u003ctd\u003eBailey INFI 90, Network 90\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eController Compatibility\u003c\/td\u003e\n\u003ctd\u003eMulti-Function Processor (MFP), Multi-Function Controller (MFC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Communication\u003c\/td\u003e\n\u003ctd\u003eI\/O Expander Bus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Channels\u003c\/td\u003e\n\u003ctd\u003e15 independently configurable channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Input Signals\u003c\/td\u003e\n\u003ctd\u003e4-20 mA, 0-1 VDC, 1-5 VDC, 0-5 VDC, 0-10 VDC, +\/- 10 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Modes\u003c\/td\u003e\n\u003ctd\u003eFSK Field Bus, FSK Analog Point-to-Point, Baseband Analog Point-to-Point\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupported Devices\u003c\/td\u003e\n\u003ctd\u003eBailey Smart Transmitters, Conventional Field Instruments\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Processing\u003c\/td\u003e\n\u003ctd\u003eAnalog-to-Digital Conversion\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Interface\u003c\/td\u003e\n\u003ctd\u003eTermination Unit \/ Termination Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Voltage\u003c\/td\u003e\n\u003ctd\u003e+5 VDC (+\/- 5%), +15 VDC (+\/- 5%), -15 VDC (+\/- 5%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Consumption\u003c\/td\u003e\n\u003ctd\u003e85 mA at +5 VDC, 25 mA at +15 VDC, 20 mA at -15 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Dissipation\u003c\/td\u003e\n\u003ctd\u003e1.1 W (typical)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 deg C to +70 deg C (32 deg F to 158 deg F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Type\u003c\/td\u003e\n\u003ctd\u003eINFI 90 Module Mounting Unit (MMU) \/ Rack-mounted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Construction\u003c\/td\u003e\n\u003ctd\u003eSingle Printed Circuit Board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eSignal Processing and Channel Configuration\u003c\/h3\u003e\n\u003cp\u003eThe module supports 15 independent input channels for acquiring analog process signals and communicating with smart transmitters and conventional field devices. It performs analog-to-digital conversion to translate analog inputs into digital process variables accessible by the host controller.\u003c\/p\u003e\n\u003ch3\u003eCommunication Modes\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eIMFBS01\u003c\/strong\u003e supports multiple communication formats to accommodate different field instrument types. It enables FSK field bus communication, FSK analog point-to-point communication, and baseband analog point-to-point communication, allowing bidirectional parameter modification and range adjustment on compatible smart transmitters.\u003c\/p\u003e\n\u003cp\u003eFrequently Asked Questions\u003c\/p\u003e\n\u003cp\u003eQ: Which control systems are compatible with the IMFBS01 module? A: It is compatible with Bailey INFI 90 and Network 90 Distributed Control Systems using MFP or MFC controllers over the I\/O Expander Bus.\u003c\/p\u003e\n\u003cp\u003eQ: What types of analog input signals can the module process? A: It supports 4-20 mA, 0-1 VDC, 1-5 VDC, 0-5 VDC, 0-10 VDC, and +\/- 10 VDC signals across 15 channels.\u003c\/p\u003e\n\u003cp\u003eQ: How is the module powered and mounted? A: It draws +5 VDC (85 mA), +15 VDC (25 mA), and -15 VDC (20 mA) from the backplane and installs into an INFI 90 Module Mounting Unit (MMU).\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":43781745246307,"sku":"IMFBS01","price":676.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/445.jpg?v=1760593060","url":"https:\/\/www.autocontrolglobal.com\/products\/abb-bailey-imfbs01-field-bus-slave-module-infi-90-dcs","provider":"AutoControl Global","version":"1.0","type":"link"}