{"product_id":"anb10d-410-yokogawa-dual-power-supply-node-interface","title":"ANB10D-410 Yokogawa Dual Power Supply Node Interface","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eYokogawa ANB10D-410\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eserves as a core communication and power hub within the CENTUM VP Distributed Control System (DCS). This\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% brand new\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eoriginal node unit facilitates the high-speed connection between Field Control Stations (FCS) and remote I\/O modules via the ESB bus. By integrating dual-redundant power supplies and communication pathways, the ANB10D-410 ensures that critical process data remains available even during hardware component failures in demanding oil, gas, and power environments.\u003c\/p\u003e\n\u003ch3\u003ePart Number Breakdown: ANB10D\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eSuffix Code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eANB10D\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eESB Bus Node Unit (Dual-Redundant Power Supply)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e-4\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDual-redundant 100-120 V AC Power Supply\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e1\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e19-inch Rack Mountable Type\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e0\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBasic Type (No Explosion Protection)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003eThe ANB10D-410 provides a robust physical and electrical environment for mounting I\/O modules while maintaining deterministic communication across the control network.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eANB10D-410\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCommunication Bus\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eESB Bus (High-speed Interface)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eI\/O Module Slots\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8 Slots for I\/O Modules\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePower Supply\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDual-redundant 100-120 V AC (85-132 V AC range)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eFrequency\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e50\/60 Hz +\/- 3 Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMax 200 VA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e19-inch rack mount\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWithstanding Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1500 V AC between power and ground\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 to 50 °C (32 to 122 °F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e6.0 kg (without I\/O modules)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cp\u003eThe ANB10D-410 optimizes DCS architecture by solving common reliability and scalability bottlenecks:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEliminates Single Points of Failure:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe \"D\" designation signifies a dual-redundant power configuration. If one power supply unit fails, the secondary unit assumes the full load instantly without interrupting the ESB bus communication or I\/O processing.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMaximizes Signal Integrity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eYokogawa engineers the backplane with high-grade shielding to resist electromagnetic interference (EMI). This ensures that analog and digital signals remain accurate when the node resides near high-voltage switchgear or heavy rotating machinery.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eStreamlines Maintenance:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe hot-swappable design of the power supply units allows technicians to replace faulty components while the node unit remains live. This capability significantly reduces Mean Time to Repair (MTTR) and prevents costly process shutdowns.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFlexible Scalability:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 19-inch rack-mountable form factor allows for high-density installation in standard control cabinets. Engineers can daisy-chain multiple ANB10D units to expand I\/O capacity as plant requirements grow.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the ANB10D-410 arrive with the I\/O modules pre-installed?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. The ANB10D-410 provides the infrastructure (slots, power, and bus interface). You must purchase and install the specific I\/O modules required for your process variables separately.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow does the redundancy check work on this unit?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe unit continuously monitors the output voltage of both power supply modules. If one module drops below the rated threshold, the unit triggers a system alarm in the CENTUM VP software while the healthy module maintains seamless operation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan I install this module in a hazardous area?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe \"-410\" suffix indicates the basic type. For applications requiring explosion protection or intrinsically safe barriers, you must verify the specific regional certifications (such as ATEX or FM) and select the corresponding Yokogawa suffix code.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs it necessary to use both power inlets?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWhile the unit functions on a single power source, we strongly recommend connecting each power inlet to independent circuits (e.g., one to mains and one to a UPS) to fully utilize the dual-redundant engineering of the ANB10D-410.\u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":43790754414691,"sku":"ANB10D-410","price":240.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/160_aa8ae7e8-eefd-40e7-aaa0-beea4c023cd2.jpg?v=1761206043","url":"https:\/\/www.autocontrolglobal.com\/products\/anb10d-410-yokogawa-dual-power-supply-node-interface","provider":"AutoControl Global","version":"1.0","type":"link"}