Analog Input Module | Schneider Electric 170BAI03600
Manufacturer: Schneider
-
Part Number: 170BAI03600
Condition:New with Original Package
Product Type: Analog Input Modules
-
Country of Origin: USA
Payment:T/T, Western Union
Shipping port: Xiamen
Warranty: 12 months
Schneider Electric 170BAI03600 Modicon Momentum Analog Input Module
Configured for precise analog signal acquisition in Modicon Momentum platforms, the Schneider Electric 170BAI03600 (170BAI03600 Analog Input Module) provides direct physical electrical execution by converting multi-channel field inputs into digital values for controller processing.
Hardware Specifications
| Parameter | Specification |
|---|---|
| Model | 170BAI03600 |
| Brand | Schneider Electric |
| Origin | Consult Factory |
| Weight | 0.284 kg |
| Dimensions | 141.5 x 125 x 47.5 mm |
| Operating Temp | 0 to 60 deg C |
| Power Consumption | Internal backplane powered |
| Number of Channels | 8 differential analog inputs |
| Input Ranges | +/-10 V, +/-5 V, 0 to 20 mA, 4 to 20 mA |
| Resolution | 12-bit (converted to 16-bit signed) |
| Isolation | Channel-to-bus isolation |
Backplane Bus Communication and I/O Density Scaling
The module communicates via the high-velocity Modicon Momentum backplane bus, transferring digitized 16-bit signed measurement data directly to central processing registers. Engineers utilize its high I/O density scaling design to capture eight differential analog input channels within a single compact housing. Furthermore, strict deterministic network timing and firmware flash compatibility ensure synchronized data exchanges across distributed industrial nodes without propagation delays.
Frequently Asked Questions
Q: Can the 170BAI03600 be hot-swapped while the Momentum base remains energized?
A: Hot-swapping is restricted while system power and field loops are active, as electrical transients can damage internal analog-to-digital conversion components. Always isolate power prior to module extraction.
Q: How does the unit identify open-circuit faults on active current loops?
A: The internal diagnostic circuit incorporates built-in wire break detection specifically for 4-20 mA input loops, immediately flagging open conditions through status LED indicators and controller registers.
Field Installation Guidelines
Mount the unit securely onto a standard DIN rail or Momentum baseplate, verifying that mechanical locking latches engage completely. Route low-voltage analog signal cables separately from high-voltage power conduits to suppress electromagnetic induction and measurement noise. Terminate all cable shields securely to protective earth to preserve signal integrity across the analog loops.