{"product_id":"abb-ci860-3bse032444r1-communication-interface","title":"ABB CI860 3BSE032444R1 Communication Interface","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe ABB CI860 (catalog number 3BSE032444R1, also designated as CI860K01) is a high-performance, 100% brand new original FOUNDATION Fieldbus HSE (High-Speed Ethernet) communication interface module. This industrial networking module serves as the primary backbone gateway that connects ABB AC 800M controllers directly to distributed control networks. By linking localized process instrumentation fields with the overarching System 800xA control platform, the interface delivers high-bandwidth data transfers, deterministic process tracking, and rapid backbone data execution for complex industrial facilities.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003eThe system hardware pairs the communication processor with a dedicated baseplate to maintain network routing without consuming external cabinet resources. All technical values use standard ASCII formatting:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eManufacturer Component ID:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e3BSE032444R1\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHardware Profile Nomenclature:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eCI860 \/ CI860K01\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePrimary Communication Protocol:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFOUNDATION Fieldbus HSE (High-Speed Ethernet)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePhysical Network Connectivity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eRJ-45 Ethernet ports\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eData Transmission Velocity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUp to 100 Mbps\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSupported Network Topologies:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eLinear, star, and redundant ring structures\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSystem Software Compatibility:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eABB AC 800M controllers running control software version 6.0 or higher\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSystem Redundancy Support:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eHardware pairing routines for full fault-tolerant operation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDiagnostic Architecture:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBuilt-in advanced communication tracking and troubleshooting software tools\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Input Voltage:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e24 V DC draw drawn directly from the host controller CEX bus\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eExternal Power Supply Requirement:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eNone (powered internally via backplane)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAmbient Operating Temperature Range:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e-40 to +85 degrees Celsius\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eLong-term Storage Temperature Limits:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e-40 to +70 degrees Celsius\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRelative Humidity Workspace:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e5% to 95% non-condensing\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Net Depth \/ Length:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e127.5 mm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Net Height:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e186 mm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Net Width:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e59 mm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eNet Hardware Weight:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e0.55 to 0.7 kg\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eStandard Shipping Package Contents:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e1 x CI860 communication interface module and 1 x TP860 interface baseplate\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRegulatory Compliance Frameworks:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eCE marked, RoHS compliant, WEEE Category 5 certified\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cp\u003eThe CI860 3BSE032444R1 module overcomes critical communication bottlenecks and architectural vulnerabilities inside modern chemical, oil, and power processing plants:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEliminates Separate Controller Power Wiring:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eTraditional communication expander cards require individual 24V power drops, expanding panel clutter and increasing wire failure points. The CI860 pulls power directly from the master AC 800M controller via the integrated CEX bus architecture. This plug-and-play design speeds up installation, eliminates external power supply units (PSUs), and cleans up cable layouts.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePrevents Process Downtime via Redundant Rings:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eA single severed fiber or copper Ethernet cable can blind an entire control room to field operations. The module supports redundant ring topologies alongside standard linear or star setups. If a physical line breaks, the internal network stack reroutes data packets instantly along the backup path with zero loss of process synchronization.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProtects Critical Electronics in Weather Extremes:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eExtreme sub-zero temperatures or high summer heat waves often freeze up commercial grade switches. This rugged industrial interface module operates seamlessly across a wide temperature window from -40 all the way to +85 degrees Celsius, allowing engineers to place the control cabinets directly on remote processing skids without buying extra enclosure heaters or cooling fans.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSimplifies Complex Field Device Mapping:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eCorrelating thousands of dynamic instrument variables into a distributed control system often creates software configuration bottlenecks. This module interfaces natively with System 800xA and AC 800M engineering environments, pulling advanced diagnostics and variables directly from smart FOUNDATION Fieldbus devices into the controller logic charts without requiring manual register mapping.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is this ABB CI860 3BSE032444R1 module a factory-original item?\u003c\/strong\u003eA: Yes. We supply this product as a 100% brand new, original factory component. The box contains the pristine CI860 interface module along with its matching TP860 mounting baseplate to ensure full compliance with plant validation parameters.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does this module support legacy versions of ABB control software?\u003c\/strong\u003eA: The CI860 hardware architecture requires ABB AC 800M controller software version 6.0 or higher to unlock all high-speed Ethernet features and firmware compatibility layers.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How does the module handle communication troubleshooting without shutting down the loop?\u003c\/strong\u003eA: The module embeds advanced real-time diagnostic tools that stream bus health parameters directly to the control room interface. Operators can monitor packet drop rates, trace network traffic jitter, and identify faulty field segments on the fly without stopping active process control loops.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What installation step protects the RJ-45 Ethernet lines from plant noise?\u003c\/strong\u003eA: When snapping the CI860 onto the TP860 baseplate inside your cabinet, always utilize double-shielded, industrial-grade Cat5e or Cat6 cables with grounded metallic RJ-45 plugs. This practice grounds out stray electromagnetic fields from surrounding high-voltage motor starters and preserves the 100 Mbps data stream.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":44187575943267,"sku":"CI860 3BSE032444R1","price":340.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/194._83a8c7ba-33c2-41a6-b9ce-19b25f2557b6.jpg?v=1779094398","url":"https:\/\/www.autocontrolglobal.com\/products\/abb-ci860-3bse032444r1-communication-interface","provider":"AutoControl Global","version":"1.0","type":"link"}