{"product_id":"abb-do562-1sap230900r0000-s500-eco-digital-output-module","title":"ABB DO562 1SAP230900R0000 S500-eCo Digital Output Module","description":"\u003ch2\u003eABB DO562 S500-eCo Digital Output Module\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eABB DO562\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eDO562\u003c\/strong\u003e Digital Output Module, operates as a dedicated hardware component for switching discrete DC loads within AC500-eCo PLC networks. Engineered to convert logical internal commands into physical voltage state changes, the assembly drives field actuators, solenoids, and interposing relays via 16 transistor switching elements configured in a unified electrical group.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eDO562 (Part Number: 1SAP230900R0000)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eChina\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.16 kg net (0.219 kg gross)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e34 mm x 135 mm x 75 mm (W x H x D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to +60 deg C (horizontal mounting), 0 to +40 deg C (vertical mounting)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e1.4 W maximum power dissipation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannels\u003c\/td\u003e\n\u003ctd\u003e16 digital transistor outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Type\u003c\/td\u003e\n\u003ctd\u003eTransistor (DC switching, 1-wire configuration)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC rated (operating range: 20.4 to 28.8 VDC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Current\u003c\/td\u003e\n\u003ctd\u003eMaximum 0.5 A per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical Isolation\u003c\/td\u003e\n\u003ctd\u003eGalvanic isolation between output group and logic circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannel Grouping\u003c\/td\u003e\n\u003ctd\u003e1 group of 16 channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOvervoltage Threshold\u003c\/td\u003e\n\u003ctd\u003eClamps surge voltages up to 35 VDC for 0.5 seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVisual Indicators\u003c\/td\u003e\n\u003ctd\u003e1 yellow LED per channel for output state verification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDegree of Protection\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eIndustrial Control and Network Integration Technical Attributes\u003c\/h3\u003e\n\u003cp\u003eThe module utilizes high-density I\/O scaling to compress 16 switching circuits into a 34 mm slim form factor, optimizing spatial efficiency across decentralized automation backplanes. The internal logic communicates directly with the host controller through the S500-eCo bus architecture, verifying firmware flash compatibility profiles during the initial boot sequence.\u003c\/p\u003e\n\u003cp\u003eWhen integrated into Profinet or EtherNet\/IP deterministic networks via an upstream bus coupler, the hardware executes output updates based on fixed bus cycles, eliminating transmission lag. Physical load distribution relies on a single process supply input terminal (UP) referenced to a common zero-volt terminal (ZP). To safeguard the output circuits against overcurrent conditions, you must mount an external 3 A fast-acting fuse in the power loop, which protects the internal solid-state components during direct short-circuit events before thermal degradation occurs.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the module feature internal short-circuit protection for individual channels?\u003c\/p\u003e\n\u003cp\u003eA: No, the module requires the installation of an external 3 A fast-acting fuse on the 24 VDC process supply line to protect the transistor array. Individual channel electronic fusing is not embedded in this specific S500-eCo hardware architecture.\u003c\/p\u003e\n\u003cp\u003eQ: Can the DO562 outputs be connected in parallel to increase the total current drive capability?\u003c\/p\u003e\n\u003cp\u003eA: No, parcellation of transistor outputs to drive a single high-current load is not supported due to microscopic switching delays between channels, which can cause instantaneous overcurrent failure on the fastest-responding transistor.\u003c\/p\u003e\n\u003cp\u003eQ: What is the impact of vertical DIN-rail mounting on the environmental specifications of this module?\u003c\/p\u003e\n\u003cp\u003eA: Vertical mounting restricts natural convection air circulation across the housing vents. Consequently, you must derate the maximum operating ambient temperature limit to +40 deg C, down from the standard +60 deg C horizontal rating.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDIN-Rail Mounting Stability:\u003c\/strong\u003e Fix the module firmly onto a standard symmetric TH35 DIN rail. Engage the rear locking slide completely to ensure resistance against mechanical vibration and shock.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShielding and Grounding Standards:\u003c\/strong\u003e Route all DC output signal conductors away from high-voltage AC cabling. Ensure the functional earth connection of the AC500-eCo terminal block connects directly to the central panel earth bar using a low-impedance conductor.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring Configurations:\u003c\/strong\u003e Connect field loads using a 1-wire configuration, running the positive switched line from the module terminal and terminating the return side directly at the common ZP distribution block.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThermal Management:\u003c\/strong\u003e Maintain a minimum clear space of 50 mm above and below the module housing to prevent obstruction of natural convection cooling currents.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":44406677766243,"sku":"DO562 1SAP230900R0000","price":650.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/706..jpg?v=1785140735","url":"https:\/\/www.autocontrolglobal.com\/products\/abb-do562-1sap230900r0000-s500-eco-digital-output-module","provider":"AutoControl Global","version":"1.0","type":"link"}