{"product_id":"cc-tfe021-honeywell-experion-pks-fiber-optic-extender","title":"CC-TFE021 Honeywell Experion PKS Fiber Optic Extender","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eHoneywell CC-TFE021\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eserves as a specialized Fiber Optic Extender Input Output Termination Assembly (IOTA) for the Experion Process Knowledge System (PKS). This module facilitates high-speed, real-time Ethernet communication between central controllers and distributed field hardware. By converting electrical Ethernet signals into optical signals, the CC-TFE021 bridges long-distance gaps that exceed the limitations of standard copper cabling. We supply this unit as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New and Original\u003c\/strong\u003e, ensuring absolute network stability for large-scale industrial process control environments.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Details\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCC-TFE021\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFiber Optic Extender IOTA Module\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSystem Compatibility\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHoneywell Experion PKS\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCommunication Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eEthernet over Fiber\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e–20°C to +60°C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMounting Options\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDIN Rail or Panel Mount\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDimensions (W x H x D)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e110 mm × 150 mm × 50 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.6 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCertifications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCE, UL, CSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eImmunity to Electromagnetic Interference (EMI):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe CC-TFE021 utilizes fiber optic transmission to eliminate the risk of electrical noise, ground loops, and interference. This makes the module indispensable in environments with high-voltage equipment, heavy motors, or variable frequency drives (VFDs) where copper communication typically fails.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eExtended Network Reach:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUnlike standard Ethernet cables limited to 100 meters, this fiber optic extender maintains signal integrity across kilometers of plant infrastructure. It allows for the deployment of remote I\/O racks in decentralized locations while keeping the central processor in a secure control room.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHardware-Level Reliability:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe robust design handles the thermal stresses of industrial environments (–20°C to +60°C). It integrates seamlessly into the Experion PKS architecture, appearing as a transparent communication link that requires minimal configuration compared to third-party media converters.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFlexible Installation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe compact 110mm width and support for both DIN rail and panel mounting allow engineers to fit the module into crowded marshalling cabinets or specialized enclosures with ease.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhy should I use the CC-TFE021 instead of a standard media converter?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe CC-TFE021 is a native Honeywell IOTA designed specifically for the Experion PKS ecosystem. It provides superior diagnostic integration and environmental hardening that generic commercial media converters cannot match, ensuring your control network remains compliant with industrial standards.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this module require external power?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe CC-TFE021 integrates into the Experion power distribution scheme via the IOTA backplane connections. It typically draws 24 VDC power through the standard rack interface, simplifying wiring and reducing potential failure points.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat type of fiber optic cable does the CC-TFE021 support?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe module generally supports multi-mode or single-mode fiber depending on the specific SFP or integrated transceiver configuration. Please consult your system design documentation to match the module with your existing fiber infrastructure.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs this unit compatible with C300 controllers?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes, the CC-TFE021 is fully compatible with the Honeywell C300 controller series and associated Experion network hardware, facilitating high-speed data exchange across the FTE (Fault Tolerant Ethernet) layer.\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":43796424392803,"sku":"CC-TFE021","price":320.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/585.jpg?v=1761643877","url":"https:\/\/www.autocontrolglobal.com\/products\/cc-tfe021-honeywell-experion-pks-fiber-optic-extender","provider":"AutoControl Global","version":"1.0","type":"link"}