{"product_id":"abb-sa9923a-e-hiee450964r1-high-voltage-control-board-module","title":"ABB SA9923a-E HIEE450964R1 High Voltage Control Board Module","description":"\u003ch2\u003eABB SA9923a-E HIEE450964R1 High-Voltage Control Board\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eABB SA9923a-E\u003c\/strong\u003e (Part Number: HIEE450964R1) is a high-voltage control board designed for industrial automation, inverter systems, and electrical substations. It handles voltage regulation and fault monitoring for control circuits rated up to 6.6 kV, interfacing with host systems via a multi-pin backplane connector.\u003c\/p\u003e\n\u003ch3\u003eElectrical Ratings and Protection\u003c\/h3\u003e\n\u003cp\u003eOperating from a 24 VDC (+\/-10%) auxiliary supply with a typical power consumption of 12 W, the board supports control circuit voltages up to 6.6 kV and current handling up to 15 A. Its insulation resistance exceeds 1000 MOhm at 100 VDC to maintain isolation between high-voltage circuits and low-voltage control logic.\u003c\/p\u003e\n\u003cp\u003eBuilt-in protection mechanisms include electrical isolation, surge suppression, and thermal protection. Diagnostic functions continuously monitor for overvoltage and short-circuit conditions while performing internal self-checks, achieving a response time under 10 ms.\u003c\/p\u003e\n\u003ch3\u003ePhysical and Environmental Specifications\u003c\/h3\u003e\n\u003cp\u003eThe board connects to the host rack through a multi-pin backplane interface and supports communication across proprietary and standard fieldbus systems. It is rated for operation in ambient temperatures from -20 deg C to +70 deg C and storage from -40 deg C to +85 deg C.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eSA9923a-E\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003eHIEE450964R1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eHigh-Voltage Control Board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Voltage\u003c\/td\u003e\n\u003ctd\u003eUp to 6.6 kV (control circuit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Handling\u003c\/td\u003e\n\u003ctd\u003eUp to 15 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation Resistance\u003c\/td\u003e\n\u003ctd\u003eGreater than 1000 MOhm at 100 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e24 VDC (+\/-10%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e12 W typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResponse Time\u003c\/td\u003e\n\u003ctd\u003eLess than 10 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl Interface\u003c\/td\u003e\n\u003ctd\u003eMulti-pin backplane connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiagnostic Features\u003c\/td\u003e\n\u003ctd\u003eOvervoltage detection, short-circuit monitoring, self-check\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Features\u003c\/td\u003e\n\u003ctd\u003eElectrical isolation, surge suppression, thermal protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-20 deg C to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 deg C to +85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (L x W x H)\u003c\/td\u003e\n\u003ctd\u003e280 mm x 180 mm x 35 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.15 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCountry of Origin\u003c\/td\u003e\n\u003ctd\u003eSweden\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What are the maximum voltage and current ratings for the ABB SA9923a-E control circuit? A: The board is rated for control circuit voltages up to 6.6 kV and current handling up to 15 A.\u003c\/p\u003e\n\u003cp\u003eQ: What auxiliary power supply is required to operate this control board? A: It requires a 24 VDC supply within a +\/-10% tolerance, drawing a typical power of 12 W.\u003c\/p\u003e\n\u003cp\u003eQ: What fault diagnostic and protection features are integrated into the HIEE450964R1? A: It includes overvoltage detection, short-circuit monitoring, self-check diagnostics, electrical isolation, surge suppression, and thermal protection with a response time under 10 ms.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":43782150094947,"sku":"SA9923a-E HIEE450964R1","price":676.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/477._c2564f3a-df2c-4be6-a3ad-a5123dbe2db5.jpg?v=1794566681","url":"https:\/\/www.autocontrolglobal.com\/products\/abb-sa9923a-e-hiee450964r1-high-voltage-control-board-module","provider":"AutoControl Global","version":"1.0","type":"link"}