{"product_id":"abb-ec-bom-g009hla111-uvisor-sf-fau-infrared-flame-scanner","title":"ABB EC-BOM-G009HLA111 Uvisor SF\/FAU Infrared Flame Scanner","description":"\u003ch2\u003eABB EC-BOM-G009HLA111 Uvisor SF\/FAU Series Infrared Flame Scanner\u003c\/h2\u003e\n\u003cp\u003eConfigured for continuous combustion flame radiation detection in industrial burner monitoring systems, the \u003cstrong\u003eABB EC-BOM-G009HLA111\u003c\/strong\u003e (\u003cstrong\u003eEC-BOM-G009HLA111\u003c\/strong\u003e Infrared Flame Scanner Module) provides direct physical\/electrical execution. It functions as an optical sensor unit within ABB Uvisor SF and FAU controller architectures, capturing raw infrared flicker frequencies emitted by fuel combustion processes and transferring proportional raw flame signals to downstream processing units.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eEC-BOM-G009HLA111\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCatalog Description\u003c\/td\u003e\n\u003ctd\u003eUR600 IR Mod.1000 senza lente, con ghiera\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Family\u003c\/td\u003e\n\u003ctd\u003eCombustion Instruments - Uvisor SF\/FAU Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Type\u003c\/td\u003e\n\u003ctd\u003eInfrared Flame Scanner Unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Dimensions (W x H x D)\u003c\/td\u003e\n\u003ctd\u003e180 mm x 150 mm x 67 mm (7.09 in x 5.91 in x 2.64 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGross Package Weight\u003c\/td\u003e\n\u003ctd\u003e1573 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Configuration\u003c\/td\u003e\n\u003ctd\u003eExternal Retaining Ring Included (Lens Not Included)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003eStandard Industrial Range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eSystem Backplane Dependent \/ Controller Powered\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Output Type\u003c\/td\u003e\n\u003ctd\u003eRaw Infrared Flame Flicker Signal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOptical Spectrum\u003c\/td\u003e\n\u003ctd\u003eInfrared (IR)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCustoms Tariff Number\u003c\/td\u003e\n\u003ctd\u003e9031809090\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWEEE Category\u003c\/td\u003e\n\u003ctd\u003eCategory 5 - Small Equipment (no external dimension \u0026gt;50 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Communication \u0026amp; I\/O Scaling Profiles\u003c\/h3\u003e\n\u003cp\u003eThe module interfaces directly with Uvisor SF and FAU control platforms, delivering precise raw signal values over backplane bus communication lines. Internal signal scaling maintains low attenuation across variable flame intensity profiles, suppressing signal noise and optical cross-talk generated by adjacent burner flames. Firmware flash compatibility ensures seamless integration with Uvisor monitoring units, enabling high-density signal evaluation without introducing processing latencies.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the EC-BOM-G009HLA111 module include integrated focusing optics upon delivery?\u003c\/p\u003e\n\u003cp\u003eA: No. The unit is supplied without an internal optical lens (\"senza lente\") but incorporates a factory retaining ring (\"con ghiera\") to accept specific lens assemblies suited to burner sight tube geometry.\u003c\/p\u003e\n\u003cp\u003eQ: What optical spectrum and signal characteristics does the scanner evaluate?\u003c\/p\u003e\n\u003cp\u003eA: The scanner detects infrared flicker radiation generated by target flames and transmits the unconditioned raw AC\/DC signal directly to the evaluation controller.\u003c\/p\u003e\n\u003cp\u003eQ: Can this scanner module be hot-swapped during active burner management system operations?\u003c\/p\u003e\n\u003cp\u003eA: Field replacement requires power isolation or verification of safe backplane bus removal parameters specified by the parent Uvisor system enclosure to prevent transient signal faults.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eEnsure proper mechanical alignment of the housing with the burner sight path to maintain direct line-of-sight with the primary ignition zone.\u003c\/li\u003e\n\u003cli\u003eTorque the optical retaining ring to vendor-recommended limits to prevent optical misalignment caused by continuous structural combustion vibration.\u003c\/li\u003e\n\u003cli\u003eEstablish a single-point continuous shield ground for signal cabling to eliminate ground loops and minimize electromagnetic interference from high-voltage ignition transformers.\u003c\/li\u003e\n\u003cli\u003eVerify sight tube cooling air purge pressure before continuous thermal exposure to maintain housing temperatures within specified operating limits.\u003c\/li\u003e\n\u003cli\u003eRoute low-level raw signal wiring in dedicated, grounded metallic conduits separate from three-phase AC power lines or heavy motor drives.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":43838446698595,"sku":"EC-BOM-G009HLA111","price":676.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/368_02a464bc-1e29-4809-86b5-a01c9d9c46b8.jpg?v=1763105496","url":"https:\/\/www.autocontrolglobal.com\/products\/abb-ec-bom-g009hla111-uvisor-sf-fau-infrared-flame-scanner","provider":"AutoControl Global","version":"1.0","type":"link"}