{"product_id":"abl8rps24100-phaseo-240w-power-supply-schneider","title":"ABL8RPS24100 Phaseo 240W Power Supply | Schneider","description":"\u003ch2\u003eSchneider Electric ABL8RPS24100 Phaseo Power Supply\u003c\/h2\u003e\n\u003cp\u003eThe Schneider Electric \u003cstrong\u003eABL8RPS24100\u003c\/strong\u003e is a 240 W regulated switch-mode power supply in the Phaseo series, delivering 24 VDC at 10 A for PLC, sensor, relay, and actuator circuits. It accepts single-phase AC (100-120 VAC or 100-240 VAC per source), phase-to-phase AC (200-500 VAC), and 110-220 VDC inputs. Key features include 24-28.8 VDC output adjustment, a 1.5 x In (15 A) 4-second boost, an integrated PFC \/ anti-harmonic filter, and parallel or series output coupling.\u003c\/p\u003e\n\u003ch3\u003eInput, Output, and Protection Characteristics\u003c\/h3\u003e\n\u003cp\u003eWide-range AC input operation at 47-63 Hz supports direct connection to single-phase mains or 400\/480 VAC phase-to-phase supplies without step-down transformers. An integrated low-frequency anti-harmonic \/ PFC filter limits line harmonics, with inrush current of 30-35 A and 31 W power dissipation.\u003c\/p\u003e\n\u003cp\u003eOn the load side, output voltage adjusts from 24 to 28.8 VDC to compensate for cable voltage drop, while a 150% (15 A) boost for 4 s handles transient inrush loads. Electronic protection covers overload and short-circuit (manual or automatic reset), thermal fault (automatic reset), overvoltage (30-32 VDC, manual reset), and undervoltage shutdown (below 21.6 VDC).\u003c\/p\u003e\n\u003ch3\u003eMechanical and Operating Conditions\u003c\/h3\u003e\n\u003cp\u003eHoused in an IP20 enclosure measuring 125 x 86 x 145 mm (H x W x D) and weighing 1.0 kg, the unit mounts on a 35 mm DIN rail or panel. LED indicators provide local status monitoring, and outputs support parallel or series coupling. Full-load operation runs from -20 to +45 deg C, with derating up to +60 deg C.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eABL8RPS24100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Series\u003c\/td\u003e\n\u003ctd\u003ePhaseo \/ Modicon Power Supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eRegulated Switch-Mode Power Supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Input Voltage\u003c\/td\u003e\n\u003ctd\u003e100-120 VAC (single-phase) \/ 100-240 VAC (first source), 200-500 VAC (phase-to-phase), 110-220 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage Limits\u003c\/td\u003e\n\u003ctd\u003e85-132 VAC \/ 170-550 VAC (85-264 VAC, 100-250 VDC in first source)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Frequency\u003c\/td\u003e\n\u003ctd\u003e47-63 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInrush Current\u003c\/td\u003e\n\u003ctd\u003e30-35 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Factor\u003c\/td\u003e\n\u003ctd\u003e0.68 at 240 VAC \/ 0.69 at 120 VAC (0.65 in first source)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHarmonic Filtering\u003c\/td\u003e\n\u003ctd\u003eIntegrated anti-harmonic \/ PFC filter (low-frequency harmonics)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEfficiency\u003c\/td\u003e\n\u003ctd\u003e85% - 87%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Dissipation\u003c\/td\u003e\n\u003ctd\u003e31 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Output Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAdjustable Output Voltage\u003c\/td\u003e\n\u003ctd\u003e24-28.8 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Output Current\u003c\/td\u003e\n\u003ctd\u003e10 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemporary Current Boost\u003c\/td\u003e\n\u003ctd\u003e1.5 x In \/ 150% (15 A) for 4 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Power\u003c\/td\u003e\n\u003ctd\u003e240 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Coupling\u003c\/td\u003e\n\u003ctd\u003eParallel or series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOverload Protection\u003c\/td\u003e\n\u003ctd\u003eManual or automatic reset\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShort-Circuit Protection\u003c\/td\u003e\n\u003ctd\u003eManual or automatic reset\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOvervoltage Protection\u003c\/td\u003e\n\u003ctd\u003e30-32 VDC, manual reset\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUndervoltage Protection\u003c\/td\u003e\n\u003ctd\u003eShutdown below 21.6 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThermal Protection\u003c\/td\u003e\n\u003ctd\u003eAutomatic reset\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStatus Indicators\u003c\/td\u003e\n\u003ctd\u003eLED indicators\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003e35 mm DIN rail or panel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIngress Protection\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-20 to +45 deg C (no derating), up to +60 deg C with derating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 to +85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (H x W x D)\u003c\/td\u003e\n\u003ctd\u003e125 x 86 x 145 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e1.0 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMarking\u003c\/td\u003e\n\u003ctd\u003eCE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch4\u003eFrequently Asked Questions\u003c\/h4\u003e\n\u003cp\u003eQ: Can the ABL8RPS24100 operate on both single-phase and phase-to-phase AC supplies? A: Yes, it accepts single-phase AC (100-120 VAC \/ 100-240 VAC per source) as well as 200-500 VAC phase-to-phase AC and 110-220 VDC inputs at 47-63 Hz.\u003c\/p\u003e\n\u003cp\u003eQ: Does the ABL8RPS24100 support parallel or series output connection? A: Yes, the output stage supports both parallel and series coupling configurations, alongside a 24-28.8 VDC adjustment range.\u003c\/p\u003e\n\u003cp\u003eQ: How do the protection functions reset after a fault on the ABL8RPS24100? A: Overload and short-circuit protections support manual or automatic reset, thermal protection resets automatically, overvoltage protection (30-32 VDC) requires manual reset, and undervoltage shuts down below 21.6 VDC.\u003c\/p\u003e","brand":"Schneider","offers":[{"title":"Default Title","offer_id":43883596284003,"sku":"ABL8RPS24100","price":267.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/30_eba78dbf-c107-4570-986d-b1bc16088b0a.jpg?v=1765422179","url":"https:\/\/www.autocontrolglobal.com\/products\/abl8rps24100-phaseo-240w-power-supply-schneider","provider":"AutoControl Global","version":"1.0","type":"link"}