ABB REC670 1MRK000008-HB Bay Control Intelligent Electronic Device
ABB REC670 1MRK000008-HB Bay Control Intelligent Electronic Device
ABB REC670 1MRK000008-HB Bay Control Intelligent Electronic Device
/ 3

ABB REC670 1MRK000008-HB Bay Control Intelligent Electronic Device

  • Manufacturer: ABB

  • Part Number: REC670 1MRK000008-HB

  • Condition:New with Original Package

  • Product Type: Bay Control IEDs

  • Country of Origin: USA

  • Payment:T/T, Western Union

  • Shipping port: Xiamen

  • Warranty: 12 months

ABB REC670 1MRK000008-HB Bay Control IED

The ABB REC670 1MRK000008-HB, also cataloged as the REC670 Bay Control IED, operates as a dedicated hardware component for substation bay control, breaker interlocking, and process measurement within AIS and GIS switchgear platforms.

Hardware Specifications

Parameter Specification
Model REC670 1MRK000008-HB
Brand ABB
Origin China
Weight 2.1 kg
Dimensions Rack mount standard chassis
Operating Temp -25 deg C to +55 deg C
Power Consumption Not specified
Core Performance Bay Control, Auto-reclose, Breaker Failure, PRP/HSR

Industrial Control and Firmware Compatibility

The REC670 belongs to the Relion 670 series, providing integrated bay control and protection logic. The IED supports firmware flash compatibility, ensuring that station-level communication protocols—including IEC 61850 Editions 1 and 2—remain aligned with system automation requirements. The architecture supports backplane bus communication velocity sufficient for deterministic GOOSE messaging and high-speed breaker interlocking sequences. Users can optimize system performance by utilizing the I/O density scaling capabilities to match the physical switchgear arrangement, whether in single, double, or one-and-a-half breaker configurations. Time synchronization is maintained via IEEE 1588 V2 to ensure accurate event sequence recording across distributed substation networks.

Frequently Asked Questions

Q: Does the REC670 support hot-swapping of individual I/O modules?

A: The REC670 modular design facilitates hardware maintenance; however, removing I/O modules while the unit is energized will trigger an internal hardware fault and interrupt the associated control and monitoring functions for that specific bay.

Q: Is the HMI module configurable for different language and character sets?

A: The local HMI supports graphical single-line diagram (SLD) rendering and text-based event logs. Configuration and display parameters are managed through the ABB PCM600 tool suite, which allows for customization of the user interface.

Field Installation Guidelines

  1. Mounting: Secure the IED into the 19-inch switchgear rack. Ensure the rear mechanical latches are locked to maintain reliable contact with the backplane connector pins.
  2. Wiring: Route signal cables through designated cable management ducts, keeping analog sensing leads separated from high-current binary I/O lines to reduce electromagnetic interference.
  3. Grounding: Connect the rear chassis protective earth (PE) terminal to the substation common ground grid using a high-flexibility copper cable to ensure proper dissipation of transient currents.
  4. Communication: When deploying PRP or HSR rings, verify that all fiber optic or Ethernet connections adhere to the network topology specifications to prevent circular paths and data collision.