Product Overview
The ABB AO801 (Part Number: 3BSE020514R1) operates as an 8-channel analog output module within the distributed S800 I/O system platform. This core process automation component converts digital commands from AC 800M or System 800xA controllers into standard 0 to 20 mA or 4 to 20 mA current loops. These standard analog signals directly drive field-side equipment, including pneumatic valve positioners, current-to-pressure (I/P) signal converters, and variable speed drive inputs. We supply this industrial module exclusively as a 100% brand new, original factory unit sourced from ABB Sweden, guaranteeing total parameter compliance and long-term hardware reliability in demanding factory environments.
Technical Specifications
| Technical Parameter | Specification Data Value |
| Manufacturer | ABB |
| Model Designation | AO801 |
| Catalog Number | 3BSE020514R1 |
| Channel Type | Analog Output (AO) |
| Number of Channels | 8 analog current outputs |
| Output Signal Range | 0 to 20 mA or 4 to 20 mA |
| Maximum Output Level | 22 mA under internal overload conditions |
| Maximum Load Impedance | Less than or equal to 850 Ohm |
| Digital Resolution | 12-bit binary conversion |
| Isolation Design | Groupwise isolated from ground loop lines |
| Diagnostics System | Front faceplate status LEDs for Fault, Run, Warning |
| Internal Power Draw (5V) | 80 mA from Modulebus |
| Internal Power Draw (24V) | 110 to 150 mA from Modulebus |
| Signal Rise Time Profile | 1 ms (10 percent to 90 percent step change) |
| Maximum Thermal Drift | 100 ppm per degree Celsius |
| Ambient Temperature Limits | 0 to +55 degrees Celsius |
| Storage Temperature Range | -40 to +70 degrees Celsius |
| Physical Enclosure Size | 45 x 102 x 119 mm |
| Net Hardware Weight | 0.24 kg |
| Global HS Customs Code | 853890 |
Engineering Advantages
-
High-Impedance Drive Extends Cable Reach: The AO801 output circuitry drives high-impedance loads up to 850 Ohms. This extra voltage headroom allows field engineers to run longer copper signal cables from centralized control rooms to distant field actuators without suffering signal drop or losing loop power.
-
Fast Response Time Stabilizes Dynamic Loops: A rapid 1 ms signal rise time permits near-instantaneous current adjustments. This high responsiveness ensures excellent control loop stability when driving fast-acting proportional valves or high-speed variable speed drives on critical fluid processing lines.
-
Groupwise Electrical Isolation Blocks Interference: Groupwise electrical isolation decouples the external field-side current loops from the internal digital Modulebus backplane. This structural barrier blocks ground loop offsets, inductive voltage spikes, and high-frequency noise from corrupting the central processor memory assets.
-
Hazardous Area Certification Optimizes Placement: Boasting official ATEX Zone 2 and IECEx compliance, the module operates safely inside volatile industrial processing environments. Plant designers can mount the I/O rack directly inside local field junction boxes, significantly reducing the cost of long field wiring paths.
FAQs
-
Is this specific AO801 module a 100% brand new product?
Yes. We ship this item solely as a 100% brand new, authentic factory-packaged component. It arrives inside original ABB commercial packaging with intact serial numbers and full factory warranty coverage.
-
Does this analog output board feature independent channel-to-channel isolation?
No. The AO801 utilizes a groupwise isolation design rather than individual channel-to-channel isolation. The 8 output channels share a common internal ground line but remain fully isolated as a single cluster from the primary system power and processor backplane.
-
Can I pull and replace this module while the backplane is powered?
Yes. When paired with a compatible S800 Module Termination Unit (MTU), the hardware supports live hot-swap installation. Maintenance technicians can pull a damaged module and insert a brand new replacement unit without isolating power to the main I/O rack or disrupting adjacent processing loops.
-
What component do I need to wire the field devices to this module?
The AO801 requires a separate S800 Module Termination Unit (MTU) to handle physical field wiring and secure the module to the standard DIN-rail. Ensure you select the correct MTU base model that matches your specific terminal connection and redundancy parameters.