{"product_id":"abe7r16t330-schneider-telefast-16-ch-relay-sub-base","title":"ABE7R16T330 | Schneider Telefast 16-Ch Relay Sub-base","description":"\u003ch2\u003eSchneider Electric ABE7R16T330 Telefast Relay Sub-base\u003c\/h2\u003e\n\u003cp\u003eThe Schneider Electric \u003cstrong\u003eABE7R16T330\u003c\/strong\u003e is a 16-channel output relay sub-base in the Telefast ABE7 connection system. It interfaces PLC output modules with field loads through plug-in electromechanical relays with 1 C\/O changeover contacts. Each channel includes a green status LED and 2 A fast-acting fuse protection, supporting DIN rail or screw mounting and screw-terminal field connections.\u003c\/p\u003e\n\u003ch3\u003eSwitching and Protection Architecture\u003c\/h3\u003e\n\u003cp\u003eEach of the 16 channels switches loads up to 2 A through a 1 C\/O (SPDT) contact arrangement paired with a 2 A fast-acting 5 x 20 mm fuse (0.3 V fuse voltage drop). A 1 A fast-blow internal fuse protects the PLC side, while a power LED and 16 channel LEDs support local status checks.\u003c\/p\u003e\n\u003cp\u003eThe module operates with volt-free polarity distribution and specifies 2000 V rated insulation voltage between terminals and mounting rail, 300 V coil-to-contact insulation, and 2.5 kV impulse withstand voltage.\u003c\/p\u003e\n\u003ch3\u003eWiring and Mounting Details\u003c\/h3\u003e\n\u003cp\u003eField circuits wire to screw terminals tightened to 0.6 N.m using a 3.5 mm flat screwdriver. Supported conductor ranges cover 0.09-1.5 mm2 (single flexible), 0.14-2.5 mm2 (single solid), 2 x 0.09-0.75 mm2 (double flexible), and 2 x 0.2-2.5 mm2 (double solid).\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eCompatible with plug-in electromechanical relay model ABR7S33.\u003c\/li\u003e\n\u003cli\u003eConnects to PLC systems via pre-wired interfaces, including HE10-type connections.\u003c\/li\u003e\n\u003cli\u003eMounts on a 35 mm DIN rail or via screw fixing inside an IP2X-rated enclosure.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eABE7R16T330\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Series\u003c\/td\u003e\n\u003ctd\u003eModicon ABE7 \/ Advantys Telefast\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eRelay Sub-base (Output Sub-base)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Channels\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelay Type\u003c\/td\u003e\n\u003ctd\u003ePlug-in electromechanical relay\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible Relay\u003c\/td\u003e\n\u003ctd\u003eABR7S33\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContact Configuration\u003c\/td\u003e\n\u003ctd\u003e1 C\/O (SPDT)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContact Rating\u003c\/td\u003e\n\u003ctd\u003e2 A per channel (fuse protected)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoil Supply Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC (19-30 VDC listed in source)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Supply Current\u003c\/td\u003e\n\u003ctd\u003e1 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePolarity Distribution\u003c\/td\u003e\n\u003ctd\u003eVolt-free\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Fuse\u003c\/td\u003e\n\u003ctd\u003e2 A fast-acting \/ fast-blow, 5 x 20 mm per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFuse Voltage Drop\u003c\/td\u003e\n\u003ctd\u003e0.3 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePLC-Side Protection\u003c\/td\u003e\n\u003ctd\u003e1 A fast-blow internal fuse\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLED Indicators\u003c\/td\u003e\n\u003ctd\u003e1 green power LED, 16 green channel LEDs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Insulation Voltage (Ui)\u003c\/td\u003e\n\u003ctd\u003e2000 V (terminals \/ mounting rail)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoil-to-Contact Insulation\u003c\/td\u003e\n\u003ctd\u003e300 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eImpulse Withstand Voltage\u003c\/td\u003e\n\u003ctd\u003e2.5 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnection \/ Terminal Type\u003c\/td\u003e\n\u003ctd\u003eScrew terminals (HE10 pre-wired PLC interface noted)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWire Capacity (Single Flexible)\u003c\/td\u003e\n\u003ctd\u003e0.09-1.5 mm2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWire Capacity (Single Solid)\u003c\/td\u003e\n\u003ctd\u003e0.14-2.5 mm2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWire Capacity (Double Flexible)\u003c\/td\u003e\n\u003ctd\u003e2 x 0.09-0.75 mm2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWire Capacity (Double Solid)\u003c\/td\u003e\n\u003ctd\u003e2 x 0.2-2.5 mm2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTightening Torque\u003c\/td\u003e\n\u003ctd\u003e0.6 N.m (3.5 mm flat screwdriver)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003e35 mm DIN rail or screw fixing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIngress Protection\u003c\/td\u003e\n\u003ctd\u003eIP2X\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0-60 deg C (-5 to +60 deg C listed in source)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 to +85 deg C (-40 to +80 deg C listed in source)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.7 kg (approx. 1.3 kg listed in source)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompliance\u003c\/td\u003e\n\u003ctd\u003eIEC 61131-2, UL, CSA, CE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003cp\u003eFrequently Asked Questions\u003c\/p\u003e\n\u003cp\u003eQ: Which replacement relay and fuses apply to the ABE7R16T330? A: The sub-base uses compatible plug-in relay ABR7S33 and 5 x 20 mm 2 A fast-acting fuses on each channel, with a 1 A fast-blow fuse on the PLC side. Replace fuses and relays with matching ratings when de-energized.\u003c\/p\u003e\n\u003cp\u003eQ: How do the LEDs and fuses assist maintenance on this sub-base? A: Each channel has a green LED to indicate channel state alongside a green power indicator, while individual 2 A channel fuses and the 1 A PLC-side fuse isolate overcurrent faults.\u003c\/p\u003e","brand":"Schneider","offers":[{"title":"Default Title","offer_id":43883324866659,"sku":"ABE7R16T330","price":267.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/21_2fdcff48-0ecf-4267-9e3e-174e22ff0413.jpg?v=1765419215","url":"https:\/\/www.autocontrolglobal.com\/products\/abe7r16t330-schneider-telefast-16-ch-relay-sub-base","provider":"AutoControl Global","version":"1.0","type":"link"}