{"product_id":"ci853k01-3bse018103r3-abb-s800-communication-interface-module","title":"CI853K01 3BSE018103R3 ABB S800 Communication Interface Module","description":"\u003ch2\u003eABB CI853K01 Communication Interface Module\u003c\/h2\u003e\n\u003cp\u003eConfigured for serial data exchange in S800 I\/O distributed systems, the \u003cstrong\u003eABB 3BSE018103R3\u003c\/strong\u003e (\u003cstrong\u003eCI853K01\u003c\/strong\u003e Communication Interface Module) provides direct physical execution of RS-232 serial communication protocols between field devices and AC 800M controllers.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e3BSE018103R3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eAs specified per batch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e102 x 119 x 45 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 deg C to +55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e2.5 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Protocols\u003c\/td\u003e\n\u003ctd\u003eCOMLI (Master\/Slave), Modbus RTU (Master)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003ePLC Control and Deterministic Performance\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eCI853K01\u003c\/strong\u003e manages asynchronous serial data transmission, supporting both half-duplex COMLI and Modbus RTU standards. Integration within the AC 800M environment relies on optimized backplane bus communication velocity; the module manages data addressing and diagnostic reporting to ensure timing synchronization with the controller logic. Firmware flash compatibility allows for functional updates to protocol handling, while the module supports I\/O density scaling by functioning as a serial gateway on the Modulebus. The internal processing architecture facilitates hot-swap operations, permitting the replacement of units without disrupting the host rack's backplane logic or requiring a system-wide power cycle.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the CI853K01 support redundant configurations for all protocols?\u003c\/p\u003e\n\u003cp\u003eA: Module redundancy is supported for general interface operations; however, Modbus RTU mode does not support redundant configuration on this module.\u003c\/p\u003e\n\u003cp\u003eQ: Can the serial link distance be extended beyond standard RS-232 limits?\u003c\/p\u003e\n\u003cp\u003eA: Yes, signal range can be extended to several kilometers by utilizing external fiber optic converters connected to the module's RS-232 serial ports.\u003c\/p\u003e\n\u003cp\u003eQ: What are the master\/slave limitations for the supported protocols?\u003c\/p\u003e\n\u003cp\u003eA: The CI853K01 supports both Master and Slave modes for the COMLI protocol, whereas Modbus RTU is restricted to Master mode only.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Seat the module into the designated S800 I\/O baseplate slot. Verify the mechanical engagement of the locking mechanism to ensure stable contact with the backplane bus.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring:\u003c\/strong\u003e Connect serial devices using shielded RS-232 cabling. Ensure the cable drain wire is terminated to the designated ground point on the baseplate to mitigate noise coupling.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding:\u003c\/strong\u003e Maintain a low-impedance connection between the DIN-rail baseplate and the cabinet ground bus. Keep serial communication lines physically separated from high-voltage AC power cabling to prevent electromagnetic interference (EMI).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eValidation:\u003c\/strong\u003e Configure the serial port parameters (baud rate, parity, stop bits) within the control application to match the field device. Utilize the module's diagnostic registers to confirm packet transmission success before enabling active control loops.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":44314111082595,"sku":"CI853K01 3BSE018103R3","price":650.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/167.1_fa79d370-51e3-49c7-b5d5-6f22944ee897.jpg?v=1783068494","url":"https:\/\/www.autocontrolglobal.com\/products\/ci853k01-3bse018103r3-abb-s800-communication-interface-module","provider":"AutoControl Global","version":"1.0","type":"link"}