{"product_id":"altivar-process-variable-speed-drive-schneider-atv630d37n4","title":"Altivar Process Variable Speed Drive | Schneider ATV630D37N4","description":"\u003ch2\u003eSchneider Electric ATV630D37N4 Altivar Process ATV600 Variable Speed Drive\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eATV630D37N4\u003c\/strong\u003e is a three-phase variable speed drive (VSD) in the Schneider Electric Altivar Process ATV600 series. It regulates the speed and torque of asynchronous and synchronous AC motors from a 380-480 V AC supply, rated for 37 kW (50 HP) in normal-duty service and 30 kW (40 HP) in heavy-duty service. Built-in Ethernet, Modbus TCP\/IP and Modbus serial interfaces, an integrated EMC filter, and Safe Torque Off (STO) at SIL 3 support process and utility motor control.\u003c\/p\u003e\n\u003ch3\u003eDuty Ratings and Motor Control\u003c\/h3\u003e\n\u003cp\u003eUnder normal-duty operation, the \u003cstrong\u003eATV630D37N4\u003c\/strong\u003e delivers 74.5 A continuous output current and up to 82 A transient current for 60 s. Under heavy-duty conditions, continuous output current is 61.5 A with motor ratingsderated to 30 kW (40 HP).\u003c\/p\u003e\n\u003cp\u003eThe drive outputs 0.1-500 Hz at a nominal switching frequency of 4 kHz to drive asynchronous and synchronous motors. Verifying continuous and peak load currents against normal- or heavy-duty limits prevents thermal overload during startup or variable torque swings.\u003c\/p\u003e\n\u003ch3\u003eCommunications, Safety, and Installation\u003c\/h3\u003e\n\u003cp\u003eIntegrated Ethernet supports Modbus TCP\/IP alongside Modbus serial communication for PLC and SCADA integration. An integrated EMC filter helps limit conducted electromagnetic interference on motor and supply lines.\u003c\/p\u003e\n\u003cp\u003eThe drive incorporates a Safe Torque Off (STO) safety function rated to SIL 3 to remove torque-generating energy without cutting main power to the unit. It uses forced convection cooling, mounts on a wall, and carries IP21 and UL Type 1 enclosure ratings.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eATV630D37N4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Series\u003c\/td\u003e\n\u003ctd\u003eAltivar Process ATV600\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eVariable Speed Drive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrive Model\u003c\/td\u003e\n\u003ctd\u003eATV630\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e380-480 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Phases\u003c\/td\u003e\n\u003ctd\u003e3-phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply Frequency\u003c\/td\u003e\n\u003ctd\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNormal-Duty Motor Power\u003c\/td\u003e\n\u003ctd\u003e37 kW (50 HP)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeavy-Duty Motor Power\u003c\/td\u003e\n\u003ctd\u003e30 kW (40 HP)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNormal-Duty Output Current\u003c\/td\u003e\n\u003ctd\u003e74.5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeavy-Duty Output Current\u003c\/td\u003e\n\u003ctd\u003e61.5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Transient Current\u003c\/td\u003e\n\u003ctd\u003e82 A \/ 60 s (Normal Duty)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Frequency\u003c\/td\u003e\n\u003ctd\u003e0.1-500 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Switching Frequency\u003c\/td\u003e\n\u003ctd\u003e4 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor Compatibility\u003c\/td\u003e\n\u003ctd\u003eAsynchronous and synchronous motors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Protocols\u003c\/td\u003e\n\u003ctd\u003eModbus TCP\/IP, Modbus Serial\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork Interface\u003c\/td\u003e\n\u003ctd\u003eIntegrated Ethernet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEMC Filter\u003c\/td\u003e\n\u003ctd\u003eIntegrated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Function\u003c\/td\u003e\n\u003ctd\u003eSafe Torque Off (STO)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Integrity Level\u003c\/td\u003e\n\u003ctd\u003eSIL 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling Method\u003c\/td\u003e\n\u003ctd\u003eForced convection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eWall mounting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Rating\u003c\/td\u003e\n\u003ctd\u003eIP21\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure Rating\u003c\/td\u003e\n\u003ctd\u003eUL Type 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What is the difference between normal-duty and heavy-duty ratings on the Schneider Electric ATV630D37N4? A: Normal-duty operation supports 37 kW (50 HP) at 74.5 A continuous output current (82 A for 60 s transient), whereas heavy-duty operation is rated for 30 kW (40 HP) at 61.5 A continuous output current. Select the rating that matches the load profile and overload margin required by the driven motor.\u003c\/p\u003e\n\u003cp\u003eQ: What motor types and safety functions are supported by the ATV630D37N4? A: It controls asynchronous and synchronous AC motors across 0.1-500 Hz and provides a built-in Safe Torque Off (STO) function rated to SIL 3.\u003c\/p\u003e\n\u003cp\u003eQ: How does the ATV630D37N4 connect to industrial networks? A: It features integrated Ethernet with Modbus TCP\/IP and Modbus serial communication.\u003c\/p\u003e","brand":"Schneider","offers":[{"title":"Default Title","offer_id":67957023572067,"sku":"ATV630D37N4","price":260.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/328._d75ee320-b90b-4e05-894c-49831ea35525.jpg?v=1795059940","url":"https:\/\/www.autocontrolglobal.com\/products\/altivar-process-variable-speed-drive-schneider-atv630d37n4","provider":"AutoControl Global","version":"1.0","type":"link"}