{"product_id":"application-processor-interconnect-hub-51401381-100-honeywell","title":"Application Processor Interconnect Hub | 51401381-100 Honeywell","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eHoneywell 51401381-100\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eserves as the primary structural and electrical foundation for Honeywell TDC 3000X Distributed Control Systems (DCS). This brand-new, original 5-slot backpanel functions as an interconnection hub, providing the critical data and power pathways required for Application Processors, Gateways, History Modules, and Universal Stations. By centralizing module communication and power distribution, the 51401381-100 ensures high-speed synchronization across the control network while maintaining a compact footprint for streamlined cabinet organization.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003eThe 51401381-100 utilizes industrial-grade multilayer circuitry to support high-speed data traffic:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eManufacturer:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eHoneywell\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModel Number:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e51401381-100\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCondition:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e100% Brand New, Factory Original\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSystem Type:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eTDC 3000X DCS\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSlot Configuration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e5 High-reliability module slots\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Voltage:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e24 VDC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eData Throughput:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUp to 1 Mbps (inter-module)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e−40 °C to +85 °C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDimensions:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e120 mm × 75 mm × 30 mm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHousing Material:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eVibration-resistant, industrial-grade composite\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEMC Standards:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFully compliant with Honeywell safety and EMI benchmarks\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWeight:\u003c\/strong\u003e\u003cspan\u003e 2.0\u003c\/span\u003ekg\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cp\u003eThe Honeywell 51401381-100 addresses the challenge of maintaining signal integrity in electrically \"noisy\" industrial environments. Its\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eEMI-resistant design\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eshields the 1 Mbps data bus from external interference, preventing packet loss during critical processor-to-gateway communication. The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eruggedized 5-slot architecture\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eallows engineers to scale their control capacity by mixing and matching interface cards without the need for additional external wiring between modules.\u003c\/p\u003e\n\u003cp\u003eFor facilities operating in extreme climates, this backpanel offers a superior\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ethermal range of −40 °C to +85 °C\u003c\/strong\u003e. This allows for reliable deployment in non-conditioned remote instrument buildings or high-heat process areas where standard electronics would fail. The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e24 VDC power architecture\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edelivers consistent current across all five slots, ensuring that power-hungry modules like History Modules or Universal Stations operate without voltage sag. Additionally, the compact\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e120 mm × 75 mm footprint\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efacilitates high-density mounting, allowing for the integration of multiple backpanel segments within a single standard control cabinet.\u003c\/p\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhich specific TDC 3000X modules can I install on this backpanel?\u003c\/strong\u003eThe 51401381-100 supports the full suite of TDC 3000X interface and processing cards, including Application Processors (AP), Network Gateways (NG), History Modules (HM), and Universal Station (US) interface cards.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow does the 1 Mbps data transfer rate impact system performance?\u003c\/strong\u003eThis rate provides the necessary bandwidth for real-time synchronization between control processors and gateways. It ensures that historical data logging and operator commands occur with minimal latency, maintaining the \"real-time\" responsiveness required by the TDC 3000X architecture.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs any special cooling required for a fully populated 5-slot backpanel?\u003c\/strong\u003eWhile the 51401381-100 itself handles temperatures up to +85 °C, always follow the airflow requirements of the specific modules you install. The backpanel's design promotes passive convection, but high-density configurations typically require standard cabinet ventilation to maintain the longevity of the installed processors.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan I link multiple 51401381-100 backpanels together?\u003c\/strong\u003eYes. In complex DCS layouts, multiple backpanels often reside within the same cabinet to support expanded gateway and history requirements. You must ensure the 24 VDC power supply is adequately rated to handle the cumulative load of all backpanels and their respective modules.\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":43748836376675,"sku":"51401381-100","price":320.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/303_640c993e-bde4-4b6a-b9e3-78c209a5007a.jpg?v=1775631762","url":"https:\/\/www.autocontrolglobal.com\/products\/application-processor-interconnect-hub-51401381-100-honeywell","provider":"AutoControl Global","version":"1.0","type":"link"}