{"product_id":"bmxdrc0805-schneider-electric-modicon-x80-discrete-output-module","title":"BMXDRC0805 Schneider Electric Modicon X80 Discrete Output Module","description":"\u003ch2\u003eSchneider Electric BMXDRC0805 Modicon X80 Relay Output Module\u003c\/h2\u003e\n\u003cp\u003eThe Schneider Electric \u003cstrong\u003eBMXDRC0805\u003c\/strong\u003e is an 8-channel discrete relay output module designed for the Modicon X80 PLC platform. It provides isolated normally open (NO) and normally closed (NC) relay contact outputs operating across wide voltage ranges of 19 to 264 VAC and 5 to 150 VDC. This module allows the PLC to control field devices such as contactors, solenoid valves, and industrial actuators with configurable positive or negative output logic.\u003c\/p\u003e\n\u003ch3\u003eElectrical Characteristics and Load Ratings\u003c\/h3\u003e\n\u003cp\u003eThe module interfaces via a 40-way terminal block and provides galvanic isolation with insulation resistance exceeding 10 MΩ at 500 VDC. Output switching speed is specified with an activation time under 10 ms and a deactivation time under 13 ms.\u003c\/p\u003e\n\u003cp\u003eThermal switching capability varies with ambient operating conditions to prevent thermal stress on internal components:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e4 A\u003c\/strong\u003e continuous free-air thermal current per point at 40 deg C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e3 A\u003c\/strong\u003e continuous free-air thermal current per point at 50 deg C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e2 A\u003c\/strong\u003e continuous free-air thermal current per point at 60 deg C\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eMinimum switching requirements mandate at least 10 mA at 5 VDC to ensure reliable contact clean-up and signal continuity.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eBMXDRC0805\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eModicon X80\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eDiscrete Relay Output Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Outputs\u003c\/td\u003e\n\u003ctd\u003e8 channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Type\u003c\/td\u003e\n\u003ctd\u003eIsolated relay (NO \/ NC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Logic\u003c\/td\u003e\n\u003ctd\u003ePositive or negative\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated AC Voltage\u003c\/td\u003e\n\u003ctd\u003e24-240 VAC (19-264 VAC operating range)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated DC Voltage\u003c\/td\u003e\n\u003ctd\u003e24-125 VDC (5-150 VDC operating range)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork Frequency\u003c\/td\u003e\n\u003ctd\u003e50\/60 Hz (47-63 Hz limits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical Connection\u003c\/td\u003e\n\u003ctd\u003e40-way terminal block\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Switching Load\u003c\/td\u003e\n\u003ctd\u003e10 mA at 5 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResponse Time\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;= 10 ms (activation), \u0026lt;= 13 ms (deactivation)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThermal Current (Ith)\u003c\/td\u003e\n\u003ctd\u003e4 A at 40 deg C, 3 A at 50 deg C, 2 A at 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Dissipation\u003c\/td\u003e\n\u003ctd\u003e3.6 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Consumption\u003c\/td\u003e\n\u003ctd\u003e40 mA at 3.3 VDC, 101 mA at 24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation Resistance\u003c\/td\u003e\n\u003ctd\u003e\u0026gt; 10 MOhm at 500 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Platform\u003c\/td\u003e\n\u003ctd\u003eModicon X80 rack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandards Compliance\u003c\/td\u003e\n\u003ctd\u003eEN\/IEC 61131-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003cp\u003eFrequently Asked Questions\u003c\/p\u003e\n\u003cp\u003eQ: What are the current derating thresholds for the BMXDRC0805 outputs based on temperature? A: The module supports up to 4 A per channel at 40 deg C, which derates to 3 A at 50 deg C and 2 A at 60 deg C.\u003c\/p\u003e\n\u003cp\u003eQ: What is the minimum switching load required for accurate contact operation? A: The minimum switching requirement is 10 mA at 5 VDC to guarantee reliable contact switching.\u003c\/p\u003e","brand":"Schneider","offers":[{"title":"Default Title","offer_id":67884183584867,"sku":"BMXDRC0805","price":190.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/116_ed06c977-9d42-4312-9bfc-6e9d1ce62520.jpg?v=1793956424","url":"https:\/\/www.autocontrolglobal.com\/products\/bmxdrc0805-schneider-electric-modicon-x80-discrete-output-module","provider":"AutoControl Global","version":"1.0","type":"link"}