{"product_id":"buy-bently-nevada-1701-06-original-141377-01-terminal-base","title":"Buy Bently Nevada 1701\/06 | Original 141377-01 Terminal Base","description":"\u003ch2\u003eProduct Details\u003c\/h2\u003e\n\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 1701\/06\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(Part Number:\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e141377-01\u003c\/strong\u003e) functions as a specialized\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIsolator Terminal Base (ITB)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ewithin the Bently Nevada modular machinery protection ecosystem. It provides the essential physical and electrical interface for transducer signals, specifically designed to host\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e170180 Transducer I\/O\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e170190 Dual Galvanic Isolator\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003emodules. By establishing high-integrity electrical isolation between field transducers and the machine ground, the 1701\/06 eliminates parasitic noise and ground loops. This ensures that the monitoring system receives only pure, undistorted vibration data for critical diagnostic analysis.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Details\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1701\/06\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e141377-01\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIsolator Terminal Base (ITB)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCompatible Modules\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e170180 Transducer I\/O, 170190 Dual Galvanic Isolator\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eIsolation Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eGalvanic \/ Electrical Ground Loop Elimination\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSecure Panel Mount\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDimensions (W x H x D)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e127 mm x 203.2 mm x 50.8 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.6 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUnited States\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e100% Brand New in Original Packaging\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eGround Loop Eradication:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 1701\/06 architecture breaks the electrical path between the machinery casing and the monitoring instrument. This prevents stray currents from contaminating vibration waveforms, which is critical for identifying subtle bearing faults or shaft cracks.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModular Integration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThis base acts as the foundation for the 1701 series. It allows engineers to \"hot-swap\" isolator modules without disturbing the field wiring connected to the terminal base, significantly reducing maintenance downtime.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRuggedized Signal Routing:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 141377-01 features heavy-duty terminal blocks that secure large-gauge field wiring. The robust panel-mount design resists the high-frequency vibrations often found in local instrument cabinets near turbines and compressors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEnhanced Signal Fidelity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBy providing a stable, isolated reference point, the ITB ensures that sensitive proximity probe and accelerometer signals maintain their voltage-to-displacement ratios across long cable runs.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCompact Footprint:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eMeasuring only 50.8 mm in depth, the base fits easily into shallow junction boxes or high-density control panels, optimizing space in crowded industrial environments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: Is the 1701\/06 141377-01 a new or refurbished part?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA1: We supply this unit as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New and Original Bently Nevada\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003estock. Every base ships in its original factory packaging and includes a full 12-month warranty from the date of purchase.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: Which specific modules can I plug into this terminal base?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA2: The 1701\/06 is specifically keyed and wired to support\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e170180 Transducer I\/O modules\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e170190 Dual Galvanic Isolator modules\u003c\/strong\u003e. It ensures proper pin alignment and electrical continuity for these specific components.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: Does the terminal base require an independent power supply?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA3: No. The 1701\/06 141377-01 is a passive terminal base that routes power and signals between the plugged-in modules and the field sensors. The active modules (like the 170190) handle the electrical isolation and signal conditioning.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ4: How does this base prevent electrical noise in the vibration system?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA4: It provides the physical mounting points for galvanic isolators. These isolators use transformers or opto-isolators to pass the signal without a direct metallic connection, effectively \"floating\" the sensor signal away from noisy machine grounds.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":43790578384995,"sku":"1701\/06 141377-01","price":188.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/238.2_1e659c79-ba66-4327-a264-753b093f386e.jpg?v=1775785783","url":"https:\/\/www.autocontrolglobal.com\/products\/buy-bently-nevada-1701-06-original-141377-01-terminal-base","provider":"AutoControl Global","version":"1.0","type":"link"}