{"product_id":"brand-new-ge-is200aepbh1b-synchronous-generator-control","title":"Brand New GE IS200AEPBH1B Synchronous Generator Control","description":"\u003ch3\u003eProduct Details\u003c\/h3\u003e\n\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe GE IS200AEPBH1B serves as the central Exciter Power Board for the Mark VI Speedtronic turbine control platform. This module regulates power delivery and generates critical control signals for exciter circuits, maintaining the stable magnetic field required for synchronous generators. It acts as the high-reliability interface between the controller logic and the generator’s excitation system. We supply this board in\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efactory condition, ensuring that every capacitor and voltage regulator meets the stringent performance curves required for utility-scale power generation.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003eThe IS200AEPBH1B utilizes high-grade galvanic isolation and thermal management to ensure continuous operation in power plant environments.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAttribute\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eGE (General Electric)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel \/ Part Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIS200AEPBH1B \/ IS200AEPBH1BA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSystem Compatibility\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eGE Mark VI Turbine Control System\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24 VDC (Typically via Mark VI Rack)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eFunctional Output\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eRegulated Excitation Power \u0026amp; Control Signals\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eIsolation\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eGalvanic Isolation between Power\/Control Loops\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-20°C to +65°C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eHumidity Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5%–95% Non-condensing\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProtection\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOver-voltage, Over-current, Thermal Protection\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e30 × 20 × 5 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.5–2 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eStable Excitation Regulation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe IS200AEPBH1B provides precise voltage and current regulation to the exciter circuit. This stability prevents fluctuations in the generator’s output, protecting the power grid from frequency instability and reactive power swings.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSuperior Galvanic Isolation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThis board features robust isolation layers between the low-voltage control logic and the high-power exciter interface. This architectural barrier shields the central Mark VI processor from electrical noise, surges, and back-EMF generated by the excitation system.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIntegrated Safety Monitoring:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBuilt-in hardware interlocks monitor for over-current, over-voltage, and thermal runaway conditions. If the board detects an electrical fault, it immediately executes protective routines to prevent damage to the synchronous generator's windings.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModular Hot-Swap Capability:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe mechanical design supports hot-swappable replacement. Maintenance crews swap faulty modules without de-energizing the entire control rack, significantly reducing Mean Time to Repair (MTTR) and avoiding unnecessary turbine trips.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEMI\/RFI Hardening:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eGE constructs the IS200AEPBH1B with heavy-duty shielding to resist electromagnetic and radio frequency interference. This ensures signal purity in the high-EMF environments typical of steam and gas turbine compartments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the difference between IS200AEPBH1B and IS200AEPBH1BA?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe \"BA\" suffix typically denotes a specific hardware revision or grouping. The IS200AEPBH1BA remains fully backward compatible with the IS200AEPBH1B, providing identical electrical performance and physical mounting points within the Mark VI rack.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this board ship in original manufacturer packaging?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. Every IS200AEPBH1B we ship is\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New\u003c\/strong\u003e, unused, and arrives in its original GE factory anti-static packaging to ensure component integrity during transit via FedEx or DHL.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan this board be used in both gas and steam turbine systems?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The IS200AEPBH1B is a universal exciter power interface within the Mark VI platform. It controls the excitation systems for both gas and steam-driven synchronous generators across various power plant configurations.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat precautions are necessary during installation?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWhile the board supports hot-swapping, technicians must follow standard ESD (Electrostatic Discharge) procedures. Use a grounded wrist strap and ensure all ribbon cables and backplane connectors seat firmly to prevent intermittent signal loss or arcing.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":44098847604835,"sku":"IS200AEPBH1B","price":177.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/386._809c19be-edc1-418d-97b4-56104c041257.jpg?v=1775203181","url":"https:\/\/www.autocontrolglobal.com\/products\/brand-new-ge-is200aepbh1b-synchronous-generator-control","provider":"AutoControl Global","version":"1.0","type":"link"}