{"product_id":"cc-tdil01-honeywell-experion-series-c-digital-input-iota","title":"CC-TDIL01 Honeywell Experion Series C Digital Input IOTA","description":"\u003ch2\u003eHoneywell CC-TDIL01 Experion PKS Series C Digital Input IOTA\u003c\/h2\u003e\n\u003cp\u003eConfigured for discrete field signal acquisition in Honeywell Experion PKS platforms, the \u003cstrong\u003eHoneywell CC-TDIL01\u003c\/strong\u003e (\u003cstrong\u003eCC-TDIL01\u003c\/strong\u003e) Digital Input Input\/Output Terminal Assembly provides direct physical\/electrical execution.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eCC-TDIL01 \/ 51308386-175\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.45 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e127 mm x 89 mm x 32 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-20 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e24 VDC nominal supply (18 to 30 VDC range)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Platform\u003c\/td\u003e\n\u003ctd\u003eHoneywell Experion PKS \/ C300 Series C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Input Channels\u003c\/td\u003e\n\u003ctd\u003e32 channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Range\u003c\/td\u003e\n\u003ctd\u003e0 to 30 VDC (On-State \u0026gt;= 12 VDC, Off-State \u0026lt;= 5 VDC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Current Draw\u003c\/td\u003e\n\u003ctd\u003e7 to 10 mA per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGalvanic Isolation\u003c\/td\u003e\n\u003ctd\u003eChannel-to-channel and channel-to-system isolation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCircuit Protection\u003c\/td\u003e\n\u003ctd\u003eInternal field-wiring short-circuit protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible Modules\u003c\/td\u003e\n\u003ctd\u003eCC-PDIL01 \/ CC-PDIS01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Format\u003c\/td\u003e\n\u003ctd\u003e9-inch Series C IOTA carrier rack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003e4-20 mA HART Loop Protocol \u0026amp; Channel Isolation\u003c\/h3\u003e\n\u003cp\u003eEngineers integrate the assembly into distributed control networks requiring strict separation between high-voltage field wiring and sensitive processor buses. Channel-to-channel galvanic isolation blocks high common-mode voltage spikes and suppresses electromagnetic noise in high-density panel configurations. The board supports selectable internal or external 24 VDC field sensing power, while internal diagnostic circuitry continuously evaluates terminal state transitions and flags wiring shorts before loop power failure occurs.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the CC-TDIL01 require a companion electronic module to process digital inputs?\u003c\/p\u003e\n\u003cp\u003eA: Yes, the unit functions as a terminal assembly and must be paired with a CC-PDIL01 standard digital input module or a CC-PDIS01 Sequence-of-Events (SOE) module.\u003c\/p\u003e\n\u003cp\u003eQ: How does the hardware distinguish between ON and OFF signal states?\u003c\/p\u003e\n\u003cp\u003eA: Channel circuitry registers an ON state when field voltage reaches or exceeds 12 VDC, and registers an OFF state when voltage drops to or below 5 VDC.\u003c\/p\u003e\n\u003cp\u003eQ: Can field channels be powered via external voltage sources?\u003c\/p\u003e\n\u003cp\u003eA: Yes, the IOTA hardware jumpers allow configuration for either internal bus-supplied 24 VDC sensing or external field power loop excitation.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eMount the assembly onto the 9-inch Series C carrier rack inside a grounded control enclosure. Ensure a minimum vertical clearance of 50 mm surrounding the board to support natural convection cooling up to the 60 deg C operating threshold. Connect incoming field wiring to the designated terminal block screw pairs, torquing screws to 0.5 Nm. Route signal lines separately from high-voltage AC cables and ground all shielded cables directly to the enclosure earth bus bar to eliminate noise coupling.\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":43856047439971,"sku":"CC-TDIL01","price":320.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/214_76ac3563-13fb-4af2-a999-6a4138a0f01c.jpg?v=1764121466","url":"https:\/\/www.autocontrolglobal.com\/products\/cc-tdil01-honeywell-experion-series-c-digital-input-iota","provider":"AutoControl Global","version":"1.0","type":"link"}