{"product_id":"ai830-by-abb-3bse008518r1-ac800m-analog-input-module","title":"AI830 by ABB | 3BSE008518R1 AC800M Analog Input Module","description":"\u003ch2\u003eABB AI830 Analog Input Unit\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eABB AI830\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eAI830\u003c\/strong\u003e Analog Input Unit, operates as a dedicated hardware component for RTD and resistance signal acquisition within AC 800M control networks.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAI830 (Product ID: 3BSE008518R1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOrigin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSweden\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.08 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e52.5 mm x 52.5 mm x 21.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStandard industrial environment limits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOperating voltage range of 10-30 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Channels\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8 channels (RTD \/ Resistance)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupported Sensors\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePt100, Ni100\/120, Cu10, R-type resistance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12-bit analog-to-digital conversion\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Isolation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnvironmental Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTermination Units\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTU810, TU812, TU814, TU830\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Bus Communication and Deterministic Networks\u003c\/h3\u003e\n\u003cp\u003eThe module establishes connection with the AC 800M controller backplane interface, enabling high-density signal conversion of low-level analog inputs into digital arrays. This interaction adheres to deterministic network schedules over Profinet or EtherNet\/IP links, avoiding signal latency. The hardware architecture balances I\/O density scaling against power allocation parameters, verifying firmware flash compatibility profiles with host processor slots to prevent data bus collisions during multi-channel execution.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can the AI830 module be hot-swapped while the AC 800M backplane is energized?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA:\u003c\/strong\u003e Yes, when mounted on compatible termination units like the TU810 or TU812, the module supports physical removal and replacement without interrupting power to adjacent I\/O modules on the same cluster bus.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does the 12-bit analog-to-digital converter support mixed sensor configurations concurrently?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA:\u003c\/strong\u003e The software parameters permit diverse configurations per channel, enabling a single module to process separate Pt100, Ni100, and standard resistance inputs on independent terminal lines.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the electrical lifecycle replacement path for this hardware?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA:\u003c\/strong\u003e The AI830 is succeeded by the AI830A module, which matches the form factor and electrical termination parameters for direct retrofitting into existing TU810 base configurations.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eAlign the module with the guide pins of the matching termination unit (TU810, TU812, TU814, or TU830) and press firmly until the mechanical locking mechanism engages.\u003c\/li\u003e\n\u003cli\u003eConnect all RTD and resistance loop lines using shielded twisted-pair cables to mitigate external high-frequency electromagnetic noise.\u003c\/li\u003e\n\u003cli\u003eTerminate the drain wire of the sensor shields strictly at the cabinet earth ground bar, keeping the sensor side isolated to prevent ground loop currents.\u003c\/li\u003e\n\u003cli\u003eEnsure physical separation between the 10-30 V DC power supply lines and high-voltage AC source cables within the wire ducts to avoid inductive cross-talk.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":43865698238563,"sku":"AI830 3BSE008518R1","price":676.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/127.2_f1d5f86e-0971-4ac7-8751-17210764843b.jpg?v=1764581276","url":"https:\/\/www.autocontrolglobal.com\/products\/ai830-by-abb-3bse008518r1-ac800m-analog-input-module","provider":"AutoControl Global","version":"1.0","type":"link"}