{"product_id":"abb-pm867k02-3bse081638r1-ac-800m-controller-module","title":"ABB PM867K02 3BSE081638R1 AC 800M Controller Module","description":"\u003ch2\u003eABB PM867K02 AC 800M Controller Module\u003c\/h2\u003e\n\u003cp\u003eConfigured for high-availability process control and safety-related execution in ABB 800xA distributed control systems, the \u003cstrong\u003eABB PM867K02\u003c\/strong\u003e (\u003cstrong\u003ePM867\u003c\/strong\u003e Controller Module) provides direct physical\/electrical execution.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003ePM867K02\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct ID\u003c\/td\u003e\n\u003ctd\u003e3BSE081638R1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eSweden\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProcessor\u003c\/td\u003e\n\u003ctd\u003e133 MHz industrial CPU (MPC866)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMemory\u003c\/td\u003e\n\u003ctd\u003e64 MB RAM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRedundancy\u003c\/td\u003e\n\u003ctd\u003eDual CPU with automatic failover\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Certification\u003c\/td\u003e\n\u003ctd\u003eSIL3 (IEC 61508)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e24 VDC (19.2 to 30 VDC input range)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 deg C to +55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard AC 800M module chassis\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e2.7 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e24 VDC nominal, load dependent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eHardware Communications and Firmware Flash Compatibility\u003c\/h3\u003e\n\u003cp\u003eThe module executes real-time diagnostics and control coordination via its dedicated backplane connections and physical ports. System engineers must verify firmware flash compatibility between the PM867K02 dual-processor unit and the integrated CEX (Communication Expansion) bus modules to prevent communication timeouts during configuration updates. Synchronized peer-to-peer data transfers over the redundant Control Network (CN1, CN2) rely on verified flash image states to maintain deterministic network switchovers during physical hardware faults.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the PM867K02 controller support module replacement under live backplane power?\u003c\/p\u003e\n\u003cp\u003eA: Yes, the module supports online hot-swapping. The host backplane interface allows terminal replacement of a faulty unit without interrupting processing on the active partner CPU.\u003c\/p\u003e\n\u003cp\u003eQ: What are the minimum system software constraints required to commission this hardware?\u003c\/p\u003e\n\u003cp\u003eA: The PM867K02 requires ABB 800xA system software version 6.0.2 or later to establish full parameterization, network routing, and diagnostic monitoring.\u003c\/p\u003e\n\u003cp\u003eQ: How does the module maintain its runtime memory configuration during an input power failure?\u003c\/p\u003e\n\u003cp\u003eA: The hardware package includes two backup batteries that power the internal volatile RAM, preserving application code and variable states during complete loss of the 24 VDC system power.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBaseplate and Terminator Alignment:\u003c\/strong\u003e Mount the dual modules onto the TP830 baseplates, and secure the TB807 ModuleBus terminators at the physical ends of the assembly to prevent signal reflections.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRCU-Link Connection:\u003c\/strong\u003e Connect the redundant CPUs using the TK851 RCU-Link cable to establish high-speed memory synchronization between the primary and backup controllers.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding Requirements:\u003c\/strong\u003e Ensure the DIN rail or mounting subpanel has a low-impedance connection to the local instrument earth (less than 1 Ohm) to minimize common-mode noise on the serial and Ethernet ports.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable Strain Relief:\u003c\/strong\u003e Secure all RJ45 Ethernet and CEX cables to the cabinet structure to prevent mechanical stress from damaging the internal communication ports.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":43865643188323,"sku":"PM867K02 3BSE081638R1","price":676.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/133_fecc950b-214d-47ea-804c-1e66bb190272.jpg?v=1764577137","url":"https:\/\/www.autocontrolglobal.com\/products\/abb-pm867k02-3bse081638r1-ac-800m-controller-module","provider":"AutoControl Global","version":"1.0","type":"link"}