{"product_id":"amt16m-yokogawa-16-channel-voltage-input-multiplexer","title":"AMT16M Yokogawa 16-Channel Voltage Input Multiplexer","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eYokogawa AMT16M\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efunctions as a high-density voltage input multiplexer, specifically engineered to streamline data acquisition in Distributed Control Systems (DCS) and Programmable Logic Controllers (PLC). This module aggregates analog signals from up to\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e16 independent channels\u003c\/strong\u003e, converting 0 to 10 V DC field inputs into actionable digital data. By utilizing\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eModbus RTU\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ecommunication, the AMT16M integrates seamlessly into existing industrial networks, providing high-precision monitoring for process variables. Its ultra-low power consumption and ruggedized design make it a primary choice for engineers managing large-scale sensor arrays in demanding industrial environments.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003eThe AMT16M delivers laboratory-grade accuracy within a hardened industrial form factor:\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAMT16M\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVoltage Input Multiplexer Module\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eChannel Count\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e16 Input Channels\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Signal Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 to 10 V DC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e±0.01% + ±1 digit\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCommunication Protocol\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eModbus RTU\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eStandard 35mm DIN Rail\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e≤ 1 W\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e–20°C to +70°C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eEnclosure Rating\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIP20\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e500 g\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e100% Brand New and Original\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Density Signal Integration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 16-channel architecture allows the AMT16M to replace multiple single-channel units. This consolidation reduces the physical footprint within control cabinets and simplifies the wiring topology for complex sensor networks.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSuperior Measurement Precision:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWith an accuracy rating of ±0.01%, the module captures minute fluctuations in voltage signals. This precision proves vital in applications requiring strict process tolerances, such as chemical dosing or high-end laboratory monitoring.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModbus RTU Universal Compatibility:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module utilizes the industry-standard Modbus RTU protocol. This ensures that the AMT16M communicates effortlessly with almost any modern DCS, PLC, or SCADA system without requiring proprietary drivers or complex translation gateways.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eExtreme Thermal Stability:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEngineered to operate from –20°C to +70°C, the AMT16M maintains its calibration and data integrity even in unconditioned outdoor panels or high-heat manufacturing zones.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEnergy-Efficient Design:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eConsuming less than 1W of power, the module minimizes the thermal load within enclosed panels. This prevents heat buildup, thereby extending the lifespan of adjacent electronic components in high-density installations.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: Can the AMT16M handle 4-20mA current signals?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA1:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe AMT16M natively accepts\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e0 to 10 V DC voltage signals\u003c\/strong\u003e. To monitor 4-20mA current loops, you must install a high-precision shunt resistor (typically 250 ohms) across the input terminals to convert the current into a 1-5V voltage signal compatible with the module's range.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: How does the multiplexing feature impact sampling speed?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA2:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe AMT16M utilizes high-speed internal switching to scan all 16 channels. While multiplexing occurs sequentially, the internal processing speed ensures that data for all channels remains current for standard industrial process monitoring and Modbus polling cycles.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: Is any specialized software required for Modbus configuration?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA3:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eNo proprietary software is necessary. You can configure the communication parameters (Baud rate, Parity, Slave ID) using standard Modbus configuration tools or directly through your PLC\/DCS programming environment.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ4: How do I verify the \"Brand New\" status of the unit?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA4:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEvery AMT16M we supply is\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New and Original\u003c\/strong\u003e. Each unit ships in its original Yokogawa factory packaging, complete with the manufacturer's serial numbers and quality inspection documentation for full traceability.\u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":43802099122275,"sku":"AMT16M","price":360.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/143_057a26e4-fe0b-4886-a3be-409d251da72e.jpg?v=1761813175","url":"https:\/\/www.autocontrolglobal.com\/products\/amt16m-yokogawa-16-channel-voltage-input-multiplexer","provider":"AutoControl Global","version":"1.0","type":"link"}