{"product_id":"bently-nevada-78462-02-3300-series-8-channel-i-o-terminal","title":"Bently Nevada 78462-02 3300 Series 8-Channel I\/O Terminal","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 78462-02\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efunctions as a specialized XDUCR (Transducer) I\/O and Record Terminal within the industry-standard 3300 Series Monitoring System. This module provides the essential physical and logical interface between field-mounted transducers and the centralized monitoring rack. We supply this unit as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eoriginal hardware, engineered to acquire, process, and record high-fidelity vibration and position data. It plays a pivotal role in Turbine Supervisory Instrumentation (TSI), ensuring that critical rotating assets like compressors and generators operate within safe mechanical limits.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Detail\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada (Baker Hughes)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e78462-02\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3300 Series Monitoring System\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eXDUCR I\/O \u0026amp; Record Terminal\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Channels\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8 Transducer Input Channels\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOutput Channels\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4 Programmable Output Channels\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCommunication\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eEthernet, RS485\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e–40 °C to +85 °C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePower Supply\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24 V DC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e150 mm × 100 mm × 50 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2.0 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCompliance\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMeets API 670 Standards\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e100% Brand New Original\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePrecision Transducer Interfacing:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 78462-02 handles mixed signal types, managing both digital and analog data from proximity probes, velocity sensors, and accelerometers. This universal handling ensures seamless data flow for complex machinery diagnostics.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIntegrated Data Recording:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUnlike standard I\/O cards, this \"Record Terminal\" captures vital machinery signatures locally. This on-board recording capability provides a reliable data audit trail during transient events or system upsets, even if primary network communication fluctuates.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSuperior EMI Suppression:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIndustrial power generation environments produce intense electromagnetic interference. The 78462-02 utilizes advanced shielding and filtered inputs to prevent signal noise from corrupting transducer data, ensuring that \"Alert\" and \"Danger\" signals reflect true mechanical conditions.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRugged Thermal Engineering:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module operates consistently across an extreme temperature range of –40 °C to +85 °C. This resilience allows for installation in unprotected field enclosures near turbines or steam lines where standard electronics would fail.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProgrammable Relay Logic:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe unit features programmable logic for its 4 output channels. Engineers can configure these outputs to trigger specific auxiliary alerts or interlocking sequences based on the real-time condition of the rotating equipment.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation and Integration\u003c\/h3\u003e\n\u003cp\u003eMount the 78462-02 securely onto a standard DIN rail within the 3300 Series cabinet. Terminate transducer field wiring at the module's dedicated input terminals, ensuring proper shielding to maintain signal integrity. For remote monitoring and diagnostic uploads, utilize the Ethernet port to interface with System 1 or other high-level SCADA platforms. If integrating into a legacy network, the RS485 port provides a robust serial connection for long-distance data transmission.\u003c\/p\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the difference between the 78462-01 and the 78462-02?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 78462-01 focuses primarily on alarm relay outputs for the 3300 series. The 78462-02 serves as a more comprehensive XDUCR I\/O and Record Terminal, handling the direct interface and recording of transducer data.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this module support API 670 voting logic?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. When integrated into the 3300 Series rack, the 78462-02 supports the deterministic logic required by API 670 standards for machinery protection and automatic shutdown systems.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I access the recorded data from the terminal?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYou can retrieve recorded signatures and real-time monitoring data through the Ethernet or RS485 communication interfaces using Bently Nevada’s proprietary diagnostic software or compatible Modbus\/Ethernet drivers.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs this a surplus or used unit?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. We sell only\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New\u003c\/strong\u003e, original Bently Nevada hardware in its factory-sealed packaging. Each 78462-02 comes with a full 12-month warranty to ensure maximum reliability for your critical machinery.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":43751506411619,"sku":"78462-02","price":188.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/136.2_7dfefe77-b87d-45ba-9b73-fe333e7db576.jpg?v=1776236744","url":"https:\/\/www.autocontrolglobal.com\/products\/bently-nevada-78462-02-3300-series-8-channel-i-o-terminal","provider":"AutoControl Global","version":"1.0","type":"link"}