{"product_id":"ci854k01-abb-ac-800m-profibus-dp-v1-master-kit-3bse025961r1","title":"CI854K01 ABB AC 800M PROFIBUS DP-V1 Master Kit 3BSE025961R1","description":"\u003ch2\u003eABB CI854K01 3BSE025961R1 AC 800M PROFIBUS DP-V1 Interface Kit\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eABB CI854K01\u003c\/strong\u003e (order number \u003cstrong\u003e3BSE025961R1\u003c\/strong\u003e) is a PROFIBUS DP-V1 master communication interface kit designed for ABB AC 800M controllers within the System 800xA control platform. The kit provides master connectivity to integrate PROFIBUS field devices—such as remote I\/O units, variable speed drives, and motor controllers—into the controller network via the CEX-Bus.\u003c\/p\u003e\n\u003ch3\u003eKit Components and Hardware Configuration\u003c\/h3\u003e\n\u003cp\u003eThe CI854K01 kit includes one CI854 communication module and one TP854 baseplate (connection unit). The assembly features a standard DB9 female connector for field bus attachment and operates as a PROFIBUS DP Master Class 1 and Class 2 controller across transmission speeds ranging from 9.6 kbit\/s to 12 Mbit\/s. Each segment supports up to 32 nodes without repeaters and incorporates galvanic isolation for robust signal integrity.\u003c\/p\u003e\n\u003ch3\u003ePower and Installation Requirements\u003c\/h3\u003e\n\u003cp\u003eThe module operates from the internal 24 VDC bus supply, drawing a typical current of 190 mA (240 mA maximum) with a typical power dissipation of 4.6 W. Visual diagnostics are provided on the front panel through RUN, Fault, RXA, RXB, and Primary\/Dual status LEDs. Designed for controller rail mounting, the compact IP20 enclosure measures 59 mm wide by 185 mm high by 127.5 mm deep and is certified to UL 508 and UL 60079-15 safety standards.\u003c\/p\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eCI854K01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrder Number\u003c\/td\u003e\n\u003ctd\u003e3BSE025961R1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eAC 800M \/ System 800xA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eCommunication Interface Kits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eKit Components\u003c\/td\u003e\n\u003ctd\u003eCI854 Communication Module, TP854 Connection Baseplate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Protocol\u003c\/td\u003e\n\u003ctd\u003ePROFIBUS DP \/ DP-V1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Mode\u003c\/td\u003e\n\u003ctd\u003eDP Master Class 1 and Class 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInternal Bus Interface\u003c\/td\u003e\n\u003ctd\u003eCEX-Bus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransmission Speed\u003c\/td\u003e\n\u003ctd\u003e9.6 kbit\/s to 12 Mbit\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFieldbus Connector\u003c\/td\u003e\n\u003ctd\u003eDB9 Female\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Node Capacity\u003c\/td\u003e\n\u003ctd\u003e32 nodes per segment (without repeater)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGalvanic Isolation\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Consumption\u003c\/td\u003e\n\u003ctd\u003e190 mA typical, 240 mA maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Dissipation\u003c\/td\u003e\n\u003ctd\u003e4.6 W typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e+5 to +55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Rating\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x H x D)\u003c\/td\u003e\n\u003ctd\u003e59 mm x 185 mm x 127.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.7 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertifications\u003c\/td\u003e\n\u003ctd\u003eUL 508, UL 60079-15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReplacement Model\u003c\/td\u003e\n\u003ctd\u003eCI854AK01 (requires Control Software v3.2\/1 or later)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003cp\u003eFrequently Asked Questions\u003c\/p\u003e\n\u003cp\u003eQ: What components are included in the ABB CI854K01 kit assembly? A: The kit contains the CI854 PROFIBUS DP-V1 communication module and the matching TP854 baseplate (connection unit) required for mounting and connection to the controller CEX-Bus.\u003c\/p\u003e\n\u003cp\u003eQ: Can the CI854K01 be replaced by the newer CI854AK01 module? A: Yes, the CI854AK01 serves as a replacement kit, provided the AC 800M system is running Control Software version 3.2\/1 or later.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":43780123754595,"sku":"CI854K01","price":676.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/124.2_ffac5df7-8c64-4f25-92f4-b75f9bb02732.jpg?v=1760516376","url":"https:\/\/www.autocontrolglobal.com\/products\/ci854k01-abb-ac-800m-profibus-dp-v1-master-kit-3bse025961r1","provider":"AutoControl Global","version":"1.0","type":"link"}