{"product_id":"ci522a-abb-profibus-dp-master-slave-interface-3bse018283r1","title":"CI522A ABB Profibus DP Master\/Slave Interface 3BSE018283R1","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe CI522A 3BSE018283R1 provides the hardware interface required to connect an AC 800M controller to a Profibus DP network. It operates as either a Class 1 or Class 2 Master, supporting up to 126 slave devices with data rates reaching 12 Mbps. We provide this module as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New and Original\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ein factory packing, backed by a 12-month warranty to guarantee performance in mission-critical automation environments.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCI522A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3BSE018283R1 (3BSE018283R0001)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProtocol\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eProfibus DP-V0 and DP-V1\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBaud Rate\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e9.6 kbps to 12 Mbps (Auto-detection)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMax Devices\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e126 Slave Stations\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInterface\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eRS-485 (via DB9 connector)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eIsolation\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e500 VAC (Channel to Backplane)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0°C to +60°C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e120 mm (W) x 265 mm (D) x 27 mm (H)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePower Supply\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eInternal via backplane\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cp\u003eThe CI522A 3BSE018283R1 addresses specific industrial networking challenges through hardware-level optimization and deep system integration:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAcyclic Communication (DP-V1) Support:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBeyond standard cyclic data, the CI522A manages acyclic (Class 2) messaging. This allows engineers to perform remote parameterization, maintenance, and detailed diagnostics of field devices without interrupting the primary control cycle.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHot-Swap Functionality:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module supports \"Hot Configuration in Run\" (HCIR) and physical hot-swapping. Maintenance teams replace or add modules without powering down the AC 800M controller, effectively eliminating production downtime.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDeterministic Network Performance:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe CI522A offloads communication processing from the main CPU. This ensures that even under a full load of 126 devices at 12 Mbps, the controller maintains consistent scan times for critical logic execution.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRedundancy Capabilities:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWhen paired with the CI524A, the system supports dual-bus redundancy. This architecture ensures that a single cable break or bus fault does not result in a loss of signal from the distributed I\/O or motor drives.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the CI522A require specific software for configuration?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. You configure the CI522A through ABB Control Builder M. The software uses GSD (General Station Description) files to define the characteristics of the connected Profibus slaves, allowing for drag-and-drop integration into the System 800xA hardware tree.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan I use the CI522A as a Profibus Slave?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWhile primarily used as a Master (Class 1 or 2) to control field devices, the CI522A hardware supports slave functionality. This allows the AC 800M controller to act as a subordinate station to a higher-level PLC or DCS system if required by the network topology.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the significance of the LED indicators on the front panel?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe CI522A includes dedicated LEDs for \"Run,\" \"Fault,\" and \"Bus Status.\" These provide immediate visual diagnostics: the \"Fault\" LED indicates internal hardware errors, while the \"Bus\" LED flashes or changes color to signal configuration mismatches or physical layer interruptions on the Profibus line.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs this module compatible with non-ABB Profibus devices?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAbsolutely. Because the CI522A adheres strictly to the Profibus DP-V0\/V1 standards, it communicates with any third-party Profibus-certified device, including Siemens drives, Endress+Hauser sensors, and various pneumatic manifolds.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":44170559455331,"sku":"CI522A 3BSE018283R0001","price":420.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/475._b71cb4ab-2b48-4abc-9c56-ff5a33d9fce3.jpg?v=1778485745","url":"https:\/\/www.autocontrolglobal.com\/products\/ci522a-abb-profibus-dp-master-slave-interface-3bse018283r1","provider":"AutoControl Global","version":"1.0","type":"link"}