{"product_id":"amc80-yokogawa-16-bit-a-d-d-a-process-control-board","title":"AMC80 Yokogawa 16-Bit A\/D D\/A Process Control Board","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe Yokogawa AMC80 (Model Reference: AMC80\/ZCT) operates as a high-density, multipoint analog input\/output module engineered for precise data acquisition and actuator manipulation within critical process control architectures. This multi-channel hardware asset consolidates both input and output loops onto a unified board, utilizing dedicated 16-bit analog-to-digital (A\/D) and digital-to-analog (D\/A) converters. Control engineers deploy this versatile module within Yokogawa CENTUM CS and CENTUM VP Distributed Control Systems (DCS) to manage dense clusters of field instrumentation, including control valves, variable speed drives, temperature transmitters, and pressure sensors.\u003c\/p\u003e\n\u003ch3\u003ePart Number Breakdown\u003c\/h3\u003e\n\u003cp\u003eThe AMC80 series uses a structured suffix matrix to establish the mechanical mounting frame, channel densities, and specific grounding configurations:\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eSuffix \/ Attribute\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSelection Code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eArchitectural Meaning\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBase Model\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAMC80\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCore Multipoint Analog Input\/Output Module Platform\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eGrounding Layout\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\/ZCT\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eZero-phase Current Transformer grounding interface \/ enhanced shielding\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eChannel Variant 1\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFactory Specified\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8-Channel Input \/ 8-Channel Output density configuration\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eChannel Variant 2\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFactory Specified\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e16-Channel Input \/ 16-Channel Output density configuration\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eChannel Variant 3\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFactory Specified\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e32-Channel Input high-density monitoring profile\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Value\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eYokogawa\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel Code\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAMC80\/ZCT\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModule Classification\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMultipoint Analog Input \/ Output Processor Module\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDCS System Compatibility\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eYokogawa CENTUM CS and CENTUM VP Control Networks\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eAnalog Input Capacity Options\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8, 16, or 32 distinct channels (hardware configuration dependent)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eAnalog Output Capacity Options\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8 or 16 distinct channels (hardware configuration dependent)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eData Processing Resolution\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e16-bit A\/D (Inputs) and 16-bit D\/A (Outputs) converter tracks\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSignal Formats Managed\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4-20 mA current loops, 0-10 VDC standard voltage paths\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMeasurement Accuracy\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePlus\/minus 0.1% of full scale span under typical loads\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCircuit Isolation Barrier\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFull channel-to-channel and channel-to-system galvanic isolation\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eHardware Noise Defense\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHigh-attenuation electromagnetic interference (EMI) filtering\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSystem Diagnostics Display\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eReal-time integrated LEDs for module health and active loop status\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eIngress Protection Rating\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIP20\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePhysical Outer Dimensions\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e260 mm x 180 mm x 60 mm (W x H x D)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNet Structural Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.3 kg (0.66 lbs)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCabinet Installation Method\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eRack-mounted directly into standard Yokogawa DCS backplanes\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 to +55 degrees Celsius\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eStorage Temperature Boundaries\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-20 to +70 degrees Celsius\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePermissible Ambient Humidity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5% to 95% relative humidity (non-condensing)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eQuality Procurement Status\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUsed, fully tested, and professionally cleaned\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003ch3\u003eIntegrated A\/D and D\/A Converters Drastically Cut Backplane Traffic\u003c\/h3\u003e\n\u003cp\u003eThe AMC80 minimizes internal bus bottlenecks by performing all analog-to-digital and digital-to-analog mathematical conversions directly on the local module processor. This onboard data processing unburdens the primary DCS backplane from executing raw signal arithmetic. Because the module transmits highly compressed, clean binary data packets over the proprietary Yokogawa bus, the system maintains fast update scan rates across the rest of the control chassis.\u003c\/p\u003e\n\u003ch3\u003eDual-Layer Isolation Blockades High-Voltage System Disturbances\u003c\/h3\u003e\n\u003cp\u003eIndustrial field wiring lines often cross paths with high-current motor starters and heavy switchgear, risking dangerous voltage injection. The AMC80 features dual-layer galvanic isolation barriers that separate individual channels from each other, while concurrently isolating the field terminal loops from the internal system logic board. This electrical isolation prevents localized field short-circuits or lightning surges from traveling up the signal wire and destroying the central DCS controller backplane.\u003c\/p\u003e\n\u003ch3\u003eCombined I\/O Architecture Shrinks Required Panel Enclosure Footprints\u003c\/h3\u003e\n\u003cp\u003eTraditional distributed control systems require separate, dedicated rack slots for analog input cards and analog output cards. The AMC80 merges high-density input tracking and active output driving onto a single rack-mounted board footprint weighing just 0.3 kg. This consolidation allows control panel builders to reclaim up to 50% of the rack slot space inside marshalling enclosures, lowering structural hardware costs and simplifying wire bundle routing.\u003c\/p\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eWhat exact testing protocol did this used AMC80 module undergo before approval?\u003c\/p\u003e\n\u003cp\u003eOur engineering lab subjects every used Yokogawa AMC80 module to rigorous automated diagnostics. We inject full-range 4-20 mA and 0-10 VDC test patterns into all input channels to confirm 16-bit A\/D conversion accuracy, loop-verify the D\/A output stages under maximum load, and stress-test the isolation barriers. The card is then thoroughly cleaned of industrial residue before being sealed in anti-static shipping materials.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan a technician mix voltage and current loop field signals on the same AMC80 card?\u003c\/p\u003e\n\u003cp\u003eYes. The internal hardware multiplexer and software options allow you to map out specific channels for standard 4-20 mA current loops (like flow meters) while dedicating other terminals to 0-10 VDC signals (like variable speed drive commands). Refer to your CENTUM engineering workspace manual to configure individual software channel attributes correctly.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDoes this module support hot-swapping if a facility deploys dual-redundant configurations?\u003c\/p\u003e\n\u003cp\u003eYes. When you configure two AMC80 modules in a dual-redundant backplane slot arrangement, the Yokogawa DCS maintains active process control through the secondary card if the primary card encounters a fault. This layout allows maintenance personnel to slide out the problematic module and insert the replacement card without powering down the control rack or disrupting live production loops.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":43886257078371,"sku":"AMC80\/ZCT","price":360.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/338_288a761d-98d0-46e6-8ea0-022b350b4fa6.jpg?v=1765522422","url":"https:\/\/www.autocontrolglobal.com\/products\/amc80-yokogawa-16-bit-a-d-d-a-process-control-board","provider":"AutoControl Global","version":"1.0","type":"link"}