{"product_id":"cc-tcnt01-honeywell-industrial-network-interface-terminal-block","title":"CC-TCNT01 Honeywell Industrial Network Interface Terminal Block","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe Honeywell 51308307-175 (Model Reference: CC-TCNT01) operates as a high-density, specialized Input\/Output Termination Assembly (IOTA) designed exclusively for the Honeywell C300 controller subsystem within the Experion PKS framework. This foundational hardware interface establishes the mechanical and electrical termination plane where field device wiring connects directly to the processing backbone. Control engineers install this block within cabinet enclosures to route, secure, and condition vital supervisory communication lines and process I\/O paths, ensuring uninterrupted signal exchange between downstream field assets and the primary C300 processing engine.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Value\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHoneywell\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e51308307-175\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eAlternate Part Reference\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCC-TCNT01\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eComponent Classification\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eController Input\/Output Termination Assembly (IOTA)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSystem Compatibility\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHoneywell C300 Controller \/ Experion PKS Platform\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePrimary Core Function\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eEstablishes physical wiring interface for system I\/O loops\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCommunication Support\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFacilitates deterministic controller peer-to-peer data paths\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePhysical Module Profile\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e22 cm x 12 cm x 5.3 cm (W x H x D)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNet Structural Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.22 kg (0.49 lbs)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eEnclosure Installation Matrix\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSupports vertical panel surface or multi-slot rack mounting\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eGlobal Industry Approvals\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCE marked, TUV certified, UL508 listed, CSA validated\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eEngineering Country of Origin\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSourcing Supply Profile\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e100% Brand New and Original in Factory Packing\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003ch3\u003eHigh-Density Footprint Maximizes Tight Cabinet Spatial Layouts\u003c\/h3\u003e\n\u003cp\u003eThe CC-TCNT01 uses a compact, streamlined physical profile measuring 22 cm x 12 cm. This spatial efficiency allows marshalling panel builders to maximize the number of active terminal points inside standard-sized control enclosures. By condensing the electrical termination matrix down to a lightweight 0.22 kg block, this assembly reduces total panel clutter, minimizes structural weight overhead, and leaves ample room for clean wire tray routing and optimal convection cooling channels.\u003c\/p\u003e\n\u003ch3\u003eStructural Terminal Isolation Safeguards Peer-to-Peer Networks\u003c\/h3\u003e\n\u003cp\u003eThe electrical trace layout of the 51308307-175 embeds transient isolation barriers that safeguard critical peer-to-peer data lines running between co-located C300 controllers. In heavy industrial environments like petrochemical refineries or power stations, stray inductive spikes from massive switchgear can introduce deadly voltage ripples into shared communications pathways. This IOTA isolates and grounds out field-induced electrical line disturbances right at the landing screws, keeping localized network faults from degrading high-speed controller-to-controller synchronization loops.\u003c\/p\u003e\n\u003ch3\u003eFixed-Screw Wire Clamping Shakes Off Continuous Mechanical Vibration\u003c\/h3\u003e\n\u003cp\u003eContinuous structural vibrations from adjacent heavy equipment like compression pumps, fans, and cooling towers can cause loose terminal connections over time. The 51308307-175 features robust, industrial-grade screw-terminal clamping collars that lock the incoming field conductors firmly in place. This heavy-duty connection style maintains continuous metal-to-metal contact pressure under constant mechanical strain, preventing intermittent open-circuit faults and eliminating the erratic signal dropouts that frequently plague lesser-quality tension clamp blocks.\u003c\/p\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eWhat specific function does the 51308307-175 serve regarding peer-to-peer communications?\u003c\/p\u003e\n\u003cp\u003eThe CC-TCNT01 provides specialized, high-integrity physical bus links that route peer-to-peer data lines cleanly between multiple adjacent C300 controller nodes. This design ensures that coordinated interlock signals, safety trip commands, and shared process variables move between separate controller processors across the local network without suffering signal attenuation or transmission delay.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDoes this assembly support both field panel mounting and vertical rack configurations?\u003c\/p\u003e\n\u003cp\u003eYes. The structural mold of the 51308307-175 features universal mounting integration paths. Technicians can fasten the IOTA directly onto flat back-panels inside local control boxes, or snap it into standardized vertical cabinet channels depending on the specific layout design and space constraints of your facility's marshalling yard.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan an operator swap out an adjacent module without damaging the 51308307-175 wiring?\u003c\/p\u003e\n\u003cp\u003eYes. Because the 51308307-175 acts as a dedicated permanent field termination assembly, all field wire harnesses remain securely fastened to the terminal screws during routine system upgrades. You can service or replace the docked C300 processing modules or adjacent interface cards without disconnecting your field wiring, speeding up system maintenance and removing the risk of landing wires on the wrong terminals during reassembly.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":43850083369059,"sku":"51308307-175","price":320.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/267_26b0bea0-511a-4722-988d-a3a58fddcf2c.jpg?v=1763946269","url":"https:\/\/www.autocontrolglobal.com\/products\/cc-tcnt01-honeywell-industrial-network-interface-terminal-block","provider":"AutoControl Global","version":"1.0","type":"link"}