{"product_id":"analog-i-o-processor-board-ge-fanuc-is200aepbh1bb-mark-vie","title":"Analog I\/O Processor Board GE Fanuc IS200AEPBH1BB Mark VIe","description":"\u003ch2\u003eGE Fanuc IS200AEPBH1BB Analog I\/O Processor Board\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eGE Fanuc IS200AEPBH1BB\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eIS200AEPBH1B\u003c\/strong\u003e Analog I\/O Processor Board (AEPB), operates as a dedicated hardware component for deterministic analog-to-digital conversion and fault-tolerant transmission within Mark VI and Mark VIe turbine control platforms.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eVariant Classification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eIS200AEPBH1B\u003c\/td\u003e\n\u003ctd\u003eBase module design\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIS200AEPBH1BB\u003c\/td\u003e\n\u003ctd\u003eRevision B: Includes enhanced conformal coating and improved hardware reliability\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIS200AEPBH1BB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE Fanuc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eChina\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.67 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e12.0 cm × 10.0 cm × 5.0 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-40 deg C to 85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e0.6 A at 5 VDC, plus auxiliary 24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e16-bit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e+\/- 0.1 to 0.2 percent of span\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eIndustrial Control \u0026amp; Processing Characteristics\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eGE Fanuc IS200AEPBH1BB\u003c\/strong\u003e incorporates internal logic to support backplane bus communication velocity metrics required for deterministic Mark VIe networks. The module architecture is designed for I\/O density scaling, facilitating the integration of 8 software-selectable isolated channels within the turbine control cabinet. Firmware flash compatibility ensures that the AEPB can receive logic updates through the system controller, maintaining synchronization across the TMR voting architecture. The circuitry implements channel-to-channel isolation to prevent propagation of signal faults, maintaining data integrity during high-speed analog loop processing.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the IS200AEPBH1BB support TMR voting at the module level?\u003c\/p\u003e\n\u003cp\u003eA: The module is designed to function within a Triple Modular Redundancy (TMR) architecture, allowing the system controller to compare inputs across three parallel modules to ensure fault-tolerant signal processing.\u003c\/p\u003e\n\u003cp\u003eQ: How does the module respond to a loss of communication with the controller?\u003c\/p\u003e\n\u003cp\u003eA: The AEPB provides configurable fail-safe output states; the module can be programmed to either hold the last known good value or transition to a pre-defined safe state upon detection of a communication loss.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eBefore installing the \u003cstrong\u003eGE Fanuc IS200AEPBH1BB\u003c\/strong\u003e, ensure the rack is de-energized to prevent electrical damage to the 500 VDC isolation barriers. Align the module carefully with the backplane connectors to prevent pin bending. All analog signal shields should be terminated at the cabinet common ground point to suppress noise and improve electromagnetic compatibility. Given the wide operating temperature range, ensure that the cabinet ventilation remains unobstructed to facilitate adequate thermal dissipation during continuous operation.\u003c\/p\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":44304609443939,"sku":"IS200AEPBH1BB","price":175.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/81.1_e53a6d35-c739-4e21-af1c-074f1929745a.jpg?v=1782811289","url":"https:\/\/www.autocontrolglobal.com\/products\/analog-i-o-processor-board-ge-fanuc-is200aepbh1bb-mark-vie","provider":"AutoControl Global","version":"1.0","type":"link"}