{"product_id":"brand-new-honeywell-51306669-175-turbomachinery-spm","title":"Brand New Honeywell 51306669-175 Turbomachinery SPM","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eHoneywell CC-TSP411\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(Part Number:\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e51306669-175\u003c\/strong\u003e) functions as a critical safety component within the Experion PKS architecture. This 4-channel Speed Protection Module (SPM) provides dedicated overspeed detection and machinery protection for high-value rotating assets including gas turbines, steam turbines, compressors, and large industrial motors. We supply this unit as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eoriginal hardware, Rev A. By utilizing independent monitoring channels and high-speed relay outputs, the CC-TSP411 ensures that turbomachinery remains within safe kinematic limits, preventing catastrophic mechanical failure through deterministic shutdown logic.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Detail\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHoneywell\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCC-TSP411\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e51306669-175\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModule Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSpeed Protection Module (SPM) \/ IOTA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eChannels\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4 Independent Monitoring Channels\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInputs\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHigh-speed Speed Sensor Inputs (Passive\/Active)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOutputs\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDedicated Relay Trip and Alarm Outputs\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePower Supply\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24 VDC Nominal (Max 10 W)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e–40 °C to +70 °C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eStorage Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e–40 °C to +85 °C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e63.5 × 124.46 × 307.34 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.8 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e100% Brand New Original (Rev A)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eQuad-Channel Redundancy \u0026amp; Independence:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe CC-TSP411 monitors four separate speed inputs simultaneously. Each channel operates with its own independent programmable setpoints for maximum speed and acceleration thresholds. This allows engineers to implement 2-out-of-3 (2oo3) or other voting logics to eliminate nuisance trips while maintaining a high Safety Integrity Level (SIL).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMillisecond Response Times:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEngineered for turbomachinery where milliseconds matter, the SPM detects overspeed conditions and triggers its mechanical relay trip outputs almost instantaneously. This rapid execution prevents shafts from reaching critical burst speeds during sudden load rejection events.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIntegrated Self-Diagnostics:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module executes continuous self-check functions and internal fault detection. If the SPM detects an internal failure or a loss of sensor signal integrity, it immediately triggers fault indications, allowing operators to address protection gaps before they compromise the machinery.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRuggedized for Extreme Environments:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWith an operational temperature rating spanning from –40 °C to +70 °C, the CC-TSP411 thrives in unconditioned turbine enclosures or remote pumping stations. The robust hardware design resists the intense vibrations and electromagnetic interference common in power generation facilities.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFlexible Sensor Compatibility:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module accepts signals from a wide variety of industrial speed sensors. Whether your system utilizes magnetic pickups or proximity probes, the CC-TSP411 processes these pulses into accurate RPM and acceleration data for real-time monitoring.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation and Configuration\u003c\/h3\u003e\n\u003cp\u003eMount the CC-TSP411 onto the standard Honeywell DIN rail IOTA (Input Output Termination Assembly) base. Connect your field speed sensors to the high-speed input terminals and integrate the relay trip outputs directly into the Emergency Shutdown (ESD) loop. Configuration occurs via the Experion PKS software suite, where you must define specific pulse-per-revolution counts and hysteresis values to ensure reliable protection without false signaling.\u003c\/p\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan I use the CC-TSP411 as a standalone speed controller?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe CC-TSP411 is primarily a protection module designed for overspeed detection and shutdown. While it provides accurate speed data, it should function as part of a comprehensive safety system alongside a primary governor or DCS controller.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the difference between this and a standard Digital Input module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eStandard DI modules lack the high-speed processing and frequency-to-analog conversion required for RPM monitoring. The CC-TSP411 features specialized circuitry to handle high-frequency pulse trains and dedicated hardware relays for safety-critical trips.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this module support acceleration-based trips?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. In addition to static overspeed setpoints, the CC-TSP411 allows you to program acceleration thresholds. This helps detect a \"runaway\" condition earlier than a standard speed trip, providing an extra layer of safety for high-inertia rotors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs this the latest Revision A version?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. We only supply\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eoriginal Honeywell hardware. This specific listing is for the Rev A 51306669-175, ensuring compatibility with the latest Experion PKS firmware and IOTA requirements.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":44118924886115,"sku":"CC-TSP411","price":320.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/347_6e356488-e59e-407b-9654-c2d467b1f7c7.jpg?v=1776241483","url":"https:\/\/www.autocontrolglobal.com\/products\/brand-new-honeywell-51306669-175-turbomachinery-spm","provider":"AutoControl Global","version":"1.0","type":"link"}