AIP502-S1 Yokogawa CENTUM CS V-Net Coupler Module
Manufacturer: Yokogawa
-
Part Number: AIP502 S1
Condition:New with Original Package
Product Type: Communication Modules
-
Country of Origin: Japan
Payment:T/T, Western Union
Shipping port: Xiamen
Warranty: 12 months
Yokogawa AIP502-S1 V-Net Coupler Module
Configured for real-time control signal coupling across Yokogawa CENTUM CS and CENTUM VP platforms, the Yokogawa AIP502-S1 (AIP502 V-Net Coupler Module) provides direct physical/electrical execution.
Hardware Specifications
| Parameter | Specification |
|---|---|
| Model | AIP502-S1 |
| Brand | Yokogawa |
| Origin | USA |
| Weight | 0.5 kg |
| Dimensions | 22 x 124 x 126 mm |
| Operating Temp | 0 to 50 deg C |
| Power Consumption | Powered via backplane bus |
| Product Type | V-Net Coupler Module |
| Communication Network | Yokogawa V-Net |
| Dielectric Strength | 1500 VAC for 1 minute between control circuit and ground |
| Insulation Resistance | Minimum 20 M-ohm at 500 VDC |
| Relative Humidity | 10% to 90% RH, non-condensing |
Process Control & DCS Backplane Dynamics
The AIP502-S1 coordinates high-speed deterministic token-passing communication over the proprietary Yokogawa V-Net control network. To support synchronized control loops, the module executes point-to-point data transmission between field control stations and human interface units. Channel-to-channel isolation hardware mitigates electrical noise and eliminates ground loop current paths across cabinet racks. The onboard signal coupling transformer delivers robust galvanic isolation rated at 1500 VAC, protecting internal system logic gates from high-voltage field transients and power supply surges.
Frequently Asked Questions
Q: What is the dielectric isolation rating between the control circuits and ground for the AIP502-S1?
A: The module features a built-in dielectric isolation barrier rated for 1500 VAC tested for 1 minute between control circuitry and system ground, ensuring signal isolation across node enclosures.
Q: How is primary operational power provided to the AIP502-S1 module?
A: The module draws its required operating current directly from the system rack backplane bus when seated into a designated Field Control Unit slot, eliminating external terminal power wiring.
Q: What steps should be taken if replacing a discontinued AIP502-S1 in an operational rack?
A: Ensure that the host Field Control Unit power supply is isolated or operated under compliant hot-swap maintenance procedures before card extraction to avoid backplane communication bus corruption.
Field Installation Guidelines
Verify that system power is deactivated or that authorized redundant maintenance protocols are engaged prior to card installation. Insert the AIP502-S1 module into its designated rack slot by aligning its PCB edges with the slot guides, then push firmly until the rear connector seats into the backplane socket. Secure the top and bottom retaining screws to establish an active chassis ground path. Route all V-Net network cabling through designated cable channels, maintaining physical isolation from high-voltage AC lines, and clamp all cable shields directly to the cabinet functional earth (FE) bus bar.