Analog Input Module | Schneider Electric 170BAI03600
Analog Input Module | Schneider Electric 170BAI03600
Analog Input Module | Schneider Electric 170BAI03600
/ 3

Analog Input Module | Schneider Electric 170BAI03600

  • Manufacturer: Schneider

  • Part Number: 170BAI03600

  • Condition:New with Original Package

  • Product Type: Analog Input Modules

  • Country of Origin: USA

  • Payment:T/T, Western Union

  • Shipping port: Xiamen

  • Warranty: 12 months

Schneider Electric 170BAI03600 Modicon Momentum Analog Input Module

Configured for precise analog signal acquisition in Modicon Momentum platforms, the Schneider Electric 170BAI03600 (170BAI03600 Analog Input Module) provides direct physical electrical execution by converting multi-channel field inputs into digital values for controller processing.

Hardware Specifications

Parameter Specification
Model 170BAI03600
Brand Schneider Electric
Origin Consult Factory
Weight 0.284 kg
Dimensions 141.5 x 125 x 47.5 mm
Operating Temp 0 to 60 deg C
Power Consumption Internal backplane powered
Number of Channels 8 differential analog inputs
Input Ranges +/-10 V, +/-5 V, 0 to 20 mA, 4 to 20 mA
Resolution 12-bit (converted to 16-bit signed)
Isolation Channel-to-bus isolation

Backplane Bus Communication and I/O Density Scaling

The module communicates via the high-velocity Modicon Momentum backplane bus, transferring digitized 16-bit signed measurement data directly to central processing registers. Engineers utilize its high I/O density scaling design to capture eight differential analog input channels within a single compact housing. Furthermore, strict deterministic network timing and firmware flash compatibility ensure synchronized data exchanges across distributed industrial nodes without propagation delays.

Frequently Asked Questions

Q: Can the 170BAI03600 be hot-swapped while the Momentum base remains energized?

A: Hot-swapping is restricted while system power and field loops are active, as electrical transients can damage internal analog-to-digital conversion components. Always isolate power prior to module extraction.

Q: How does the unit identify open-circuit faults on active current loops?

A: The internal diagnostic circuit incorporates built-in wire break detection specifically for 4-20 mA input loops, immediately flagging open conditions through status LED indicators and controller registers.

Field Installation Guidelines

Mount the unit securely onto a standard DIN rail or Momentum baseplate, verifying that mechanical locking latches engage completely. Route low-voltage analog signal cables separately from high-voltage power conduits to suppress electromagnetic induction and measurement noise. Terminate all cable shields securely to protective earth to preserve signal integrity across the analog loops.