{"product_id":"abb-rem615c_d-relion-615-motor-protection-and-control-relay","title":"ABB REM615C_D Relion 615 Motor Protection and Control Relay","description":"\u003ch2\u003eABB REM615C_D Relion 615 Motor Protection Relay\u003c\/h2\u003e\n\u003cp\u003eConfigured for medium-voltage motor monitoring and control in industrial distribution networks, the \u003cstrong\u003eABB REM615C_D HCMBCCAHABB2BNN11E\u003c\/strong\u003e (\u003cstrong\u003eREM615C_D\u003c\/strong\u003e Motor Protection Relay) provides direct physical and electrical execution of protection logic and switchgear management.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eREM615C_D HCMBCCAHABB2BNN11E\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eSweden\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.0 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eRack\/Cabinet mount plug-in unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-25 deg C to +55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eNot specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCore Performance\u003c\/td\u003e\n\u003ctd\u003eThermal overload, locked rotor, load loss, motor reversal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eIndustrial Control and Firmware Compatibility\u003c\/h3\u003e\n\u003cp\u003eThe REM615C_D integrates protection, control, and measurement functions within the Relion 615 series architecture. The module supports backplane bus communication velocity and firmware flash compatibility, facilitating seamless integration with existing station-level automation systems. Deterministic networking is achieved through native support for IEC 61850 Edition 1 and 2, including GOOSE messaging and PRP\/HSR redundancy protocols. Users must ensure that the relay configuration matches the motor nameplate data and that the I\/O density scaling is verified during commissioning to accommodate the required binary input and output assignments. Time synchronization is enforced via IEEE 1588 v2 (PTP) to ensure accurate event log and disturbance recording across the substation network.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the REM615C_D support hot-swapping during active service?\u003c\/p\u003e\n\u003cp\u003eA: The relay is designed as a plug-in unit; however, removing the unit from the rack interrupts protection functions for the associated motor. Always ensure the motor is isolated and the relay is bypassed or the trip circuit is disabled before physical removal.\u003c\/p\u003e\n\u003cp\u003eQ: How is the GOOSE messaging latency managed in a redundant PRP network?\u003c\/p\u003e\n\u003cp\u003eA: The relay handles GOOSE messaging over PRP\/HSR architectures to achieve near-zero recovery time. Latency is governed by the switchgear network configuration and the IEEE 1588 time synchronization settings applied to the relay ports.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Insert the relay unit into the designated switchgear rack slot. Tighten the retaining screws to ensure the connector pins interface securely with the rear terminals.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding:\u003c\/strong\u003e Bond the relay chassis to the cabinet grounding bar using a high-flexibility, low-impedance copper strap to provide a stable reference for internal electronics and surge suppression.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnectivity:\u003c\/strong\u003e Connect the fiber optic or Ethernet cabling for IEC 61850 communication. Ensure bend radii for cables are maintained to avoid signal attenuation in high-speed PRP\/HSR rings.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring:\u003c\/strong\u003e Route binary I\/O signals and CT\/VT wiring through separate wire ducts to prevent crosstalk between high-voltage sensing circuits and low-voltage control signals.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":44342582837347,"sku":"REM615C_D HCMBCCAHABB2BNN11E","price":400.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/414._f2d928bf-47bb-440e-9da6-6d219ade1a30.jpg?v=1783569618","url":"https:\/\/www.autocontrolglobal.com\/products\/abb-rem615c_d-relion-615-motor-protection-and-control-relay","provider":"AutoControl Global","version":"1.0","type":"link"}