{"product_id":"adv551-p50-d5s00-yokogawa-digital-output-module","title":"ADV551-P50\/D5S00 Yokogawa Digital Output Module","description":"\u003ch2\u003eYokogawa ADV551-P50\/D5S00 Digital Output Module\u003c\/h2\u003e\n\u003cp\u003eConfigured for discrete field device actuation in CENTUM VP platforms, the \u003cstrong\u003eYokogawa ADV551-P50\/D5S00\u003c\/strong\u003e (\u003cstrong\u003eADV551\u003c\/strong\u003e Digital Output Module) provides direct physical\/electrical execution. This 32-channel current-sink unit directly controls 24 VDC solenoid valves, indicator lamps, and interlock relay coils across distributed process control networks. The module executes static status output, one-shot pulse output, and time-proportioning output modes while delivering galvanic isolation to decouple system backplane electronics from field-side voltage transients.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eSuffix \/ Option Code\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDesignation\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eTechnical Description\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eADV551\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBase Model\u003c\/td\u003e\n\u003ctd\u003eDigital Output Module (32-channel, 24 VDC, isolated)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e-P\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePushbutton Function\u003c\/td\u003e\n\u003ctd\u003eWith pushbutton input function\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e5\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStatus Display \/ Protection\u003c\/td\u003e\n\u003ctd\u003eWithout status display; with no explosion protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e0\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSpecification\u003c\/td\u003e\n\u003ctd\u003eBasic type\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\/D5S00\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTerminal Block Option\u003c\/td\u003e\n\u003ctd\u003eWith Pressure Clamp Terminal Block for Digital Output (Model ATD5S-00)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eADV551-P50\/D5S00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOrigin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.3 kg net (2.0 kg shipping)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStandard CENTUM I\/O module footprint\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-20 to 70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e700 mA max at 5 VDC (backplane), 60 mA max at 24 VDC (external supply)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eChannel Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e32 digital outputs (grouped 16 channels per common)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Circuit Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCurrent sink (NPN transistor)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Output Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 VDC (operating range 20.4 to 26.4 VDC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Load Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 mA per channel at 26.4 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOFF-State Leakage Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;= 0.1 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eON-State Voltage Drop\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;= 2 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIsolation Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2000 VAC for 1 minute (signal-to-system), 500 VAC (channel group-to-group)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Response Time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;= 3 ms (static status output), \u0026lt;= 10 ms (mixed status\/pulse)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConformal Coating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eISA Standard G3 class\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eChannel-to-Channel Isolation \u0026amp; DCS Signal Integrity\u003c\/h3\u003e\n\u003cp\u003eThe hardware relies on photoelectric isolation barriers rated at 2000 VAC between field output terminals and system logic, with 500 VAC isolation between 16-channel common groups. This design mitigates ground loops and prevents electrical noise propagation in high-density process I\/O racks. Configured channels support one-shot pulse outputs with programmable durations from 8 ms to 7200 s at an 8 ms resolution, alongside time-proportioning output algorithms. Integrated ISA Standard G3 conformal coating protects active copper traces from sulfurous and chlorine-driven corrosive gases in process environments.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the module support hot-swapping during active system operation?\u003c\/p\u003e\n\u003cp\u003eA: Yes, the unit supports live hot-swapping inside the I\/O nest. Maintenance personnel must ensure that external 24 VDC field load power remains properly fused and grounded to avoid inductive surges when unseating module backplane connectors.\u003c\/p\u003e\n\u003cp\u003eQ: What output functions can be assigned to the individual output channels?\u003c\/p\u003e\n\u003cp\u003eA: Output channels can be configured for static ON\/OFF status output, one-shot pulse width output, or time-proportioning ON\/OFF output. These modes are set through the CENTUM system software configuration environment.\u003c\/p\u003e\n\u003cp\u003eQ: How is field wiring terminated on the \/D5S00 variant?\u003c\/p\u003e\n\u003cp\u003eA: The \/D5S00 option includes an integrated ATD5S-00 pressure clamp terminal block mounted on the front panel. Signal wires terminate directly via screw-clamp terminals without requiring external interface cables or MIL connectors.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eMount the module firmly into an available slot within the I\/O nest and secure the ATD5S-00 pressure clamp terminal block using the front locking screws. Verify that external 24 VDC loop power to field actuators is delivered from a regulated power supply operating within 20.4 to 26.4 VDC.\u003c\/p\u003e\n\u003cp\u003eStrip field conductors to 6 mm and secure them into the pressure clamp terminals. Route field output cabling in separate, grounded wireways positioned at least 300 mm away from AC power lines to avoid cross-talk and electromagnetic interference. Connect cable shield drain wires to the cabinet functional earth rail using dedicated grounding clamps, maintaining a single-point grounding configuration across the cabinet.\u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":46226720260195,"sku":"ADV551-P50\/D5S00","price":360.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/346._345e3409-ec18-4aa0-93a9-362580707dea.jpg?v=1790061052","url":"https:\/\/www.autocontrolglobal.com\/products\/adv551-p50-d5s00-yokogawa-digital-output-module","provider":"AutoControl Global","version":"1.0","type":"link"}