{"product_id":"adv169-p00-yokogawa-centum-vp-digital-input-module","title":"ADV169-P00 Yokogawa CENTUM VP Digital Input Module","description":"\u003ch2\u003eYokogawa ADV169-P00 Digital Input Modules\u003c\/h2\u003e\n\u003cp\u003eConfigured for contact and status input processing in Yokogawa CENTUM CS and CENTUM VP platforms, the \u003cstrong\u003eYokogawa ADV169-P00\u003c\/strong\u003e (\u003cstrong\u003eADV169\u003c\/strong\u003e Digital Input Module) provides direct physical signal acquisition from field contacts and DC voltage logic circuits.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eBase Model\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSuffix \/ Option Code\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDescription \/ Specification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eADV169\u003c\/td\u003e\n\u003ctd\u003e-P00\u003c\/td\u003e\n\u003ctd\u003eStandard isolated digital input module configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eADV169-P00 (Base Model: ADV169)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e25 mm x 203 mm x 152 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e800 mA at 5 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Channels\u003c\/td\u003e\n\u003ctd\u003e64 channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Isolation\u003c\/td\u003e\n\u003ctd\u003eCommon minus side every 16 channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Signal (Contact)\u003c\/td\u003e\n\u003ctd\u003eOFF: 100 k-ohm or more; ON: 200 ohm or less\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Contact Current\u003c\/td\u003e\n\u003ctd\u003e1.25 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Signal (Voltage)\u003c\/td\u003e\n\u003ctd\u003eOFF: 4.5 to 25 VDC; ON: +\/-1 VDC, 200 ohm or less\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Response Time\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;= 8 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExternal Cable Interface\u003c\/td\u003e\n\u003ctd\u003eDedicated KS9 cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProcess Control \u0026amp; Channel-to-Channel Isolation Architecture\u003c\/h3\u003e\n\u003cp\u003eYokogawa CENTUM control systems utilize channel-to-channel isolation architecture to prevent loop interference across high-density field wiring networks. The internal input circuitry routes incoming contact or DC voltage status signals through optocoupler stages, establishing galvanic isolation between field terminal buses and internal system backplane logic. Grouping channels with a shared common minus rail every 16 points maintains robust signal segregation across all 64 channels, suppressing noise coupling and protecting control processors from field-side voltage transients.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What interconnect hardware interfaces field signals to the module?\u003c\/p\u003e\n\u003cp\u003eA: Field wiring connects through a dedicated KS9 cable interface designed for direct routing to external interface terminal boards.\u003c\/p\u003e\n\u003cp\u003eQ: How fast does the input circuitry process status changes from field contacts?\u003c\/p\u003e\n\u003cp\u003eA: The module executes digital signal conditioning with a maximum input response time of 8 ms for status inputs.\u003c\/p\u003e\n\u003cp\u003eQ: Does the module support pushbutton input pulse detection functions?\u003c\/p\u003e\n\u003cp\u003eA: No, the module handles standard contact and DC voltage status inputs and does not support dedicated pushbutton pulse logic.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eDisconnect external power sources and verify field loop de-energization prior to inserting or removing the module from the system subrack.\u003c\/p\u003e\n\u003cp\u003eWhen routing dedicated KS9 cables from field terminal blocks, maintain physical separation from high-voltage AC power lines and heavy inductive motor circuits to prevent electromagnetic interference. Firmly tighten cable connector latch screws to secure low-resistance grounding across the shield housing.\u003c\/p\u003e\n\u003cp\u003eVerify that single-point cabinet grounding guidelines are strictly maintained across all minus-side common groupings to prevent ground loops from affecting digital input threshold levels.\u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":67584272793699,"sku":"ADV169","price":360.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/907..jpg?v=1790557770","url":"https:\/\/www.autocontrolglobal.com\/products\/adv169-p00-yokogawa-centum-vp-digital-input-module","provider":"AutoControl Global","version":"1.0","type":"link"}