{"product_id":"analog-input-module-ge-ic695alg626-pacsystems-rx3i-hart","title":"Analog Input Module GE IC695ALG626 PACSystems RX3i HART","description":"\u003ch2\u003eGE Fanuc IC695ALG626 PACSystems RX3i Analog Input Module\u003c\/h2\u003e\n\u003cp\u003eConfigured for high-density signal acquisition in PACSystems RX3i platforms, the \u003cstrong\u003eGE Fanuc IC695ALG626-HC\u003c\/strong\u003e (\u003cstrong\u003eIC695ALG626\u003c\/strong\u003e Analog Input Module) provides direct physical\/electrical execution. This non-isolated module interfaces with field transmitters across 16 single-ended or 8 differential input channels, digitizing voltage signals from -10 VDC to +10 VDC and current signals from 0 to 20 mA or 4 to 20 mA via an onboard 24-bit ADC. Incorporating HART Version 5.0 protocol support, the unit processes analog loop values and digital secondary variables directly through the RX3i backplane bus.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIC695ALG626-HC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE Fanuc \/ Emerson\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.45 kg (1.00 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eSingle-slot RX3i footprint\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C (32 to 140 deg F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e600 mA at 3.3 VDC, 450 mA at 5 VDC (7.35 W max dissipation)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannel Configuration\u003c\/td\u003e\n\u003ctd\u003e16 single-ended or 8 differential channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Signal Ranges\u003c\/td\u003e\n\u003ctd\u003eVoltage: +-10 VDC, 0-10 VDC, +-5 VDC, 0-5 VDC, 1-5 VDC; Current: 0-20 mA, 4-20 mA, +-20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e24-bit ADC (converted to 32-bit floating point or 16-bit integer)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtocol Support\u003c\/td\u003e\n\u003ctd\u003eHART Version 5.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOvervoltage \/ Overcurrent\u003c\/td\u003e\n\u003ctd\u003e+-60 VDC continuous max \/ +-28 mA continuous max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Resistance\u003c\/td\u003e\n\u003ctd\u003e\u0026gt;100 kOhm (voltage input), 249 Ohm +-1% (current input)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eDeterministic Backplane \u0026amp; HART Loop Execution\u003c\/h3\u003e\n\u003cp\u003eThe IC695ALG626-HC transfers digitized process variable data directly across the PACSystems RX3i universal backplane bus, enabling deterministic scan performance with user-configurable digital input filtering (8 Hz to 500 Hz). The module manages 4-20 mA HART loop protocol communications without requiring external modems, passing secondary device diagnostics and dynamic variables to the CPU. Software-configurable channel parameters eliminate physical hardware jumpers, while automatic power-up calibration and firmware flash compatibility maintain measurement accuracy and configuration integrity within the RX3i backplane rack.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the IC695ALG626-HC require physical jumper settings for current or voltage channel selection?\u003c\/p\u003e\n\u003cp\u003eA: No, all channel parameters, including voltage\/current input ranges, digital filter settings, and HART communications, are entirely software-configured via Proficy Machine Edition.\u003c\/p\u003e\n\u003cp\u003eQ: What is the open-circuit detection latency for 4-20 mA current loops?\u003c\/p\u003e\n\u003cp\u003eA: The module executes open-circuit detection on 4-20 mA current ranges within a maximum response time of 1 second.\u003c\/p\u003e\n\u003cp\u003eQ: Can HART protocol features be used on voltage input channels?\u003c\/p\u003e\n\u003cp\u003eA: No, HART Version 5.0 digital communication functions strictly on channels configured for the 4-20 mA current loop range.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eTerminal Block Assembly\u003c\/strong\u003e: Use compatible RX3i terminal blocks (IC694TBB032, IC694TBB132, IC694TBS032, or IC694TBS132). Ensure the module is de-energized before latching the terminal block into position.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShield Grounding Practices\u003c\/strong\u003e: Terminate field signal cable shields to the designated ground bar on the RX3i rack baseplate using low-impedance connections. Ground shields at one end only to prevent ground loop interference.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent Loop Resistors\u003c\/strong\u003e: When wiring current loops, observe the 249 Ohm internal precision resistor load. Ensure total loop impedance does not cause thermal derating under maximum ambient operating temperatures.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":44567082336355,"sku":"IC695ALG626-HC","price":120.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/238_ebdac8a8-23a2-4c3b-bd4c-2e20fa588612.jpg?v=1788851937","url":"https:\/\/www.autocontrolglobal.com\/products\/analog-input-module-ge-ic695alg626-pacsystems-rx3i-hart","provider":"AutoControl Global","version":"1.0","type":"link"}