{"product_id":"amm22m-yokogawa-analog-input-module-new-original-stock","title":"AMM22M Yokogawa Analog Input Module | New \u0026 Original Stock","description":"\u003ch2\u003eYokogawa AMM22M Analog Input Module\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eYokogawa AMM22M\u003c\/strong\u003e serves as the primary \u003cstrong\u003eAMM22M\u003c\/strong\u003e Analog Input Module utilized to execute multi-channel current signal acquisition across CENTUM VP, ProSafe-RS, and FIO platforms. The hardware acts as a high-density processing interface that actively acquires raw analog measurements from interconnected transmitters, converting physical currents and voltages into accurate digitized values for upstream distributed control networks.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"2\"\u003eModel\u003c\/td\u003e\n\u003ctd data-row=\"2\"\u003eAMM22M\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"3\"\u003eBrand\u003c\/td\u003e\n\u003ctd data-row=\"3\"\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"4\"\u003eOrigin\u003c\/td\u003e\n\u003ctd data-row=\"4\"\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"5\"\u003eWeight\u003c\/td\u003e\n\u003ctd data-row=\"5\"\u003e0.4 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"6\"\u003eDimensions\u003c\/td\u003e\n\u003ctd data-row=\"6\"\u003e107.5 x 32.8 x 130 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"7\"\u003eOperating Temp\u003c\/td\u003e\n\u003ctd data-row=\"7\"\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"8\"\u003ePower Consumption\u003c\/td\u003e\n\u003ctd data-row=\"8\"\u003e24 V DC via FIO base unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"9\"\u003eChannels\u003c\/td\u003e\n\u003ctd data-row=\"9\"\u003e16 analog input channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"10\"\u003eSignal Types\u003c\/td\u003e\n\u003ctd data-row=\"10\"\u003e4-20 mA DC (current), 1-5 V DC (voltage)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"11\"\u003eResolution\u003c\/td\u003e\n\u003ctd data-row=\"11\"\u003e12-16 bit (configuration dependent)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"12\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd data-row=\"12\"\u003e+\/-0.1% of span\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"13\"\u003eInput Impedance\u003c\/td\u003e\n\u003ctd data-row=\"13\"\u003e250 Ohm (for current inputs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"14\"\u003eHumidity\u003c\/td\u003e\n\u003ctd data-row=\"14\"\u003e5-95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eProcess Control \u0026amp; DCS Instrumentation Properties\u003c\/h3\u003e\n\u003cp\u003eThis processing card integrates robust channel-to-channel isolation parameters alongside system-side galvanic separation to shield internal microprocessor logic from high-voltage field transients. The module executes parallel analog conversion routines with integrated diagnostics that constantly supervise the loops for open circuit states, localized short circuits, and signal-range monitoring limits. When embedded within a redundant bus layout, it performs rapid data acquisition synchronizations to ensure error-free failover handshakes without disrupting the overarching process variable arrays.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How does the hardware respond to an online hot-swap maintenance procedure?\u003c\/p\u003e\n\u003cp\u003eA: The physical backplane pin geometry is designed to isolate signal lines sequentially. The card permits hot-swap extraction and insertion while the FIO base unit remains active, preventing power dips or data degradation across adjacent operating I\/O nodes.\u003c\/p\u003e\n\u003cp\u003eQ: What mechanisms handle the selection between current inputs and voltage inputs?\u003c\/p\u003e\n\u003cp\u003eA: Signal conditioning configuration dictates the functional resolution and input scaling. The input impedance behaves as a nominal 250 Ohm load when current mode is active, dropping voltage drops accurately across internal precision shunts.\u003c\/p\u003e\n\u003cp\u003eQ: Can this module operate within a safety-instrumented architecture?\u003c\/p\u003e\n\u003cp\u003eA: Yes, when deployed alongside the ProSafe-RS platform, the module conforms to safety integrity level (SIL) certifications, rendering its internal diagnostics capable of handling safety-critical loop monitoring duties.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eModule Seating\u003c\/strong\u003e: Guide the module vertically into the allocated FIO base unit slot, applying even force until the integrated mechanical locking clips engage the chassis frame completely.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShielding Ground Base\u003c\/strong\u003e: Terminate all instrument twisted-pair shielding exclusively at the marshalling panel's central ground bar. Do not ground both sides of the cable shield to prevent circulating ground loop noise from corrupting the 12-16 bit conversion registers.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConductor Separation\u003c\/strong\u003e: Route all 4-20 mA DC and 1-5 V DC lines away from high-power inductive circuits or three-phase motor lines by a minimum distance of 50 mm inside the cable trays.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental Enforcement\u003c\/strong\u003e: Ensure the local cabinet housing maintains proper ventilation profiles so that the local temperature tracking does not exceed the upper 60 deg C threshold.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":44215936974947,"sku":"AMM22M","price":240.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/267_58bef88c-cc8a-4b16-adca-75add4411166.jpg?v=1779786679","url":"https:\/\/www.autocontrolglobal.com\/products\/amm22m-yokogawa-analog-input-module-new-original-stock","provider":"AutoControl Global","version":"1.0","type":"link"}