{"product_id":"communication-card-ge-ds200tcqcg1bfe-mark-v","title":"Communication Card | GE DS200TCQCG1BFE Mark V","description":"\u003ch2\u003eGE DS200TCQCG1BFE Mark V Speedtronic Quad Communication Board\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eGE DS200TCQCG1BFE\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eDS200TCQC\u003c\/strong\u003e Quad Communication Board, operates as a dedicated hardware component for signal routing, communication synchronization, and peripheral data exchange within Mark V Speedtronic platforms.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eBase Model\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eBoard Identifier\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eFunctional Revision\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eArtwork \/ Firmware Revision\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDS200\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eTCQC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eG1\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eBFE\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eDS200TCQCG1BFE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE (General Electric)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.254 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e330 x 280 x 50 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eDependent on backplane load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eQuad Communication Board (TCQC \/ RST Overflow Board)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC (from system PSU)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n\u003ctd\u003eGE Mark V Turbine Control System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhysical Form Factor\u003c\/td\u003e\n\u003ctd\u003eStandard Mark V rack size board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHardware Protection\u003c\/td\u003e\n\u003ctd\u003eIntegrated fuse protection with monitoring circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiagnostic Display\u003c\/td\u003e\n\u003ctd\u003eOnboard status and fault indication LEDs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterface Topology\u003c\/td\u003e\n\u003ctd\u003eBackplane bus and serial communication ports\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eDeterministic Backplane Communications \u0026amp; Network Execution\u003c\/h3\u003e\n\u003cp\u003eThe board manages quad-channel communication routing across the Mark V backplane bus to ensure real-time data execution. Embedded logic handles communication synchronization and local signal routing without increasing processor latency. Onboard diagnostic LEDs continuously monitor bus traffic and power status, while hardware jumpers allow technicians to adjust serial line timing and communication parameters.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Can the DS200TCQCG1BFE board be swapped while the Mark V rack is energized?\u003c\/p\u003e\n\u003cp\u003eA: No. Operating personnel must completely isolate system power before extracting or seating the board. Hot-swapping risks damaging sensitive backplane bus components and corrupting active communication channels.\u003c\/p\u003e\n\u003cp\u003eQ: How are communication timing and address settings configured on the DS200TCQCG1BFE?\u003c\/p\u003e\n\u003cp\u003eA: Onboard jumpers and switches control serial line timing, address assignment, and communication routing parameters. Technicians must match these jumper configurations to the system engineering drawings prior to installation.\u003c\/p\u003e\n\u003cp\u003eQ: What indicates an internal electrical protection fault on the board?\u003c\/p\u003e\n\u003cp\u003eA: Integrated onboard fuses protect the 24 VDC distribution paths. A blown fuse triggers an illuminated diagnostic LED on the board edge, signaling a circuit fault to maintenance personnel.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDisconnect all primary power supplies feeding the Mark V card cage before beginning replacement procedures.\u003c\/li\u003e\n\u003cli\u003eWear an ESD grounding wrist strap attached to the cabinet ground stud to prevent electrostatic damage during module handling.\u003c\/li\u003e\n\u003cli\u003eVerify that all onboard jumper positions match the exact configuration of the replaced board before inserting it into the rack.\u003c\/li\u003e\n\u003cli\u003eAlign the board along the card cage guide rails and seat it firmly into the backplane connector before tightening the retention hardware.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":44437608398947,"sku":"DS200TCQCG1BFE","price":120.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/435._f6c6ecbb-33b9-439a-927a-254859a8d0ad.jpg?v=1785830323","url":"https:\/\/www.autocontrolglobal.com\/products\/communication-card-ge-ds200tcqcg1bfe-mark-v","provider":"AutoControl Global","version":"1.0","type":"link"}