{"product_id":"abb-pm860k01-advant-800xa-ac800m-controller-processor-unit","title":"ABB PM860K01 Advant 800xA AC800M Controller Processor Unit","description":"\u003ch2\u003eABB PM860K01 Processor Unit Kit\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eABB PM860K01\u003c\/strong\u003e (\u003cstrong\u003ePM860\u003c\/strong\u003e Processor Unit), serves as the primary \u003cstrong\u003ePM860\u003c\/strong\u003e Processor Module utilized to execute control logic and manage communication across ABB AC 800M platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003ePM860K01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eSweden\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.92 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e190 mm x 120 mm x 132 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e+5 to +55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e5 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCPU Memory\u003c\/td\u003e\n\u003ctd\u003e16 MB Program \/ 16 MB Data\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEthernet Ports\u003c\/td\u003e\n\u003ctd\u003e2 x 10\/100 Mbps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Class\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eIndustrial Control \u0026amp; Processing\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003ePM860\u003c\/strong\u003e architecture manages complex control loops through dedicated industrial processing hardware, ensuring high-speed cycle time execution within the AC 800M environment. The module firmware provides native support for CPU redundancy, allowing paired synchronization when two modules operate in a high-availability configuration. System communication relies on the deterministic CEX-bus backplane, which facilitates low-latency data exchange with I\/O modules and communication interfaces such as the CI854 or CI867. Firmware flash compatibility is managed via the Control Builder interface, ensuring alignment with 800xA control system software versions.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the PM860K01 processor support redundant CPU operation?\u003c\/p\u003e\n\u003cp\u003eA: Yes, the module supports redundancy when paired with a secondary PM860 processor, facilitating seamless failover transitions for high-availability control applications.\u003c\/p\u003e\n\u003cp\u003eQ: What are the requirements for firmware updates on this unit?\u003c\/p\u003e\n\u003cp\u003eA: Firmware updates are performed through the Control Builder configuration software. Users must ensure the binary image matches the specific hardware revision of the PM860 module to prevent configuration errors.\u003c\/p\u003e\n\u003cp\u003eQ: Can this unit be hot-swapped during operation?\u003c\/p\u003e\n\u003cp\u003eA: While CEX-bus communication modules support hot-swapping, the primary processor unit requires a controlled shutdown or a transition to a standby state before physical removal from the TP830 baseplate to avoid process interruption.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBaseplate Mounting:\u003c\/strong\u003e Secure the TP830 baseplate to a horizontal or vertical DIN rail. Ensure the baseplate is properly grounded to the cabinet chassis to provide an effective return path for electrical noise.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModule Insertion:\u003c\/strong\u003e Align the PM860 module with the TP830 guide rails. Slide the module into position until the CEX-bus connectors are fully seated and the mechanical latch clicks into the locked position.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEthernet Connectivity:\u003c\/strong\u003e Use shielded Cat5e or Cat6 cables for CN1 and CN2 ports. Verify that the cable runs maintain a minimum separation distance from high-voltage power lines to prevent signal induction.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Supply:\u003c\/strong\u003e Connect a regulated 24 VDC power source to the baseplate. Verify that the input voltage remains within the specified operating tolerance before initiating the processor boot sequence.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":44314162593891,"sku":"PM860K01 3BSE018100R1","price":650.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/193_e1de5a8f-ea7e-4e8e-994d-8185d5f3fba4.jpg?v=1783070259","url":"https:\/\/www.autocontrolglobal.com\/products\/abb-pm860k01-advant-800xa-ac800m-controller-processor-unit","provider":"AutoControl Global","version":"1.0","type":"link"}